Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302645469 by vbe on Wednesday 23rd of May 2012 01:04:48 PM
Old 05-23-2012
My two cents:
You have an Integrity box, I only know PA-RISC... (worked with since 1993...), only I had to change a couple of times bad disks, reading the updated When Good Disks Go Bad: Dealing with Disk Failures Under LVM I would stick from your point 10 to what is to do on page 51 step 5 and 6 and do only that!
I will be away for 5 days but other here surely will take over (methyl?)


point4:
You must
Code:
 scsimgr replace_wwid –D /dev/rdisk/disk13

because you have not rebooted OK?
so 5: you run ioscan -m lun

point 6:
Code:
insf -eC disk

I am not sure that after, you need to initialize (using the above options...)...
So check before with
Code:
efi_ls -d /dev/rdsk/c3t0d0s1


Last edited by vbe; 05-23-2012 at 02:22 PM.. Reason: URL...
This User Gave Thanks to vbe For This Post:
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
oidentd_masq.conf(5)						File Formats Manual					      oidentd_masq.conf(5)

NAME
oidentd_masq.conf - oidentd IP masquerading/NAT configuration file. DESCRIPTION
If you are using IP masquerading or NAT, oidentd can optionally return a username for connections from other machines. Support for this is specified by calling oidentd with the -m (or --masq) flag and by creating an /etc/oidentd_masq.conf file. oidentd can also forward requests for an IP masqueraded connection to the machine from which connection originates by way of the -f option. This will only work if the host to which the connection is forwarded is running oidentd with the -P (proxy) flag, or if the host's ident daemon will return a valid reply regardless of the input supplied by and the address of the host requesting the info (some ident daemons for windows do this, maybe others). FORMAT
<IP Address|Hostname>[/<Mask>] <Ident Response> <System Type> The first field contains the IP address or the hostname of a machine that IP masquerades through the machine on which oidentd runs. The mask parameter can be either a network mask or a mask in CIDR notation. A mask of 24 is equivalent to 255.255.255.0, a mask of 16 is equivalent to 255.255.0.0, etc. The second field specifies the reply that oidentd will return for lookups to the host matching the IP address specified in the first param- eter. The third field specifies the operating system the machine matching the first parameter is running. EXAMPLES
<Host>[/<Mask>] <Ident Response> <System Type> 192.168.1.1 someone UNIX 192.168.1.2 noone WINDOWS 192.168.1.1/32 user1 UNIX 192.168.1.0/24 user3 UNIX 192.168.0.0/16 user4 UNIX somehost user5 UNIX 192.168.1.0/255.255.255.0 user6 UNIX AUTHOR
Ryan McCabe <ryan@numb.org> http://dev.ojnk.net SEE ALSO
oidentd(8) oidentd.conf(5) version 2.0.8 13 Jul 2003 oidentd_masq.conf(5)
All times are GMT -4. The time now is 12:46 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy