When I started mirroring the VG00 on my new disk, the system had already 2 disk in mirrored state ... At that time my mirror value was 1, so while mirroring 3rd disk have used -m 2 .. and my # lvlnboot -v shows all boot order without error .
Then have removed my 3rd disk directly.. without spilting or reducing vg ..
After that had ran above cmnds .. and get stuck .. As I understand now current state is my all mirrored got failed .. only 1 active boot disk is there ... it may be bcz have done wrong vg reduce or lvreduce ..
## Now what I want is to .. remove what error am getting then remirror this OS on second disk .. to safely handover this server ...
Hi Experts,
I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics.
pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D
SSA160 Physical Disk Drive ( MB)
Is there a way to stop this... (2 Replies)
We have a filesystem which contains 8 hard disks but i am facing disk I/O issue becuase data is not spreading across all the disks.Is there any way i can check how data is spreading and any parameter we need to change to spread ata across all disks.
OS--AIX 5.3 (1 Reply)
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Hi,
Have mirrored the primary disk to 3 .
Server and OS:
# uname -a
HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license
# model
9000/800/L3000-7x
# strings /etc/lvmtab
/dev/vg00
+F@<
/dev/dsk/c1t2d0
/dev/dsk/c2t2d0
/dev/dsk/c2t0d0
But now I have only 1 disk... (5 Replies)
Hello,
I'm new to this forum and as you will see from my question I'm new to UNIX as well.
One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Hi guys,
I would like to ask your opinion about my theory, how to fix my broken LVM without risking any data loss.
I use Archlinux at home. I just love this distro, even it gives me a lots of work (particularly after system updates).
Basic system spec:
AMD FX(tm)-6100 Six-Core Processor... (1 Reply)
Scenario1:
VG00 lvm,not mirrored,2 disk of 36GB vg size
VG00 size is under 30G.
Is possible to remove a disk of 36GB and replace "on fly"
with a disk of 300GB on VG00?
Thanks (6 Replies)
I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply)
-> show faulty
Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
LEARN ABOUT OSF1
volreattach
volreattach(8) System Manager's Manual volreattach(8)NAME
volreattach - Reattaches disk drives that have once again become accessible
SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...]
/usr/sbin/volreattach -c accessname
OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the
failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the
name of the disk group and disk media name at which the disk can be reattached is displayed.
DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment.
This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical
Storage Manager is started, causing disks to enter the failed state.
If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the
reattach happens before any volumes on the disk are started.
The volreattach command is called from the voldiskadm menus as part of disk recovery.
The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching
disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists.
EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned.
SEE ALSO volintro(8), voldiskadm(8), volrecover(8)volreattach(8)