08-20-2012
There is no such pack installed.
This means that can not restore this recovery DVD on a PC that has SATA hard drive.is it true?
(When i trying to restore on the PC has SATA ,it try to examine the size of memory and when it passes, in the command line"Loading floppy image to memory" hults.what do you think?)
Thanks man
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hi All,
Please check the below ftp related job, which is deleting the files from remote host. Problem is it is not capturing the ftp failure error, and the exit status is still '0' eventhough the deletable files are not present in remote location OR ftp credential are incorrect.
... (5 Replies)
Discussion started by: ganapati
5 Replies
2. Solaris
Hi Guys,
Anybody come across this error when formating a harddisk. "Reserved Failed"
Supected hardisk failure, is my assumption correct.
Thanks (5 Replies)
Discussion started by: bigmoon
5 Replies
3. HP-UX
Hi,
I have installed automake in one of HP-UX boxes using swinstall command. But when i issue automake it gives the following error message.
Can't locate loadable object for module IO in @INC (@INC contains: /usr/local/share/automake-1.10 /usr/local/lib/perl5/5.8.8/PA-RISC2.0... (1 Reply)
Discussion started by: chrisanto_2000
1 Replies
4. UNIX for Advanced & Expert Users
# netstat -a > /test/a
getnameinfo failed
getnameinfo failed
getnameinfo failed
getnameinfo failed
getnameinfo failed
command is working fine (as i get output in file /test/a)
# dig -x 10.xxx.xxx.xxx
; <<>> DiG 9.3.3rc2 <<>> -x 10.203.xxx.xxx
;; global... (0 Replies)
Discussion started by: crackthehit007
0 Replies
5. Solaris
Hi,
i got the following error when i tried to access the cygwin x server from a windows XP PC.
"xdmcp fatal error session failed session 23 failed for display"
Alternatively, when i tried to access the same Cygwin X Server from another windows XP PC which is on a different LAN... (3 Replies)
Discussion started by: HarishKumarM
3 Replies
6. Solaris
Hi
Could any one explain the meaning & purpose of below mention parameters in layman term. Suppose if we set below paramet what will happen.
error-reset-recovery=boot
error-reset-recovery=sync (3 Replies)
Discussion started by: sb200
3 Replies
7. Solaris
I have two servers with a fresh install of Solaris 11, and having problems when doing rpcinfo between them. There is no firewall involved, so everything should theoretically be getting through. Does anyone have any ideas? I did a lot of Google searches, and haven't found a working solution yet.
... (2 Replies)
Discussion started by: christr
2 Replies
8. Solaris
Hi
I tried to boot as single-user mode on my sunfire t1000 to change my root password since the guy has left the company without give us the root password.
anyhow since this machine not have attached with cd/dvd/usb so the only think that to do it through Jumpstart
now i tried to... (8 Replies)
Discussion started by: jmishal
8 Replies
9. UNIX for Advanced & Expert Users
I have created a windows server 2008 r2 Active Directory Server where I will create users. These users will be AD owners of data created on SUSE-OES server.
I am facing issue while while creating my suse-oes server account to ade server.
When I try to join my linux box to this windows AD... (0 Replies)
Discussion started by: rupeshkp728
0 Replies
10. HP-UX
I have a B.11.31 U ia64 system where I swremove the disk driver "SerialSCSI-00 B.11.31.1303 PCI-X/PCI-E SerialSCSI" (by mistake). afterwards the system won;t boot because of the missing disk drivers. I'm trying to recover my kernel by using the image HP-ux_11_31_disc_1.iso
Run an Expert... (1 Reply)
Discussion started by: black_fender
1 Replies
LEARN ABOUT NETBSD
arcmsr
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)
NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)
HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD
March 3, 2008 BSD