Sponsored Content
Operating Systems Solaris Connect from Dell Laptop to SunBlade 100 Post 302641129 by tomicmanka on Tuesday 15th of May 2012 04:29:21 PM
Old 05-15-2012
1. IP address assignment -> Done
2. Can you ping the blade from the laptop -> No , Request Timed out error
3. Is the telnet service running (on port 90?) -> yes, it was 23, I changed to 90 in /etc/services

---------- Post updated at 09:29 PM ---------- Previous update was at 09:25 PM ----------

The question I have is, do I need a router or is a RJ45 [network cable] cable connection between laptop and the SunBlade be enough for a telnet connection ?
 

10 More Discussions You Might Find Interesting

1. Solaris

NIC cards for sunblade 100

I need to add a PCI NIC to a sunblade 100 running solaris 8. Im new to this and was hoping someone could give me some card names and models which will work for this system and has a driver for this sparc system. thanks (3 Replies)
Discussion started by: meyersp
3 Replies

2. Solaris

regd.sunblade 100

hii alll i have a problem with my sunblade100. when i switch on, no display comes but if i ping from a remote machine its pinging,but iam not able to telent to that sun server,what can be the problem,how can i sort ot this issue 2 thing in usb iam not able to use STOP N (to clear the... (3 Replies)
Discussion started by: solaris8in
3 Replies

3. Debian

How to install Debian on a SUNBLADE 100?

I have tried to install the Debian distribution for SPARC processor, but is a pian in the neck trying to boot from cdrom or floppy. Please can somebody to help me to know the easiest way to boot and install Debian on a SUNBLADE 100 system? or wich is the best way to installed on this system, I... (2 Replies)
Discussion started by: GEIER
2 Replies

4. UNIX for Dummies Questions & Answers

How to connect laptop to Unix system via Parallel port

Hi, I have been using a computer to keep track of inventory for my business. I am pretty sure it runs on Unix. In the back of the computer there is some sort of PCI card that has about 8 RJ-11 ports on it. I use that card to connect the Unix system to my 3 VT-220 terminals. I use a simple 6... (1 Reply)
Discussion started by: john202
1 Replies

5. Solaris

Adding memory to a SunBlade 100

Question, when adding memory to a SunBlade 100, are you required to add it in matched pairs? My current box has 2 x 256mb sticks of PC-133 ram. I tried adding 1 512mb sticks and the system failed to come up. I saw at Sunsolve that you can mix and match different sized memory. (5 Replies)
Discussion started by: stocksj
5 Replies

6. Solaris

Help! Trying to install Solaris 10 on a Sunblade 100

I recently bought a sunblade 100 for $150 from a guy that posted it on craigslist. I'm trying to learn Solaris 10. Prior to giving me the system he had Ubuntu installed. He removed it for before giving it to me. I basically have a hard disk that has nothing installed in it. I tried installing... (6 Replies)
Discussion started by: haloy
6 Replies

7. Solaris

PC133 for sunblade 100

Greetings, I was in the mood of upgrading my sunblade100 in my bedroom, since I recuperated some RAM from intel servers, and found myself with what seems to not work (I was hoping to pass from 256Mb to 2GB... and then upgrading to solaris 10...) after this failure I tried with just one 512 MB,... (2 Replies)
Discussion started by: vbe
2 Replies

8. Ubuntu

Connect 2 laptops with RJ45 cable (Ubuntu 10.10 laptop with Windows 7 laptop)

Hi to all, I have the problem that a laptops with windows XP cannot startup even in safe mode nor using last good known configuration. I have a Ubuntu 10.10 Live CD and booting from it I can read the Hard Drive. I need to do a backup the Hard Drive from XP laptop and I want to connect this... (5 Replies)
Discussion started by: cgkmal
5 Replies

9. Hardware

How to connect a 4TB G-Raid hard drive to a laptop?

I am having trouble connecting my 4TB G-Raid Hard drive to my Compaq Hp laptop can anyone tell me how or what I need in order to connect the 4T and getting it working. (10 Replies)
Discussion started by: Jake Wolf
10 Replies

10. Hardware

Connect SATA Laptop HardDrive to Desktop SATA Slots

Hello everybody, I need to connect a laptop 2.5 SATA hard drive to a Desktop board (which uses 3.5' SATA hard drives). I've tried the connectors and they fit excellent in the 2.5 SATA connectors. The problem is that the laptop hard drive uses 5v and the PC's power source sends 12v. So, my... (4 Replies)
Discussion started by: Zykl0n-B
4 Replies
powerman-devices(7)						     powerman						       powerman-devices(7)

NAME
powerman-devices - Powerman Device Configuration Notes DESCRIPTION
Following are notes on configuring various remote power controllers and related equipment supported by PowerMan. CYCLADES TS-1000 A cyclades TS-1000 configured so that PowerMan can connect to serial-port-based remote power control devices using telnet is set up as fol- lows: Attach console cable between laptop running minicom and console port at 9600,8n1 and authenticate with default account: root/tslinux. Edit the following files (assumes no off-subnet routing or name service required): /etc/portslave/portslave.conf conf.eth_ip 192.168.54.151 conf.eth_mask 255.255.255.0 conf.dhcp_client 0 # all.speed 9600 all.datasize 8 all.stopbits 1 all.parity none all.flow none all.dcd 0 all.DTR_reset 1 all.protocol socket_server all.authtype none #all.ipno all.socket_port 7001+ # s1.tty ttyS1 s2.tty ttyS2 s3.tty ttyS3 s4.tty ttyS4 s5.tty ttyS5 s6.tty ttyS6 s7.tty ttyS7 s8.tty ttyS8 s9.tty ttyS9 s10.tty ttyS10 s11.tty ttyS11 s12.tty ttyS12 s13.tty ttyS13 s14.tty ttyS14 s15.tty ttyS15 s16.tty ttyS16 /etc/hostname cyclades-ts-test /etc/hosts 127.0.0.1 localhost 192.168.54.151 cycaldes-ts-test Next, run signal_ras hup and saveconf and finally, power cycle the unit. It should be possible to configure PowerMan to connect to host- name:7001 for port 1, hostname:7002 for port 2, etc.. BAYTECH RPC-3 (non-NC models) (network port 23) Attach console cable between laptop running minicom and console port at 9600,8n1. Main menu should display. From main menu, select 3)...Configuration, then set IP parameters. From Configuration menu, select 5)...Access, then disable command confirmation, set admin password to baytech, and enable prompt for pass- word. Exit Access menu by typing return. From Configuration menu, select 6)...Outlets. Ensure that 1)...Outlet Status display is disabled, and 2)...Command Confirmation is dis- abled. Exit back to main menu by typing return twice, then answer Y to the Accept changes? prompt. BAYTECH RPC-28-NC (serial 9600,8n1) Attach console cable between laptop running minicom and console port at 9600,8n1. Type return to get RPC-28> prompt. Type Help for a list of commands. Select config. Select 3)...Enable/Disable Confirmation and disable confirmation. Select 4)...Enable/Disable Status Menu and disable sta- tus menu LNXI ICEBOX V2 (network port 1010) Attach console cable between laptop running minicom and console port at 9600,8n1. Enter default password of icebox. net ip 192.168.54.153 Sets IP address. net mask 255.255.255.0 Sets network mask net gw 192.168.54.254 Set default gateway. Note: this may need to be set to an address in the same subnet as the ice box regardless of whether it is to be used or not. reboot Reboots the icebox. LNXI ICEBOX V3 (network port 1010) Attach console cable between laptop running minicom and console port at 9600,8n1. Authenticate with default account admin/icebox. Config- uration is the same as the V2 ICE BOX. APC MASTERSWITCH MODEL AP9606 (network port 23) Attach console cable between laptop running minicom and console port (may be labeled ``advanced port'') at 2400,8n1. Press enter, then authenticate with default account apc/apc. Choose Network from main menu. Choose TCP/IP from Network menu, then diable BOOTP, and accept changes. Set the IP address, subnet mask, and default gateway, and accept changes. Pres ESC until the main menu appears, then select Logout. WTI RPS10 (serial 9600,8n1) Set address of box using the rotary dial on the back. The Master module must be set to address 0. Slave modules may be set to unique val- ues from 1-9. The address corresponds to the plug name in the powerman.conf file. Setup switches on each module should be set to 9600 baud (sw1 down), 5 sec toggle delay (sw2 down), power up to previous state (sw3 down). WTI NPS (network port 23) Attach console cable between laptop running minicom and console port at 9600,8n1. Try password "wti" if prompted. Select /N - View/set network parameters, then set the IP address, subnet mask, and gateway. Select /G - General paramters, then disable command confirmation, enable command echo, and set disconnect timeout to the maximum value (30 minutes). Set password to "wti". CYCLADES PM8 and PM8i (serial 9600,8n1) Attach console cable between laptop running minicom and serial port 9600,8n1. Press enter, then authenticate with default account admin/pm8. Run factory_defaults command. The PM8 can run in a mode where it can be daisy chained from a Cyclades terminal server. This mode is not yet supported by PowerMan. Sun ILOM The dedicated ILOM serial port (SER MGT RJ-45) runs at 9600,8n1 and the default login is root/changeme. Use a Sun/NETRA/Cisco RJ45 adapter to connect to Cyclades TS. The dedicated ILOM ethernet port (NET MGT RJ-45) can be configured for DHCP (the default) or static IP settings. To configure static IP via the ILOM serial port, run: cd /SP/network set pendingipdiscovery=static set pendingipaddress=xxx.xxx.xxx.xxx set pendingipnetmask=xxx.xxx.xxx.xxx set pendingipgateway=xxx.xxx.xxx.xxx set commitpending=true The ILOM network configuration can alternatively be set up via the system BIOS setup screen. Hit F2 during boot to access BIOS setup, go to the "Advanced" tab, select "IPMI 2.0 configuration" and "set LAN configuration". Make your changes and commit them. IPMI (via Ipmipower) IPMI based power control is supported via FreeIPMI's ipmipower. It is configured by running ipmipower in coprocess mode in powerman.conf Due to semantic differences between IPMI and traditional remote power control devices, some power control operations may not seem to work properly by default with Powerman. For example, several IPMI power control operations are allowed to return prior to the operation fully completing. A machine that has been powered off by IPMI may be later queried as being powered on. This is because IPMI may successfully return from a power off operation to the user, but the machine may elect to power itself off at a later time. In order to get around sev- eral of these issues, it is recommended that the user configure ipmipower with the --wait-until-on and --wait-until-off options. With these options set, ipmipower will behave more like traditional remote power control devices. In order to hide IPMI usernames and passwords from ps(1), it is also recommended that the user configure the username and password (and at your discretion, the above options) using the FreeIPMI configuration file and not in the powerman.conf file. Please see the ipmipower sec- tion of the freeipmi.conf(5) manpage for more information. Because IPMI usernames and passwords are sensitive, the default FreeIPMI configuration file is only readable and writable by root. This may conflict with the default powermand daemon settings, thus making the configuration file non-readable. Administrators may wish to run the powermand daemon as root or adjust the configuration file permissions as needed. HP iLO The "hpilo" script supports the Integrated Lights-Out management processor in HP ProLiant servers, including both rack-mount and blade servers. Configure the iLO to allow Telnet access on port 23, and add a user "Admin" with password "Admin". You may have to reduce the minimum password length on the Administration/Access/Options tab of the web interface. HP MP
The "hpmp" script supports the Management Processor in HP non-cellular, rack-mount Integrity servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". If the MP enforces a minimum password length, you may have to use "uc -all default" to restore the default Admin/Admin user. HP MP (cellular) The "hpmpcell" script supports the Management Processor in HP mid-range cellular servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". HP MP (Superdome) The "hpmpdome" script supports the Management Processor in HP Superdome servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". HP MP (Integrity blades) The "hpmpblade" script supports the Management Processor in HP Integrity blade servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". ORIGIN
PowerMan was originally developed by Andrew Uselton on LLNL's Linux clusters. This software is open source and distributed under the terms of the GNU GPL. SEE ALSO
powerman(1), powermand(8), httppower(8), plmpower(8), vpcd(8), powerman.conf(5), powerman.dev(5), powerman-devices(7). http://sourceforge.net/projects/powerman powerman-2.3.5 2009-02-09 powerman-devices(7)