Old 05-19-2012
That's a memory module (DIMM) :

SYS = system
MB = main (or mother) board
CMP1 = CPU Module #1
BR1 = Branch #1
CH1 = Channel #1
D0 = DIMM #0

Last edited by jlliagre; 05-19-2012 at 09:36 AM..
 

10 More Discussions You Might Find Interesting

1. Solaris

equivalent prtdiag and prtconf command

I have a very old sunOS 4.xx server on a SPARCstation 5. What is the command , if any, that is similar to prtdiag and prtconf? Thanks (4 Replies)
Discussion started by: antalexi
4 Replies

2. UNIX for Dummies Questions & Answers

Question on prtdiag output ...

Hello all , This is the output of my prtdiag command ...The speed of each of the CPUs is listed below (1281 MHz ) ..That's fine ..I'm confused about the (System clock frequency: 183 MHZ ) ..What is the difference between System Clock freq and CPU freq ...THanks.. System Configuration: Sun... (5 Replies)
Discussion started by: luft
5 Replies

3. Solaris

Prtdiag is Not working in Solaris 8 Ver

Hello Guys, :confused: I have tried Up to my Levels pls help me if u know any solution Pls look out the following O/P, Log Messages ================================================= SUN> pwd /usr/platform/SUNW,Sun-Fire-V240/sbin SUN> SUN> SUN> prtdiag -v bash: prtdiag: command not... (7 Replies)
Discussion started by: sure.solaris
7 Replies

4. Solaris

prtdiag and memory banks

hi, we have an e6900 and my sys admin says that the number of processors and memory were reduced to 4 and 8GB. However, a prtdiag |grep Memory returns 16GB of memory. So what is my system's memory? psrinfo returns 4 online and 4 offline CPUs. Thanks. Kumar (1 Reply)
Discussion started by: kumar27
1 Replies

5. Solaris

prtdiag - Segmentation Fault

Hi, Recently installed a Firmware patch on T5120 (solaris 10,138888-03). The patch installation was Success and system came up fine as well. My apps are running fine too. Problem is prtdiag does not work as it used to earlier. the output is very different from other t5120s I have and... (1 Reply)
Discussion started by: upengan78
1 Replies

6. Solaris

SF T2000 prtdiag problem

Hi, a couple of T2000 servers did not show the component status and the output was too short. There was a patch that needed to be installed. I also updated to the latest recommended patch cluster and OBP patch. After reboot/restart of picl, it worked ok for a couple of weeks. Then suddenly it went... (12 Replies)
Discussion started by: incredible
12 Replies

7. UNIX for Advanced & Expert Users

prtdiag -v show no output

Dear All....Help required prtdiag -v command shows no output on my V440 server. Following is the details: root@sdp16b>prtdiag -v root@sdp16b> root@sdp16b>uname -a SunOS sdp16b 5.9 Generic_122300-31 sun4u sparc SUNW,Sun-Fire-V440 root@sdp16b>echo $path /usr/sbin /usr/bin /usr/sbin... (6 Replies)
Discussion started by: Junaid
6 Replies

8. UNIX for Dummies Questions & Answers

Interpreting prtdiag output - 2 or 4 CPUs?

I am having trouble figuring this one out.....Is this a 2CPU or a 4CPU v490 with 16GB? I think it is a 2CPU system, looking for confirmation. $ prtdiag System Configuration: Sun Microsystems sun4u Sun Fire V490 System clock frequency: 150 MHz Memory size: 16384 Megabytes ... (1 Reply)
Discussion started by: config_boy
1 Replies

9. Solaris

Understanding memory config with prtdiag -v

Hi. I have 2 SunFire V490 servers running Solaris 10. We may have to upgrade with more memory on one of them to make it compatible with the other. Here's the one with 12GB of RAM: Memory size: 12288 Megabytes ========================= CPUs =============================================== ... (1 Reply)
Discussion started by: th1amigo
1 Replies

10. Solaris

prtdiag

Hi everyone, Please can you tell me what kind of memro we are talking about when we run : prtdiag -v Memory size: 98016 Megabytes Thank you (7 Replies)
Discussion started by: adilyos
7 Replies
CosNotifyChannelAdmin_EventChannel(3erl)		     Erlang Module Definition			  CosNotifyChannelAdmin_EventChannel(3erl)

NAME
CosNotifyChannelAdmin_EventChannel - This module implements the OMG CosNotifyChannelAdmin::EventChannel interface. DESCRIPTION
To get access to the record definitions for the structures use: -include_lib("cosNotification/include/*.hrl"). This module also exports the functions described in: * CosNotification_QoSAdmin * CosNotification_AdminPropertiesAdmin EXPORTS
_get_MyFactory(Channel) -> ChannelFactory Types Channel = #objref ChannelFactory = #objref This readonly attribute maintains the reference of the event channel factory that created the target channel. _get_default_consumer_admin(Channel) -> ConsumerAdmin Types Channel = #objref ConsumerAdmin = #objref This is a readonly attribute which maintains a reference to a default ConsumerAdmin object associated with the target object. _get_default_supplier_admin(Channel) -> SupplierAdmin Types Channel = #objref SupplierAdmin = #objref This is a readonly attribute which maintains a reference to a default SupplierAdmin object associated with the target object. _get_default_filter_factory(Channel) -> FilterFactory Types Channel = #objref FilterFactory = #objref The default FilterFactory associated with the target channel is maintained by this readonly attribute. new_for_consumers(Channel, OpType) -> Return Types Channel = #objref OpType = 'AND_OP' | 'OR_OP' Return = {ConsumerAdmin, AdminID} ConsumerAdmin = #objref AdminID = long() This operation creates a new instance of a ConsumerAdmin and supplies an Id which may be used when invoking other operations exported by this module. The returned object will inherit the Quality of Service properties of the target channel. for_consumers(Channel) -> ConsumerAdmin Types Channel = #objref ConsumerAdmin = #objref A new new instance of a ConsumerAdmin object is created but no Id is returned. The returned object's operation type, i.e., 'AND_OP' or 'OR_OP' , will be set to the value of the configuration parameter filterOp . The target object's Quality of Service properties will be inherited by the returned ConsumerAdmin . new_for_suppliers(Channel, OpType) -> Return Types Channel = #objref OpType = 'AND_OP' | 'OR_OP' Return = {SupplierAdmin, AdminID} SupplierAdmin = #objref AdminID = long() Enables us to create a new instance of a SupplierAdmin . An Id, which may be used when invoking other operations exported by this module, is also returned. The current Quality of Service settings associated with the target object will be inherited by the Suppli- erAdmin . for_suppliers(Channel) -> SupplierAdmin Types Channel = #objref SupplierAdmin = #objref To create a new SupplierAdmin with the target object's current Quality of Service settings we can use this function. The returned object's operation type ( 'AND_OP' or 'OR_OP' ) will be determined by the configuration variable filterOp . get_consumeradmin(Channel, AdminID) -> ConsumerAdmin Types Channel = #objref AdminID = long() ConsumerAdmin = #objref | {'EXCEPTION', #'CosNotifyChannelAdmin_AdminNotFound'{}} If the given Id is associated with a ConsumerAdmin the object reference is returned. If such association never existed or the Con- sumerAdmin have terminated an exception is raised. get_supplieradmin(Channel, AdminID) -> SupplierAdmin Types Channel = #objref AdminID = long() SupplierAdmin = #objref | {'EXCEPTION', #'CosNotifyChannelAdmin_AdminNotFound'{}} Equal to the operation get_consumeradmin/2 but a reference to a SupplierAdmin is returned. get_all_consumeradmins(Channel) -> Reply Types Channel = #objref Reply = [AdminID] AdminID = long() To get access to all ConsumerAdmin Id's created by the target object, and still alive, this operation could be invoked. get_all_supplieradmins(Channel) -> Reply Types Channel = #objref Reply = [AdminID] AdminID = long() Equal to the operation get_all_consumeradmins/1 but returns a list of all SupplierAdmin object ID's. destroy(Channel) -> ok Types Channel = #objref The destroy operation will terminate the target channel and all associated Admin objects. Ericsson AB cosNotification 1.1.16 CosNotifyChannelAdmin_EventChannel(3erl)
All times are GMT -4. The time now is 02:32 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy