How can i modify (expand) the swap memory (Sco Enterprise 5.0.5) using the swap command...? The excisting swap is 512 and i want to increase it to 1024...?
Thanx in advance (2 Replies)
Hi,
I have a conf.file with the following values:
ef=78
b=40
ca=40
c=45/dev2
when I modify one of the line with the below awk script,it's modifying BUT it's placing the modified line in the last line :
input:- Configure b 45/dev4
output:-
ef=78
ca=40
... (2 Replies)
I want the below script to omit every chunk of data that contains a specific hostname.
here's the scenario. i have a configuration file that contains the configuration of several hosts. a sample of this configuration file is this:
define host {
address ... (12 Replies)
so i have this data in a file:
jime=1860,yime=1.23243,lime=
jime=1859,yime=1.23018,lime=
jime=1825,yime=1.15371,lime=
jime=1849,yime=1.20769,lime=
jime=1841,yime=1.1897,lime=
jime=1849,yime=1.20769,lime=
i use this code to calculate the percentage difference of the number in column 2... (9 Replies)
Hello,
I am using awk command to print some output, but there are some characters that I would like to remove from the output
awk '{print $5$6}'
the output I get is
column5/:column6
I am looking forward to remove the : and to get the output
column5/column6
Sorry if this question is... (4 Replies)
Hi,
I have to modify the 2nd and 3rd octet of the IP address through awk/sed.
For Example:
Given IP is : 10.205.22.254, it should be modified as 10.105.100.254 through awk/sed.
Kindly help me on this and let me know if you have any questions.
Thanks in advances. (2 Replies)
i have a php file that has this:
php.code
#!/usr/bin/php
<?php
phpinfo();
hlight_file(__FILE__);
?>
I want my awk code grab whatever is inbetween and including the "<?php" and "?>".
Then, it should scan all the entries between these two points. And if the entries between these... (10 Replies)
I'm usia Raspbian, a Debian subset, and wondering what work would be involved in altering the cp command.
cp at present needs a full path and file name for source and at least full filename for destination. How can I change this so the second parameter isn't needed? So if the destination... (6 Replies)
Discussion started by: MuntyScrunt
6 Replies
LEARN ABOUT CENTOS
sane-sp15c
sane-sp15c(5) SANE Scanner Access Now Easy sane-sp15c(5)NAME
sane-sp15c - SANE backend for Fujitsu ScanPartner 15C flatbed scanner
DESCRIPTION
The sane-sp15c library implements a SANE (Scanner Access Now Easy) backend which provides access to the Fujitsu flatbed scanners. At
present, the following scanner is known to work with these backend:
Vendor: Model: Rev:
-------- ---------------- -----
FCPA ScanPartner 15C 1.01
The ScanPartner 15C driver supports lineart (1-bit), halftone (1-bit), grayscale (4-bit and 8-bit), and color (3 x 8-bit) scanning.
Other scanners in these families may work. The ScanPartner 15C seems to be a repackaging of the ScanPartner 600C. People are encouraged
to try these driver with the other scanners and to contact the author with test results.
CONFIGURATION
A modest effort has been made to expose the standard options to the API. This allows frontends such as xscanimage to set scanning region,
resolution, bit-depth (and color), and enable the automatic document feeder.
SEE ALSO sane(7), sane-scsi(5), sane-fujitsu(5)
Fujitsu ScanPartner 15C OEM Manual, Doc. No. 250-0081-0
Fujitsu M3096G OEM Manual, part number 50FH5028E-05
Fujitsu M3096GX/M3093GX/M3093DG OEM Manual, part number C150-E015...03
AUTHOR
Randolph Bentson <bentson@holmsjoen.com>, with credit to the unnamed author of the coolscan driver
LIMITATIONS
Testing limited to a Linux 2.2.5 kernel
Can't quite get the scan page/minute performance in ADF modes. This may be due to limited system buffer size.
BUGS
I'm sure there are plenty, and not too well hidden, but I haven't seen them yet.
Both scanners claim to have separate control of resolution in X and Y directions. I confess I haven't tested this yet. I have found that
xsane doesn't even display this capability.
Threshold settings on the SP15C don't seem to affect the results of lineart mode scans.
It might be possible to merge these two drivers without much effort since the SP15C driver was derived from the M3096G driver. They were
split so as to keep the second driver development from breaking the working first driver. Watch this space for changes.
14 Jul 2008 sane-sp15c(5)