Since your system is running Solaris7, the 'cfgadm' command did not exist back then, and I'm not even certain (without checking) whether 'devfsadm' was even around back then. You'll probably want the do the following on replacement of scsi disks:

Code:
# drvconfig; disks; devlinks

as far as the flags output from 'metadb -i', you're just going to have to wait for a reboot to see the p,l,o and possibly m flags on that disk.
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

multiple disk in sun os

i have unix box , which currently has 2 scsi disk , as shown by format command, one at target 1 and another at target3 (which is current boot disk). can i use both the disk , if so will df -k show usage of both ? can any one guide me how to span file system across multiple disk. i m using sun 5.7... (4 Replies)
Discussion started by: raju
4 Replies

2. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

3. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

4. Emergency UNIX and Linux Support

disk replacment, SUN M3000

we have a SUN M3000 server. setup as only 1 domain. disk c0t0d0 and c0t1d0 and setup as SVM mirrors. a few days ago disk T1 failed. new we have replaced the disk, but can's see the disk in format. have done cfgadm and devfsadm. still can't access the new disk in format. the output... (6 Replies)
Discussion started by: robsonde
6 Replies

5. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

9. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
devfsadm(1M)						  System Administration Commands					      devfsadm(1M)

NAME
devfsadm, devfsadmd - administration command for /dev SYNOPSIS
/usr/sbin/devfsadm [-C] [-c device_class] [-i driver_name] [ -n] [-r root_dir] [-s] [-t table_file] [-v] /usr/lib/devfsadm/devfsadmd DESCRIPTION
devfsadm(1M) maintains the /dev namespace. It replaces the previous suite of devfs administration tools including drvconfig(1M), disks(1M), tapes(1M), ports(1M), audlinks(1M), and devlinks(1M). The default operation is to attempt to load every driver in the system and attach to all possible device instances. Next, devfsadm creates logical links to device nodes in /dev and /devices and loads the device policy. devfsadmd(1M) is the daemon version of devfsadm(1M). The daemon is started during system startup and is responsible for handling both reconfiguration boot processing and updating /dev and /devices in response to dynamic reconfiguration event notifications from the kernel. For compatibility purposes, drvconfig(1M), disks(1M), tapes(1M), ports(1M), audlinks(1M), and devlinks(1M) are implemented as links to devfsadm. In addition to managing /dev, devfsadm also maintains the path_to_inst(4) database. OPTIONS
The following options are supported: -C Cleanup mode. Prompt devfsadm to cleanup dangling /dev links that are not normally removed. If the -c option is also used, devfsadm only cleans up for the listed devices' classes. -c device_class Restrict operations to devices of class device_class. Solaris defines the following values for device_class: disk, tape, port, audio, and pseudo. This option might be specified more than once to specify multiple device classes. -i driver_name Configure only the devices for the named driver, driver_name. -n Do not attempt to load drivers or add new nodes to the kernel device tree. -s Suppress any changes to /dev. This is useful with the -v option for debugging. -t table_file Read an alternate devlink.tab file. devfsadm normally reads /etc/devlink.tab. -r root_dir Presume that the /dev directory trees are found under root_dir, not directly under root (/). No other use or assumptions are made about root_dir. -v Print changes to /dev in verbose mode. EXIT STATUS
The following exit values are returned: 0 Successful completion. 1 An error occurred. FILES
/devices device nodes directory /dev logical symbolic links to /devices /usr/lib/devfsadm/devfsadmd devfsadm daemon /dev/.devfsadm_dev.lock update lock file /dev/.devfsadm_daemon.lock daemon lock file /etc/security/device_policy device policy file /etc/security/extra_privs additional device privileges ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ SEE ALSO
svcs(1), add_drv(1M), modinfo(1M), modload(1M), modunload(1M), rem_drv(1M), svcadm(1M), tapes(1M), path_to_inst(4), attributes(5), privi- leges(5), smf(5), devfs(7FS) NOTES
This document does not constitute an API. The /devices directory might not exist or might have different contents or interpretations in a future release. The existence of this notice does not imply that any other documentation that lacks this notice constitutes an API. devfsadm no longer manages the /devices name space. See devfs(7FS). The device configuration service is managed by the service management facility, smf(5), under the service identifier: svc:/system/device/local:default Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser- vice's status can be queried using the svcs(1) command. SunOS 5.10 6 Aug 2004 devfsadm(1M)
All times are GMT -4. The time now is 01:05 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy