Sponsored Content
Operating Systems Solaris Netra 440 maintenance light on Post 302723461 by DukeNuke2 on Tuesday 30th of October 2012 08:03:57 AM
Old 10-30-2012
i would say that this is an ALOM bug in some way... please check the ALOM log and also check the FW level of the servers ALOM and update to latest level if possible.

hth,
DN2
 

7 More Discussions You Might Find Interesting

1. Solaris

440 MHz problems in UltraSparc 5 Computer

Hi all, I recently purchased a 440 MHz processor module for my Sun Ultrasparc 5 computer. I installed the module, updated the boot prom to the most recent version and when the machine starts up the initial white screen shows I have a 333 MHz processor installed ! I checked the details of the... (2 Replies)
Discussion started by: usparche
2 Replies

2. Solaris

Netra V440 & Netra 1290 keyswitch

Hello, I wrote a script which monitor the keyswitch state repeatedly each 10 minutes. I'm extracting the keyswitch status by using prtdiag. The script works fine for Netra v440 , but I found that prtdiag under Netra 1290 don't give keyswitch status. unlike Netra 440 server , I found that... (2 Replies)
Discussion started by: Alalush
2 Replies

3. Solaris

Hardware error in Netra 440 server

Dear All I am getting these error while I boot the Netra 440 server. Could anyone tell me what can be the problem Regards Copyright 2004 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Sun(tm) Advanced Lights Out Manager 1.5.4 (indcc01ma02) ... (6 Replies)
Discussion started by: amity
6 Replies

4. Solaris

netra 440 - alom connection appears dead?

Hi All, I'm trying to telnet to my alom port, as I need to drop the box & carry out some changes in single user. But the connection appears to be dead. I get this far: Connected to server1-co Escape character is '^]'. and the connection just appears to hang there. I can ssh to the box... (1 Reply)
Discussion started by: badoshi
1 Replies

5. Solaris

errors on Netra-440: "IPC Warning: ipc: tcp_protocol: bad magic number"

I was asked to look into a problem with a Sun Netra 440 in another department. On the server in question, the relevant 'uname -a' information is, "SunOS host1 5.9 Generic_118558-16 sun4u sparc SUNW,Netra-440". That information aside, while the other admin is logged into the ALOM, these errors are... (0 Replies)
Discussion started by: Borealis
0 Replies

6. Solaris

part number for netra 440 dvd w

Hi i am accessing the server remotly. i want to replace bad dvd writer. how do i know the part number of the dvd drive for raising a spare. thanks (3 Replies)
Discussion started by: sunnybee
3 Replies

7. What is on Your Mind?

A little light entertainment... ;oD

New O'Reilly books... URL: New O'Reilly books - Album on Imgur I'll bet many of you have come across a few of these... ;oD (0 Replies)
Discussion started by: wisecracker
0 Replies
IPRUPDATE(8)						      System Manager's Manual						      IPRUPDATE(8)

NAME
iprupdate - IBM Power RAID adapter/device microcode update utility SYNOPSIS
iprupdate iprupdate --debug --check_only --daemon --use-polling --use-uevents DESCRIPTION
iprupdate is used to update the microcode on IBM storage adapters and the disk units attached to them to a minimum supported level. It can be run at any time while the ipr device driver is loaded. The utility will check the microcode revision level of each storage adapter/disk unit on the system and compare it to the microcode revision level that is installed in /etc/microcode, /usr/lib/microcode, and /lib/firmware. If the microcode level on the adapter/device is below the minimum supported level and the level of the latest image is newer, the microcode will be updated to the latest level available. It is desired that this be called in the boot process. OPTIONS
--version Print the version number of iprupdate --debug Enable additional error logging. Enabling this will result in additional errors logging to /var/log/messages. --check_only Check if any adapters or disk units are below their minimum supported level. --daemon Run as a daemon to handle adapters and devices being hotplugged. --use-polling Do not use netlink/uevent notification, but rather poll for adapter and device configuration changes. --use-uevents Use netlink/uevent notification rather than polling for adapter and device configuration changes. If not specified, polling will be used until the first uevent notification appears, then netlink will be used. AUTHOR
Brian King (brking@us.ibm.com) February 2005 IPRUPDATE(8)