Sponsored Content
Special Forums Hardware Filesystems, Disks and Memory Help needed! Raid 5 failure on a Debian System Post 302792705 by jonlisty on Thursday 11th of April 2013 12:43:02 AM
Old 04-11-2013
Help needed! Raid 5 failure on a Debian System

Hello!

I have a 4-disc Raid 5 server running Open Media Vault (Debian). The other day, it disappeared from OMV, which was reporting 3 drives failed. Panic Stations. However, using MDADM I can get info from 3 of the drives which suggests they are functioning ok (info below). The remaining 4th drive doesn't give anything back via mdadm --examine. Any ideas how I can rebuild the drive without destroying the data? According to what I have read, as the three apparently working drives all have the same events number (103), it is fairly likely the data is intact on them - but how to I rebuild?

Thanks my lovelies!

Jon

/dev/sdf:
Magic : a92b4efc
Version : 1.2
Feature Map : 0x0
Array UUID : dc344271:82f55bd0:fcfd0e16:a2a60bc8
Name : TTVServer:TTV2 (local to host TTVServer)
Creation Time : Mon Jan 7 11:03:39 2013
Raid Level : raid5
Raid Devices : 4

Avail Dev Size : 5860531120 (2794.52 GiB 3000.59 GB)
Array Size : 17581590528 (8383.56 GiB 9001.77 GB)
Used Dev Size : 5860530176 (2794.52 GiB 3000.59 GB)
Data Offset : 2048 sectors
Super Offset : 8 sectors
State : active
Device UUID : c792c6b2:78fd4e78:e4f008ea:826e25e8

Update Time : Sat Apr 6 13:17:10 2013
Checksum : 30386dbe - correct
Events : 103

Layout : left-symmetric
Chunk Size : 512K

Device Role : Active device 0
Array State : AAAA ('A' == active, '.' == missing)


/dev/sdg:
Magic : a92b4efc
Version : 1.2
Feature Map : 0x0
Array UUID : dc344271:82f55bd0:fcfd0e16:a2a60bc8
Name : TTVServer:TTV2 (local to host TTVServer)
Creation Time : Mon Jan 7 11:03:39 2013
Raid Level : raid5
Raid Devices : 4

Avail Dev Size : 5860531120 (2794.52 GiB 3000.59 GB)
Array Size : 17581590528 (8383.56 GiB 9001.77 GB)
Used Dev Size : 5860530176 (2794.52 GiB 3000.59 GB)
Data Offset : 2048 sectors
Super Offset : 8 sectors
State : active
Device UUID : c0426118:614cb315:15c9a0ee:2ad88e26

Update Time : Sat Apr 6 13:17:10 2013
Checksum : 7638ae70 - correct
Events : 103

Layout : left-symmetric
Chunk Size : 512K

Device Role : Active device 1
Array State : AAAA ('A' == active, '.' == missing)



/dev/sdi:
Magic : a92b4efc
Version : 1.2
Feature Map : 0x0
Array UUID : dc344271:82f55bd0:fcfd0e16:a2a60bc8
Name : TTVServer:TTV2 (local to host TTVServer)
Creation Time : Mon Jan 7 11:03:39 2013
Raid Level : raid5
Raid Devices : 4

Avail Dev Size : 5860531120 (2794.52 GiB 3000.59 GB)
Array Size : 17581590528 (8383.56 GiB 9001.77 GB)
Used Dev Size : 5860530176 (2794.52 GiB 3000.59 GB)
Data Offset : 2048 sectors
Super Offset : 8 sectors
State : active
Device UUID : 8a96d5fe:594418b6:c63dafd0:c459e498

Update Time : Sat Apr 6 13:17:10 2013
Checksum : 5175f080 - correct
Events : 103

Layout : left-symmetric
Chunk Size : 512K

Device Role : Active device 2
Array State : AAAA ('A' == active, '.' == missing)
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Raid control vs scsi for operating system

I was trying to get a server using a raid controller card up and running. I could not get the card configured right so i just installed the system strait onto a scsi drive. Questions? Is is nescessary to have the operating system on raid? Pros/Cons Is it really difficult to go back later... (1 Reply)
Discussion started by: macdonto
1 Replies

2. UNIX for Dummies Questions & Answers

Ultra60 and A1000....raid manager needed just to see it?

Hi guys, I was asked to setup an Ultra60 (Sol 8) with an StorEdge A1000. Does anyone know if a probe-scsi-all is suppose to detect it? Right now it doesn't, so maybe I answered my own question :rolleyes: We have an the same setup running already, but I wasn't around when that was setup. ... (3 Replies)
Discussion started by: Yinzer955i
3 Replies

3. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

4. Solaris

RAID controller needed for SVM?

hi this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network) i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
Discussion started by: Landser
4 Replies

5. UNIX for Advanced & Expert Users

need sample system o/p RHEL/Debian

Hi, Could somebody sent me sample output of below commands on 1) Debian linux and 2) RHEL3 and 3) any RHEL version less than 3, a) uname -a b) cat /etc/issue c) cat /etc/redhat-release or other equivalent file Thanks in advance - Krishna (0 Replies)
Discussion started by: krishnamurthig
0 Replies

6. Solaris

Contingency planning for System Failure

I have inhereted a Solaris 8 server which is running an important application in our production environment. The dilema is that the server has just one internal hard drive I believe it was installed using jump start, it does not even have a CD ROM drive and root is not mirrored (since there is... (2 Replies)
Discussion started by: Tirmazi
2 Replies

7. SCO

file system not getting mounted in read write mode after system power failure

After System power get failed File system is not getting mounted in read- write mode (1 Reply)
Discussion started by: gtkpmbpl
1 Replies

8. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

9. Debian

Best RAID settings for Debian Server? Help!! (1+0 or 5 or NAS)

I am installing a Debian Server on a: HP Proliant DL380 G4 Dual CPU's 3.20 ghz / 800 mhz / 1MB L2 5120 MB RAM 6 hard disks on HP Smart Array 6i controller (36.4 GB Ultra320 SCSI HD each) I will be using this server to capture VHS video, encode, compress, cut, edit, make DVD's, rip... (0 Replies)
Discussion started by: Marcus Aurelius
0 Replies

10. Shell Programming and Scripting

Help needed on restart-from-point-of-failure in Parallel Processing

Hi Gurus, Good morning... :) OS Info: Linux 2.6.32-431.17.1.el6.x86_64 #1 SMP Fri Apr 11 17:27:00 EDT 2014 x86_64 x86_64 x86_64 GNU/Linux I have a script which takes multiples parameters from a properties file one by one and run in background (to do parallel processing). As example: $ cat... (4 Replies)
Discussion started by: saps19
4 Replies
MD(4)							     Kernel Interfaces Manual							     MD(4)

NAME
md - Multiple Device driver aka Linux Software Raid SYNOPSIS
/dev/mdn /dev/md/n DESCRIPTION
The md driver provides virtual devices that are created from one or more independent underlying devices. This array of devices often con- tains redundancy, and hence the acronym RAID which stands for a Redundant Array of Independent Devices. md supports RAID levels 1 (mirroring) 4 (striped array with parity device) and 5 (striped array with distributed parity information). If a single underlying device fails while using one of these levels, the array will continue to function. md also supports a number of pseudo RAID (non-redundant) configurations including RAID0 (striped array), LINEAR (catenated array) and MUL- TIPATH (a set of different interfaces to the same device). MD SUPER BLOCK With the exception of Legacy Arrays described below, each device that is incorporated into an MD array has a super block written towards the end of the device. This superblock records information about the structure and state of the array so that the array can be reliably re-assembled after a shutdown. The superblock is 4K long and is written into a 64K aligned block that starts at least 64K and less than 128K from the end of the device (i.e. to get the address of the superblock round the size of the device down to a multiple of 64K and then subtract 64K). The available size of each device is the amount of space before the super block, so between 64K and 128K is lost when a device in incorporated into an MD array. The superblock contains, among other things: LEVEL The manner in which the devices are arranged into the array (linear, raid0, raid1, raid4, raid5, multipath). UUID a 128 bit Universally Unique Identifier that identifies the array that this device is part of. LEGACY ARRAYS Early versions of the md driver only supported Linear and Raid0 configurations and so did not use an MD superblock (as there is no state that needs to be recorded). While it is strongly recommended that all newly created arrays utilise a superblock to help ensure that they are assembled properly, the md driver still supports legacy linear and raid0 md arrays that do not have a superblock. LINEAR A linear array simply catenates the available space on each drive together to form one large virtual drive. One advantage of this arrangement over the more common RAID0 arrangement is that the array may be reconfigured at a later time with an extra drive and so the array is made bigger without disturbing the data that is on the array. However this cannot be done on a live array. RAID0 A RAID0 array (which has zero redundancy) is also known as a striped array. A RAID0 array is configured at creation with a Chunk Size which must be a power of two, and at least 4 kibibytes. The RAID0 driver assigns the first chunk of the array to the first device, the second chunk to the second device, and so on until all drives have been assigned one chunk. This collection of chunks forms a stripe. Further chunks are gathered into stripes in the same way which are assigned to the remaining space in the drives. If devices in the array are not all the same size, then once the smallest device has been exhausted, the RAID0 driver starts collecting chunks into smaller stripes that only span the drives which still have remaining space. RAID1 A RAID1 array is also known as a mirrored set (though mirrors tend to provide reflect images, which RAID1 does not) or a plex. Once initialised, each device in a RAID1 array contains exactly the same data. Changes are written to all devices in parallel. Data is read from any one device. The driver attempts to distribute read requests across all devices to maximise performance. All devices in a RAID1 array should be the same size. If they are not, then only the amount of space available on the smallest device is used. Any extra space on other devices is wasted. RAID4 A RAID4 array is like a RAID0 array with an extra device for storing parity. Unlike RAID0, RAID4 also requires that all stripes span all drives, so extra space on devices that are larger than the smallest is wasted. When any block in a RAID4 array is modified the parity block for that stripe (i.e. the block in the parity device at the same device offset as the stripe) is also modified so that the parity block always contains the "parity" for the whole stripe. i.e. its contents is equiva- lent to the result of performing an exclusive-or operation between all the data blocks in the stripe. This allows the array to continue to function if one device fails. The data that was on that device can be calculated as needed from the parity block and the other data blocks. RAID5 RAID5 is very similar to RAID4. The difference is that the parity blocks for each stripe, instead of being on a single device, are dis- tributed across all devices. This allows more parallelism when writing as two different block updates will quite possibly affect parity blocks on different devices so there is less contention. This also allows more parallelism when reading as read requests are distributed over all the devices in the array instead of all but one. MUTIPATH MULTIPATH is not really a RAID at all as there is only one real device in a MULTIPATH md array. However there are multiple access points (paths) to this device, and one of these paths might fail, so there are some similarities. A MULTIPATH array is composed of a number of logical different devices, often fibre channel interfaces, that all refer the the same real device. If one of these interfaces fails (e.g. due to cable problems), the multipath driver to attempt to redirect requests to another interface. UNCLEAN SHUTDOWN When changes are made to a RAID1, RAID4, or RAID5 array there is a possibility of inconsistency for short periods of time as each update requires are least two block to be written to different devices, and these writes probably wont happen at exactly the same time. Thus if a system with one of these arrays is shutdown in the middle of a write operation (e.g. due to power failure), the array may not be consis- tent. To handle this situation, the md driver marks an array as "dirty" before writing any data to it, and marks it as "clean" when the array is being disabled, e.g. at shutdown. If the md driver finds an array to be dirty at startup, it proceeds to correct any possibly inconsis- tency. For RAID1, this involves copying the contents of the first drive onto all other drives. For RAID4 or RAID5 this involves recalcu- lating the parity for each stripe and making sure that the parity block has the correct data. If a RAID4 or RAID5 array is degraded (missing one drive) when it is restarted after an unclean shutdown, it cannot recalculate parity, and so it is possible that data might be undetectably corrupted. The md driver currently does not alert the operator to this condition. It should probably fail to start an array in this condition without manual intervention. RECOVERY If the md driver detects any error on a device in a RAID1, RAID4, or RAID5 array, it immediately disables that device (marking it as faulty) and continues operation on the remaining devices. If there is a spare drive, the driver will start recreating on one of the spare drives the data what was on that failed drive, either by copying a working drive in a RAID1 configuration, or by doing calculations with the parity block on RAID4 and RAID5. While this recovery process is happening, the md driver will monitor accesses to the array and will slow down the rate of recovery if other activity is happening, so that normal access to the array will not be unduly affected. When no other activity is happening, the recovery process proceeds at full speed. The actual speed targets for the two different situations can be controlled by the speed_limit_min and speed_limit_max control files mentioned below. FILES
/proc/mdstat Contains information about the status of currently running array. /proc/sys/dev/raid/speed_limit_min A readable and writable file that reflects the current goal rebuild speed for times when non-rebuild activity is current on an array. The speed is in Kibibytes per second, and is a per-device rate, not a per-array rate (which means that an array with more disc will shuffle more data for a given speed). The default is 100. /proc/sys/dev/raid/speed_limit_max A readable and writable file that reflects the current goal rebuild speed for times when no non-rebuild activity is current on an array. The default is 100,000. SEE ALSO
mdadm(8), mkraid(8). MD(4)
All times are GMT -4. The time now is 08:33 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.