Sponsored Content
Top Forums Shell Programming and Scripting Expect doesn't recognize a password prompt Post 302605155 by urello on Tuesday 6th of March 2012 06:14:59 PM
Old 03-06-2012
Expect doesn't recognize a password prompt

Hi.
Here is beginning of my script
Code:
#!/usr/local/bin/expect --
set timeout 15
spawn /usr/local/account.sh -n modify
expect "Password:" {send "mypassword\r"}

But due to some terminal control sequences (or something else, dunno exactly) my password prompt is looking like this:
Code:
[[61;157R-n Password:

and expect doesn't recognize it. I tried to use "expect -re" instead of "expect" but no luck. Pls help. OS - Solaris 8
 

9 More Discussions You Might Find Interesting

1. Solaris

correct method to recognize new external DAT drives? and a technical {ok} prompt?

yesterday I attached my external HPsurestore DAT drives to my v440 boxes. one one box, I did a "boot -r" on the other, I did a "drvconfig -vC" the drvconfig was nice, as I didn't have to bounce the box...both systems now recognize associated DAT drives :D I was wondering if these are the... (1 Reply)
Discussion started by: mr_manny
1 Replies

2. Shell Programming and Scripting

Doesn't recognize the mv command

I'm nearly finished my program i've got everything in place and than when i run it it comes back with the reply mv: command not found. This is the code that seems to be causing the problem. elif then echo "There are more than one '$1' files in the system." echo "Please... (2 Replies)
Discussion started by: zoolz
2 Replies

3. UNIX for Advanced & Expert Users

user prompt doesn't pop up with rsh command

Hello All, I'm trying to run some script on other host by using rsh command. This script asking for user id which follows by password requisition. The problem which I faced is that the user requisition prompt never appear. It look like the script is running and wait for the user id to be... (1 Reply)
Discussion started by: ronenalalush
1 Replies

4. HP-UX

HP-UX 11.11: X doesn't recognize mouse and keyboard

hi folks, i've got a blank hp visualize C3000 workstation and installed HP-UX 11.11. When I want to start X, I get the following error message: # X Fatal server error: Couldn't open X pointer device! Is one attached? I've connected an mouse and a keyboard with an usb/ps2 connector.... (5 Replies)
Discussion started by: grisu
5 Replies

5. Solaris

Expired password doesn't prompt for change

I'm on a Solaris 8 box that is not prompting users to change their password after it has expired. I have an older Solaris 8 box that does. We're accessing both via ssh. We have recently built the box that doesn't prompt from scratch. Obviously, we've overlooked something but we don't know what.... (2 Replies)
Discussion started by: mark24p
2 Replies

6. Shell Programming and Scripting

Value of variable is NULL, but test doesn't seem to recognize

Hello, Unix-forums! My problem: read -p "Enter any number, please" number sleep 1 echo $number | tr -d 0-9 test -z $number && echo "Thank you" || echo "This is not a number"Test always displays "This is not a number". It doesn't matter if I entered a or 1. But if I order echo... (2 Replies)
Discussion started by: intelinside
2 Replies

7. Shell Programming and Scripting

Using expect doesn't preserve the stderr

Hello, I am performing the follwing line from a unix server: expect -c 'spawn ssh otherHost chown -R user:group /usr ; expect password: ; send 123456\n ; interact ;' I am getting return value 0, an empty stderr and a stdout that says "/usr/... Not owner, /usr/... Not Owner ..". If I... (2 Replies)
Discussion started by: lastZenMaster
2 Replies

8. Shell Programming and Scripting

Expect script not expecting the password prompt

I have a script that does an SSH into a remote node. It should expect the prompt and send the password. #!/usr/bin/expect set user ; set pass ; spawn ssh $user@E-Internal expect { -re "RSA key fingerprint" {send "yes\r"} timeout... (1 Reply)
Discussion started by: Junaid Subhani
1 Replies

9. IP Networking

DNS problem : ping doesn't recognize hostname

I have vmware on my windows PC ( hostname : acer ). vmware has RHEL 7 ( hostname : rhel7 ) installed recently. RHEL IP configuration IP : 192.168.5.128 Netmask : 255.255.255.0 ssh to rhel7 works from acer using putty resolve.conf cat /etc/resolv.conf nameserver 192.168.5.1 host... (12 Replies)
Discussion started by: hiten.r.chauhan
12 Replies
IRSEND(1)							   User Commands							 IRSEND(1)

NAME
irsend - basic LIRC program to send infra-red commands SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...] DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such as TV boxes, HiFi sets, etc. DIRECTIVE can be: SEND_ONCE - send CODE [CODE ...] once SEND_START - start repeating CODE SEND_STOP - stop repeating CODE LIST - list configured remote items SET_TRANSMITTERS - set transmitters NUM [NUM ...] SIMULATE - simulate IR event REMOTE is the name of a remote, as described in the lircd configuration file. CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file. NUM is the transmitter number of the hardware device. For the LIST DIRECTIVE, REMOTE and/or CODE can be empty: LIST "" "" - list all configured remote names LIST REMOTE "" - list all codes of REMOTE LIST REMOTE CODE - list only CODE of REMOTE The SIMULATE command only works if it has been explicitly enabled in lircd. -h --help display usage summary -v --version display version -d --device use given lircd socket [/var/run/lirc/lircd] -a --address=host[:port] connect to lircd at this address -# --count=n send command n times EXAMPLES
irsend LIST DenonTuner "" irsend SEND_ONCE DenonTuner PROG-SCAN irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3 irsend SEND_STOP OnkyoAmpli VOL-DOWN irsend SET_TRANSMITTERS 1 irsend SET_TRANSMITTERS 1 3 4 irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S" FILES
/etc/lirc/lircd.conf Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave- form details. DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics: "irsend: could not connect to socket" "irsend: Connection refused" (or "Permission denied"). SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory. lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org. irsend 0.9.0-pre1 October 2010 IRSEND(1)
All times are GMT -4. The time now is 06:15 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy