Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302645555 by methyl on Wednesday 23rd of May 2012 05:06:05 PM
Old 05-23-2012
@vbe
methyl is listening, but busy with a work job and on UK time.
Would like to know the exact hardware specification for this system (HP don't sell "300GB hot-swappable disks") and the expected mirror configuration. Not prepared to guess.
Let's eliminate the obvious. Is /var/adm/syslog.log full of SCSI LBOLT errors and other disc/controller disaster signs? Has someone visited the server to make sure that the power supply is intact and that the SCSI cable has not become displaced? What lights are lit on the disc drives (both of them)? Red, Green, flashing Green, none?

At the end of this, please consider fitting a third disc drive with view to triple mirroring.
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
TAPEINFO(1)						      General Commands Manual						       TAPEINFO(1)

NAME
tapeinfo - report SCSI tape device info SYNOPSIS
tapeinfo -f <scsi-generic-device> DESCRIPTION
The tapeinfo command reads various information from SCSI tape drives that is not generally available via most vendors' tape drivers. It issues raw commands directly to the tape drive, using either the operating system's SCSI generic device ( e.g. /dev/sg0 on Linux, /dev/pass0 on FreeBSD) or the raw SCSI I/O ioctl on a tape device on some operating systems. One good time to use 'tapeinfo' is immediately after a tape i/o operation has failed. On tape drives that support HP's 'tapealert' API, 'tapeinfo' will report a more exact description of what went wrong. Do be aware that 'tapeinfo' is not a substitute for your operating system's own 'mt' or similar tape driver control program. It is intended to supplement, not replace, programs like 'mt' that access your operating system's tape driver in order to report or set information. OPTIONS
The first argument, given following -f , is the SCSI generic device corresponding to your tape drive. Consult your operating system's doc- umentation for more information (for example, under Linux these are generally start at /dev/sg0 under FreeBSD these start at /dev/pass0). Under FreeBSD, 'camcontrol devlist' will tell you what SCSI devices you have, along with which 'pass' device controls them. Under Linux, "cat /proc/scsi/scsi" will tell you what SCSI devices you have. BUGS AND LIMITATIONS
This program has only been tested on Linux with a limited number of tape drives (HP DDS4, Seagate AIT). AVAILABILITY
tapeinfo is currently being maintained by Eric Lee Green <eric@badtux.org> formerly of Enhanced Software Technologies Inc. The 'mtx' home page is http://mtx.sourceforge.net and the actual code is currently available there and via CVS from http://sourceforge.net/projects/mtx/ . SEE ALSO
mt(1),mtx(1),scsitape(1) TAPEINFO1.0 TAPEINFO(1)
All times are GMT -4. The time now is 05:57 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy