Sponsored Content
Operating Systems HP-UX Remove Faulty disk from HP-UX LVM VG Post 302597151 by Shirishlnx on Thursday 9th of February 2012 10:51:44 AM
Old 02-09-2012
Code:
# ioscan -funC disk
Class     I  H/W Path        Driver   S/W State   H/W Type     Description
===========================================================================
disk     41  0/0/1/1.0.0     sdisk    CLAIMED     DEVICE       HP 36.4GST336753LC
                            /dev/dsk/c1t0d0   /dev/rdsk/c1t0d0
disk      0  0/0/1/1.2.0     sdisk    CLAIMED     DEVICE       HP 36.4GST336753LC
                            /dev/dsk/c1t2d0   /dev/rdsk/c1t2d0
disk      1  0/0/2/0.2.0     sdisk    CLAIMED     DEVICE       HP 36.4GST336753LC
                            /dev/dsk/c2t2d0   /dev/rdsk/c2t2d0
disk      2  0/0/2/1.2.0     sdisk    CLAIMED     DEVICE       HP      DVD-ROM 305
                            /dev/dsk/c3t2d0   /dev/rdsk/c3t2d0
disk      3  0/10/0/0.1.0.0.0.0.0  sdisk    CLAIMED     DEVICE       HP      A6189B
                            /dev/dsk/c4t0d0   /dev/rdsk/c4t0d0


Last edited by methyl; 02-09-2012 at 12:05 PM.. Reason: code tags
 

10 More Discussions You Might Find Interesting

1. HP-UX

disk adding through lvm

Hi dear(s) Can u explain how to add a disk through lvm with commands. I need to add a 9 gb scsi HS disk to a Hp D class 9000 server. (2 Replies)
Discussion started by: sreekumar.R
2 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. AIX

Disk I/O Issue using LVM

We have a filesystem which contains 8 hard disks but i am facing disk I/O issue becuase data is not spreading across all the disks.Is there any way i can check how data is spreading and any parameter we need to change to spread ata across all disks. OS--AIX 5.3 (1 Reply)
Discussion started by: ukatru
1 Replies

4. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

7. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

8. UNIX for Advanced & Expert Users

LVM - restore metadata on other disk

Hi guys, I would like to ask your opinion about my theory, how to fix my broken LVM without risking any data loss. I use Archlinux at home. I just love this distro, even it gives me a lots of work (particularly after system updates). Basic system spec: AMD FX(tm)-6100 Six-Core Processor... (1 Reply)
Discussion started by: lyynxxx
1 Replies

9. HP-UX

LVM: is possible to replace a disk?

Scenario1: VG00 lvm,not mirrored,2 disk of 36GB vg size VG00 size is under 30G. Is possible to remove a disk of 36GB and replace "on fly" with a disk of 300GB on VG00? Thanks (6 Replies)
Discussion started by: Linusolaradm1
6 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 05:52 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy