Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302645909 by methyl on Thursday 24th of May 2012 09:16:04 AM
Old 05-24-2012
According to "when good disks go bad" for an Iantium boot disk, the partitioning comes first.

Sorry to mislead you. Myself and vbe don't have 11.23 on Iantium and the new procedure is different from every earlier version.
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
voldiskadd(8)						      System Manager's Manual						     voldiskadd(8)

NAME
voldiskadd - Adds one or more disks for use with the Logical Storage Manager SYNOPSIS
/usr/sbin/voldiskadd disk-address-list DESCRIPTION
The voldiskadd utility sets up new disks that are added to the system after the initial system installation and configures the disks for use by the Logical Storage Manager. A valid disk label must exist on the disk before using the voldiskadd utility. One or more disks may be specified using a disk-address-list. Disk addresses in the list have the form dskn (for the entire disk) or dsknp (for a specific partition). When specifying multiple disks, use a space between entries. Disk address names relate directly to device names in the /dev/disk directory. For example, here are some valid voldiskadd disk-address-list specifications: # voldiskadd dsk1 # voldiskadd dsk2 dsk3a The file, /etc/vol/disks.exclude, may be used to exclude disks from use by voldiskadd. Each line of the file specifies the name of a disk to exclude (for example, dsk5). The voldiskadd utility prompts the user for a disk group name and disk media name for the disks. If a new disk group name is specified, that disk group is created for the new disks. If no disk group name is specified, the disks are left as unassigned replacement disks for future use. If an existing disk group name is specified, the user is prompted for whether the disks should be designated as spares for the disk group. If a disk is found to already contain non-Logical Storage Manager partitioning, the user is asked whether the disk should be encapsulated. Encapsulation turns each partition of the disk into a volume. A disk should be encapsulated if it contains file systems or data that should not be overwritten. If encapsulation is not desired for a disk, the disk can be initialized as a new disk for use by the Logical Storage Manager. For new disks, all space on the disk becomes free space in the disk's disk group. Context-sensitive help is available at every prompt by typing ?. Also, a list option can be used to get information on available target disks for an operation. The voldiskadd utility supports the following general classes of actions: Initializing a disk with reserved regions and partitions. Disk initialization is performed by calling voldisksetup command. Adding a disk to an existing disk group. This operation can be performed independently of the initialization of the disk drive to add a disk's storage space to a disk group's free space pool. The volassist command may subsequently allocate from that free space. The disk can also be added as a hot spare device. Creating new disk groups in which to import new disks. If no disk group exists for importing disks, the option of creating the disk group is offered. Encapsulating disks that have exist- ing contents. This is the default action for disks that do not have a valid, existing Logical Storage Manager private region, but that do have a disk label. Encapsulation is performed by calling volencap. Reconnecting a drive that was temporarily inaccessible. This situation is detected automatically, by noting that the specified drive has a disk ID that matches a disk media record with no currently associated physical disk. After reconnection, any stale plexes referring the disk are reattached, and any stopped volumes referring the disk are restarted. This reattach action is performed by calling the volrecover script. ERRORS
You may receive the following messages when using the voldiskadd command: Initialization of disk device special-device failed. Error: special-device or an overlapping partition is open. This message indicates that the partition you specified or an overlapping partition on the disk is actively in use. The partition could be a mounted UFS or AdvFS filesystem, initialized as an LSM disk or used as a swap device. special-device is marked in use for fstype in the disklabel. If you continue with the operation you can possibly destroy existing data. Would you like to continue?? [y,n,q,?] (default: n) This message indicates that the fstype of a partition or an overlapping partition is set in the disk label. The voldiskadd command prints this message to warn that a disk partition may have valid data which could be destroyed. If you are sure that the disk partition does not have valid data and that the partition can be added to LSM, you can ignore the warning message by entering y at the prompt. The voldiskadd command will proceed to initialize the disk partition and add it to LSM. FILES
A list of disks to exclude from use by voldiskadd. SEE ALSO
disklabel(8), volassist(8), voldisk(8), voldiskadm(8), voldisksetup(8), voldg(8), volintro(8) voldiskadd(8)
All times are GMT -4. The time now is 01:20 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy