Sponsored Content
Operating Systems Solaris Can we configure link based IPMP in private connectivity in Oracle RAC Post 302771040 by Corona688 on Tuesday 19th of February 2013 11:32:30 AM
Old 02-19-2013
Quote:
Originally Posted by DGPickett
The N Ohm rating on the cable says that a light second long cable would draw current like a N ohm resistor for two seconds
I have been searching for a coherent explanation why telecom cable are rated in 'ohms' for two decades. Thank you!
 

3 More Discussions You Might Find Interesting

1. Solaris

Link based Active Active IPMP

Hi, I need to configure 4 ip address (same subnet and mask) in one ipmp group (two interfaces) in an active active formation (link based). Can some one provide the steps or a tutorial link. Thanks (2 Replies)
Discussion started by: Mack1982
2 Replies

2. Solaris

IPMP on Private interconnects

I have a Oracle dbase running in a Solaris 10 cluster and have two private interconnects that are being used for communication. Is there any way to connect these two interconnects together using IPMP for redundancy? I've made several attempts with no luck so far and was wondering if anyone had... (17 Replies)
Discussion started by: goose25
17 Replies

3. Solaris

Link Based IPMP on Shared IP Solaris Zone

Hi, This may have already been raised previously so sorry for the duplication. What I want to achieve is have a physical server using link based IPMP setup in the global zone (not problem doing that) and then create a zone set as Shared-IP so when the servers NIC has an issue the IP will... (0 Replies)
Discussion started by: giles.cardew
0 Replies
scconf_transp_adap_ce(1M)				  System Administration Commands				 scconf_transp_adap_ce(1M)

NAME
scconf_transp_adap_ce - configure the ce Sun Ethernet transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure ce adapters as cluster transport adapters. These adapters can be used with transport types dlpi. The ce adapter is VLAN capable. A ce adapter connects to a transport switch or to another ce adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ce(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ce(1M)