Sponsored Content
Operating Systems Linux Red Hat Centos 4 32 bit - New kernel ethX MAC address order issue Post 302605416 by Corona688 on Wednesday 7th of March 2012 11:10:50 AM
Old 03-07-2012
Certainly, but what happens next reboot, replacement, or reordering of PCI slots?

Using custom names means the conflict simply doesn't happen.
 

6 More Discussions You Might Find Interesting

1. IP Networking

How to Achive IP address through MAC(Ethernet) address

Hi sir, i want to make such programe which takes MAC(Ethernet) address of any host & give me its IP address....... but i'm nt getting that how i can pass the MAC address to Frame........ Please give me an idea for making such program... Thanks & regards Krishna (3 Replies)
Discussion started by: krishnacins
3 Replies

2. HP-UX

Change 32 bit to 64 bit Kernel

Hi, I'm using HPUX 11.11 on Vizualize B180L our productive machines have 64 bit kernel # file vmunix vmunix: ELF-64 executable object file - PA-RISC 2.0 (LP64) I got one test system, which should have the same HW (i was told it is the same HW) hpuxtest:/stand-->file... (3 Replies)
Discussion started by: funksen
3 Replies

3. Red Hat

boot the 32 bit kernel on a 64 bit PPC Linux machine?

Hi all, I'm looking to cover a corner case for an upcoming test cycle. Is there a way to boot a RedHat Advanced Server 4 (update 3) installed on a Power PC machine to use a 32 bit kernel? This would be similar to what is done here -> https://www.unix.com/aix/26204-aix-platform.html I've done... (0 Replies)
Discussion started by: philrau
0 Replies

4. Linux

Centos 5 install. Partion order

I can't control the partion order during install. For example i need. hda5 /var 1GB hda6 /opt 2GB I created them in such order but OS adjust them to hda5 /opt 2GB hda6 /var 1GB It is frustrating during install, I pretty sure I can order the partion as i like... (0 Replies)
Discussion started by: honglus
0 Replies

5. Linux

Memory issue on My CentOS 5.8 x64 bit server

Hello, I am using CentOS 5.8 x64 server for our one of internal application which is developed on PHP and Mysql as DB. Currently there are 8-10 instances deployed on this server some of them are rarely used. Below is the H/W specification fort the same :- Procesor :- Intel(R) Xeon(R) CPU ... (6 Replies)
Discussion started by: sunnysthakur
6 Replies

6. IP Networking

MAC Address - Four Interfaces with the same MAC Address

four interfaces with ifconfig all interfaces have the same mac. If is not set for unique. but it still works. what difference does it make to have all macs the same or different? (4 Replies)
Discussion started by: rrodgers
4 Replies
HALT(8) 						Linux System Administrator's Manual						   HALT(8)

NAME
halt, reboot, poweroff - stop the system. SYNOPSIS
/sbin/halt [-n] [-w] [-d] [-f] [-i] [-p] [-h] /sbin/reboot [-n] [-w] [-d] [-f] [-i] /sbin/poweroff [-n] [-w] [-d] [-f] [-i] [-h] DESCRIPTION
Halt notes that the system is being brought down in the file /var/log/wtmp, and then either tells the kernel to halt, reboot or poweroff the system. If halt or reboot is called when the system is not in runlevel 0 or 6, in other words when it's running normally, shutdown will be invoked instead (with the -h or -r flag). For more info see the shutdown(8) manpage. The rest of this manpage describes the behaviour in runlevels 0 and 6, that is when the systems shutdown scripts are being run. OPTIONS
-n Don't sync before reboot or halt. -w Don't actually reboot or halt but only write the wtmp record (in the /var/log/wtmp file). -d Don't write the wtmp record. The -n flag implies -d. -f Force halt or reboot, don't call shutdown(8). -i Shut down all network interfaces just before halt or reboot. -h Put all harddrives on the system in standby mode just before halt or poweroff. -p When halting the system, do a poweroff. This is the default when halt is called as poweroff. DIAGNOSTICS
If you're not the superuser, you will get the message `must be superuser'. NOTES
Under older sysvinit releases , reboot and halt should never be called directly. From release 2.74 on halt and reboot invoke shutdown(8) if the system is not in runlevel 0 or 6. This means that if halt or reboot cannot find out the current runlevel (for example, when /var/run/utmp hasn't been initialized correctly) shutdown will be called, which might not be what you want. Use the -f flag if you want to do a hard halt or reboot. The -h flag puts all harddisks in standby mode just before halt or poweroff. Right now this is only implemented for IDE drives. A side effect of putting the drive in standby mode is that the write cache on the disk is flushed. This is important for IDE drives, since the kernel doesn't flush the write-cache itself before poweroff. The halt program uses /proc/ide/hd* to find all IDE disk devices, which means that /proc needs to be mounted when halt or poweroff is called or the -h switch will do nothing. AUTHOR
Miquel van Smoorenburg, miquels@cistron.nl SEE ALSO
shutdown(8), init(8) Nov 6, 2001 HALT(8)
All times are GMT -4. The time now is 02:16 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy