Hi,
I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7).
I extend my vg vg000 (on the partition) and add the 2 hdisks.
I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up.
I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Can you have a Dynamic LPAR without VIO and if yes is there a benefit to having both? I am attempting to implement VIO and Resource pooling at my company and want to understand the limitations.
Also, I have been told the managing and allocation of the Logical Volumes is a time consuming task as... (0 Replies)
We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR.
How can I do it without rebooting the LPARS.
POWER6 with HMC
LPARS = AIX 6.1
Any info
developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ...
But... (5 Replies)
I am wondering if there is a command I can run from **with-in** LPAR server (server01) to find out the hostname or IP address or other parameters for VIO server in charge of server01? (1 Reply)
Just a question which may seem dumb to some out there, but then again I am not a super technie so that's my excuse.
Is it possible to say provision a test AIX LPAR (has a 10gb boot lun and 20gb data) under a VIO which has connectivity to SAN Array A so it can see the disks provisioned to it,... (2 Replies)
Hi
In my vio server I have the below output
$ lsvopt | grep -i SAPSITGS
sapsitgs_cdrom TL12UP.iso 3182
In my vio client lpar I have the below output
root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server
cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies
LEARN ABOUT DEBIAN
roar_vs_stream_obj
roar_vs_connection_obj(3) RoarAudio Programmer's Manual roar_vs_connection_obj(3)NAME
roar_vs_connection_obj, roar_vs_stream_obj, roar_vs_vio_obj - VS API interface for use of main API
SYNOPSIS
#include <roaraudio.h>
struct roar_connection * roar_vs_connection_obj(roar_vs_t * vss, int * error);
struct roar_stream * roar_vs_stream_obj (roar_vs_t * vss, int * error);
struct roar_vio_calls * roar_vs_vio_obj (roar_vs_t * vss, int * error);
DESCRIPTION
Those functions return internal connection, stream and VIO object of the VS object. They are used to use the main API with a VS opened
stream.
roar_vs_connection_obj() returns the connection object used for the control connection to the server.
roar_vs_stream_obj() returns the stream object storing information about the stream.
roar_vs_vio_obj() returns the VIO object used to read data from or send data to the server.
Returned objects are freed as soon as the VS object is closed. If the VS object was created using roar_vs_new_from_con(3) the connection is
not closed by the VS object and stay valid after close until it is closed by the program or library.
The VIO object MUST NOT be used while in buffered mode.
PARAMETERS
vss The VS object to return internal objects from.
error This is a pointer to a integer used to store the error value in case of error. This can be NULL if not used but it is very recom-
mended to use this error value to report good error messages to the user.
RETURN VALUE
On success these calls return the described object. On error, NULL is returned.
EXAMPLES
FIXME
SEE ALSO roarvs(7), libroar(7), RoarAudio(7).
RoarAudio May 2011 roar_vs_connection_obj(3)