02-13-2013
Ok I'll give it a try. Thanks anyway.
One more question. We have 4 HDDs. Will HD 3+4 automatically be assigned to Domain 1 ?
10 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
I want to look into a folder to see if there are any folders within it. If there are, I need to check inside each folder to see if it contains a .pdf file
So
If /myserver/myfolder/
contains a folder AND that folder conatins a .pdf file
do X
Else
do Z
I may have multiple folders and... (4 Replies)
Discussion started by: crowman
4 Replies
2. Solaris
Pre: no gpasswd/adduser
there is just usermod can be used, also there is no -a option for usermod.
How should I add a user into a group? (4 Replies)
Discussion started by: a2156z
4 Replies
3. Windows & DOS: Issues & Discussions
Dear Expert,
i have linux box that is running in the windows domain, BUT did not being a member of the domain. as I am not the System Administrator so I have no control on the server in the network, such as modify dns entry , add the linux box in AD and domain record and so on that relevant.
... (2 Replies)
Discussion started by: regmaster
2 Replies
4. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
5. Shell Programming and Scripting
I have a source file like this,
L4058S462 34329094 F51010141TK1070000483L4058S462 34329094 0232384840 381892 182 5690
L4058S462 34329094 F51020141FIRST CLEARING, LLC A/C 3432-9094
L4058S462 34329094 F51030141JOHAN HOLMQVIST ... (1 Reply)
Discussion started by: saravanamr
1 Replies
6. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
7. Hardware
Does it Moving the dvd drive domain 0 to domain1 on M5000 sun server (1 Reply)
Discussion started by: rama3479
1 Replies
8. UNIX for Advanced & Expert Users
Hi,
This Sun M5000 currently has a single domain (0) created. Solaris 10 is installed on this domain with some local zones. Now we need to add a secondary hardware domain (1) to this M5000. My question: Can we keep the current OS settings on domain 0 when adding the secondary domain 1?
... (0 Replies)
Discussion started by: aixlover
0 Replies
9. Solaris
Hi,
This Sun M5000 currently has a single domain (0) created. Solaris 10 is installed on this domain with some local zones. Now we need to add a secondary hardware domain (1) to this M5000. My question: Can we keep the current OS settings on domain 0 when adding the secondary domain 1?
Thank... (5 Replies)
Discussion started by: aixlover
5 Replies
10. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
SBP(4) BSD Kernel Interfaces Manual SBP(4)
NAME
sbp -- Serial Bus Protocol 2 (SBP-2) Mass Storage Devices driver
SYNOPSIS
kldload firewire
kldload cam
kldload sbp
or
device sbp
device firewire
device scbus
device da
device cd
device pass
DESCRIPTION
The sbp driver provides support for SBP-2 devices that attach to the FireWire (IEEE 1394) port. It should work with SBP-2 devices which the
CAM layer supports, for example, HDDs, CDROM drives and DVD drives.
Some users familiar with umass(4) might wonder why the device is not detached at the CAM layer when the device is unplugged. It is detached
only if the device has not been plugged again during several bus resets. This is for preventing to detach an active file system even when
the device cannot be probed correctly for some reason after a bus reset or when the device is temporary disconnected because the user changes
the bus topology. If you want to force to detach the device, run ``fwcontrol -r'' several times or set hw.firewire.hold_count=0 by
sysctl(1).
Some (broken) HDDs do not work well with tagged queuing. If you have problems with such drives, try ``camcontrol [device id] tags -N 1'' to
disable tagged queuing.
SEE ALSO
cam(4), firewire(4), camcontrol(8), fwcontrol(8), kldload(8), sysctl(8)
AUTHORS
The sbp driver was written by Katsushi Kobayashi and Hidetoshi Shimokawa.
This manual page was written by Katsushi Kobayashi.
BSD
May 20, 2002 BSD