Sponsored Content
Full Discussion: VIO SEA Adapters
Operating Systems AIX VIO SEA Adapters Post 302842707 by ibmtech on Friday 9th of August 2013 05:23:37 PM
Old 08-09-2013
Ok,
When you click "View/Modify Host Ethernet Adapters", you are seeing two HEA's, now check the one on the top and select properties,
under general tab check mark the option called "Allow virtual Ethernet bridging" click ok and do the same for the other HEA adapter.

Then go to "Virtual Ethernet Bridge" and you will see a adapter.

Basically you are bridging two HEA adapters for redundancy.
This User Gave Thanks to ibmtech For This Post:
 

7 More Discussions You Might Find Interesting

1. AIX

20EE0008 : No adapters found Adapter, Riser, System Bd.

Hello, When I try to upgrade AIX from 5.1 to 5.3 I get this error message 20EE0008 : No adapters found Adapter, Riser, System Bd. Anyone know anything about it ? (1 Reply)
Discussion started by: filosophizer
1 Replies

2. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. Red Hat

Designating Default Gateway for multiple networks/adapters

Hi I have 4 NIC's connected to my RHEL 5.3 server. Two on one subnet creating bond0, and two on a second subnet which create bond1. Both bonds are set to use DHCP to obtain IP addresses. Here is the config file for ifcfg-bond0: DHCP_HOSTNAME=rrnltshckvmx001 DEVICE=bond0 BOOTPROTO=dhcp... (2 Replies)
Discussion started by: Padow
2 Replies

4. AIX

SEA

Hi all, I set up the following configuration on my system: - An LPar with a virtual adapter, first one with a vlan id=703 and id port=13. - The first adapter have to connect to a VIOS in which i configured an SEA. So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Discussion started by: idro
0 Replies

5. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

6. Windows & DOS: Issues & Discussions

Order of Adapters in Windows 7

I am trying to get my boss' ipad to print on our local printers, and rapidly coming to loathe the product. After several false starts I'm attempting to use the free WePrint application, running on a Windows machine, to "forward" our printers from it to the ipad over the local network. I've hit... (2 Replies)
Discussion started by: Corona688
2 Replies

7. AIX

VIOS - fibre adapters not seeing luns

Hi guys, I've been trying to tackle this issue for days and I'm stumped. Hopefully someone can give more light on what else I can do. I have a p7 series box, with dual VIOS and 10 lpars and everything was working fine until I had to move the box to another location in the data centre. Ensured... (16 Replies)
Discussion started by: aixkidbee
16 Replies
scconf_transp_adap_ge(1M)				  System Administration Commands				 scconf_transp_adap_ge(1M)

NAME
scconf_transp_adap_ge - configure the Gigabit Ethernet (ge) transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure ge adapters as cluster transport adapters. These adapters can only be used with transport type dlpi. The ge adapter connects to a transport switch or to another ge adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ge(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ge(1M)
All times are GMT -4. The time now is 09:38 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy