Sponsored Content
Full Discussion: Sun/Oracle M5000 Question
Special Forums Hardware Sun/Oracle M5000 Question Post 302610033 by desertdenizen on Tuesday 20th of March 2012 06:06:07 PM
Old 03-20-2012
Sun/Oracle M5000 Question

I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet?

Okay, here's where I am puzzled. Are c0t0, c0t1, c3t0, and c3t1 the on-board HDDs? My supposition is they must be, since c0t3 is the DVD-ROM drive.

Does anyone know for certain? Can someone point me to some documentation that will clarify and define this?

Thanks in advance for all your help.
 

7 More Discussions You Might Find Interesting

1. Solaris

M5000 Question

Hi, I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies

2. Solaris

M5000 Question

Hi i 've a M5000 running 2 domains in my Lab with following hardconf SPARC Enterprise M5000; Memory_Size:128 GB; +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies

3. Solaris

XSCF prompt disappeared, Sun M5000

Hi, I've got an issue here: After I logon to the xscf prompt of this Sun M5000 and did 'XSCF> version -c xcp', the xscf prompt disappeared. I can't get it back and can't log out. exit rebootxscf logout #. #> #> ~# ~# exit sendbreak exit I tried to set the Mode Switch to the service... (3 Replies)
Discussion started by: aixlover
3 Replies

4. UNIX for Advanced & Expert Users

Sun M5000 servers diaster recovery plan

Hi, We have two Sun M5000 systems. A is Oracle server and B is testing server. There are nine Solaris 10 zones set on A. SAN is connecting to A with ZFS configuration. Now we want to set B to be a backup server of A and make the two as identical as possible. No VERITAS cluster, no Solaris... (3 Replies)
Discussion started by: aixlover
3 Replies

5. UNIX for Advanced & Expert Users

Sun M5000 hardware domain creation - How to keep current OS?

Hi, This Sun M5000 currently has a single domain (0) created. Solaris 10 is installed on this domain with some local zones. Now we need to add a secondary hardware domain (1) to this M5000. My question: Can we keep the current OS settings on domain 0 when adding the secondary domain 1? ... (0 Replies)
Discussion started by: aixlover
0 Replies

6. Solaris

Sun M5000 hardware domain creation - How to keep current OS?

Hi, This Sun M5000 currently has a single domain (0) created. Solaris 10 is installed on this domain with some local zones. Now we need to add a secondary hardware domain (1) to this M5000. My question: Can we keep the current OS settings on domain 0 when adding the secondary domain 1? Thank... (5 Replies)
Discussion started by: aixlover
5 Replies

7. Solaris

Sun M5000, xscf showdevices questions

Hi, I've configured this Sun M5000 to use two system domains (added a second domain to it). The following is the info about the settings. The showdevices command can't show devices on domain 1 because Solaris is not loaded on it yet. My question: How can I confirm the hardware devices such as... (5 Replies)
Discussion started by: aixlover
5 Replies
MMCFORMAT(8)						    BSD System Manager's Manual 					      MMCFORMAT(8)

NAME
mmcformat -- format optical media SYNOPSIS
mmcformat [-BDFGHhIMOpRrSsw] [-b blockingnr] [-c cert-num] special DESCRIPTION
The mmcformat utility formats optical media conforming to the MMC standard. This includes CD, DVD, and Blu-Ray (BD) media. The options are as follows: -B Blank media when possible before formatting it. -b blockingnr Explicitly select packet size in sectors (for CD-RW only). It is not recommended to change this from its default of 32. -c cert-num Certify media for DVD-RAM / DV-RE. The argument cert-num specifies: 0 no certification 1 full certification 2 quick certification -D Debug mode. Print all SCSI/ATAPI command errors. -F Format media. -G Grow last CD-RW/DVD-RW session. -H Show help and print formatting choices for the inserted media. -h Show help and print formatting choices for the inserted media. -I Show help and print formatting choices for the inserted media. -M Select MRW (Mount Rainier) error correcting background format. -O Old style CD-RW formatting; recommended for CD-RW. -p Explicitly set packet format. -R Restart previously stopped MCD-MRW or DVD+RW background format. -r Recompile defect list for DVD-RAM. -S Grow spare space DVD-RAM / BD-RE. -s Format DVD+MRW / BD-RE with extra spare space. -w Wait until completion of background format. NOTES
Due to the enormous varieties in optical media, mmcformat is made as generic as possible. This can result in confusion. EXAMPLES
mmcformat -B -O /dev/rcd0d Blanks and then formats a CD-RW disc using the ``old style'' format command. It is recommended to use this ``old style'' command unless your drive reports that it's not supported; in that case, resort to the default -F. Note that a CD-RW disc can be reformatted without being blanked. Blanking switches between sequential and fixed packet writing by erasing the disc. This can also help to revive old discs. mmcformat -F -M /dev/rcd0d Format a CD-RW or a DVD+RW to use MRW (Mount Rainier). This format tries to hide media flaws as much as possible by relocation. SEE ALSO
scsictl(8) HISTORY
The mmcformat command first appeared in NetBSD 5.0. AUTHORS
Reinoud Zandijk <reinoud@NetBSD.org> BUGS
mmcformat could be merged with scsictl(8) but that tool is very hard disk oriented. BSD
May 9, 2008 BSD
All times are GMT -4. The time now is 10:59 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy