This is certainly not as elegant as I wanted it to be and as above proposals:
I was erroneously thinking the s///NUMBER flag would allow for ranges like 1-50, but it doesn't, does it? So the entire thing ended up clumsy...
Hello guys..
I have the following question.
lets have that i have the following variable:
$field=werfiurd383nd93bc93 c93 d93 d9e3 ddd
or
array=werfiurd383nd93bc93 c93 d93 d9e3 ddd
what i would like to do is to store the first 4 characters of gthe aboce variable in variable... (1 Reply)
Hello
I am currently having problems in mapulating a certain file which contains vaious data.
Belos is a sample content
Event=<3190>
Client IP=<151.111.11.143> DNS=<abc.sbc.com> TransCount=<139>
Client IP=<150.222.133.163> DNS=<xyz.yuu.com> TransCount=<3734>
Event=<3120>
Client... (11 Replies)
Hi everyone..
I am new here, hello.. I hope this doesn't come across to you folks as a stupid question, I'm somewhat new to scripting :)
I'm seeking some help in finding a way to manipulate data output for every two characters - example:
numbers.lst contains the following output:... (3 Replies)
i have a file in follwing format
0110
1020
1011
1032
1020
2005
2003
1050
i want the output in such a way that all non zero numbers will be converted into 1
like this
0110
1010
1011
1011
1010
1001
1001
1010 (3 Replies)
Hi all!
my first post here, so mods -- if this should ideally be in the scripts section, please move there. Thanks!
I have data in the following format:
key1:value1 key2:value2 key3:value3
A
B
C
D
key1:value4 key2:value5 key3:value6
A1
B1
key1: ...
and so on
I want an output... (2 Replies)
Hallo Team,
I need to manipulate existing data file. Have a look at current data and expected data:
Current Data:
27873517141
27873540000
27873515109
27873517140
27873540001
27873540000
27873501343
27873540000
27873517140
27873511292
27873645989
27873540000
27873540000... (7 Replies)
Dear Sir,
I have file input
RGR001|108.28|-2.86489|100-120|RANGGAR
RGR002|108.071|-2.69028|80-100|RANNGAR
RGR003|108.168|-2.97053|50-80|RANNGAR
RGR007|108.192722222|-2.766138889|0-50|RANGGARI want to create files by joining each rows with each rows below
Output as below
... (4 Replies)
Hello,
I have a huge set of data that needs to be reformatted.
Here is a simple example to explain the process.
I have number n=5 and a input with many numbers separated with comma:
... (11 Replies)
Discussion started by: liuzhencc
11 Replies
LEARN ABOUT DEBIAN
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.9.0-pre1 October 2010 IRSEND(1)