Sponsored Content
Operating Systems HP-UX Remove Faulty disk from HP-UX LVM VG Post 302597436 by Shirishlnx on Friday 10th of February 2012 09:58:15 AM
Old 02-10-2012
Sorry for confusion..!!

This is a test environment on which am testing the clone behavior .. initially on this server 2 hdd with 1 vg00.. which was in mirrored state . have tested server was able to boot on either of single disk ..

Then.. have inserted a new disk and build a new mirrored disk ..bootable ... then without any proper reduce .. have removed that disk and rebooted the server and now am trying to remove the error that am getting with vgdisplay ..

I believe have done some wrong step to reduce the VG and LV mirror path for new disk (that had removed ) and now mirroring is totally broken ... only primary disk is active now now ..

From here I want to ... remove all error from VG and rebuilt the mirroring i.e. as rollback the server it it's initial state ..

Guide me how I can remove all above error (1st Thread) from this server
 

10 More Discussions You Might Find Interesting

1. HP-UX

disk adding through lvm

Hi dear(s) Can u explain how to add a disk through lvm with commands. I need to add a 9 gb scsi HS disk to a Hp D class 9000 server. (2 Replies)
Discussion started by: sreekumar.R
2 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. AIX

Disk I/O Issue using LVM

We have a filesystem which contains 8 hard disks but i am facing disk I/O issue becuase data is not spreading across all the disks.Is there any way i can check how data is spreading and any parameter we need to change to spread ata across all disks. OS--AIX 5.3 (1 Reply)
Discussion started by: ukatru
1 Replies

4. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

7. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

8. UNIX for Advanced & Expert Users

LVM - restore metadata on other disk

Hi guys, I would like to ask your opinion about my theory, how to fix my broken LVM without risking any data loss. I use Archlinux at home. I just love this distro, even it gives me a lots of work (particularly after system updates). Basic system spec: AMD FX(tm)-6100 Six-Core Processor... (1 Reply)
Discussion started by: lyynxxx
1 Replies

9. HP-UX

LVM: is possible to replace a disk?

Scenario1: VG00 lvm,not mirrored,2 disk of 36GB vg size VG00 size is under 30G. Is possible to remove a disk of 36GB and replace "on fly" with a disk of 300GB on VG00? Thanks (6 Replies)
Discussion started by: Linusolaradm1
6 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
info(4) 						     Kernel Interfaces Manual							   info(4)

NAME
info - diskless client configuration information file DESCRIPTION
The file is a POSIX shell sourceable file which contains parameter definitions used at boot time. Typically, it will be an empty file and default values will be used for all parameters. Following is the list of parameters which can be defined in the file: Specifies the IP address of the client's private root server. If this is not specified, the client's private root server defaults to the boot server. Specifies the pathname to the client's private root on the private root server. If this is not specified, the client's private root path defaults to Specifies the NFS mount options to mount the client's private root from the private root server. If this is not specified, the mount options default to Specifies the NFS mount options to mount the client's directory from the boot server. If this is not specified, the mount options default to Specifies whether NFS should be configured as primary swap. (NOTE: In order to swap to NFS, a diskless kernel must be configured with tunable parameter set to 1.) If a diskless machine has a local swap disk and swap to NFS is not desired, the parameter should be set to the value of 1 and the diskless kernel should be configured without setting to 1. If this parameter is not specified in the file and the kernel tunable parameter is set to 1, then NFS will be configured as primary swap. If not set, this parameter defaults to a value of 1, and results in the removal of all swapfiles above the configured swap minimum (swap is specified in the client's when a disk- less client boots. This ensures that extraneous swapfiles at boot time are removed, thus freeing disk space. If is set to 0 in the file, removal of extra swapfiles is disabled. This may result in faster boot times due to the time savings in creating additional swap files. The file resides in the same directory as the client's kernel () on the boot server and is retrieved at boot time using command. By default, when a diskless client is created, an empty file is placed in the client's kernel directory. This ensures that all parameters revert to their default values (see above). If the file is not present, this is an error. EXAMPLES
An example file is shown below: FILES
info(4)
All times are GMT -4. The time now is 12:46 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.