Sponsored Content
Full Discussion: disk replacment, SUN M3000
Homework and Emergencies Emergency UNIX and Linux Support disk replacment, SUN M3000 Post 302594998 by DukeNuke2 on Wednesday 1st of February 2012 07:40:27 PM
Old 02-01-2012
strange... are there entries in /dev/dsk/... for the disk?
This User Gave Thanks to DukeNuke2 For This Post:
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

multiple disk in sun os

i have unix box , which currently has 2 scsi disk , as shown by format command, one at target 1 and another at target3 (which is current boot disk). can i use both the disk , if so will df -k show usage of both ? can any one guide me how to span file system across multiple disk. i m using sun 5.7... (4 Replies)
Discussion started by: raju
4 Replies

2. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

3. Solaris

SUN T5240 vs M3000

Hi, We are planning to buy new server for our data center. Sun T5240 or M3000 which one have better performance, we are going to create many dt sessions in this server. So, i need your suggestions. RJS (4 Replies)
Discussion started by: rajasekg
4 Replies

4. Solaris

XSCF on M3000

Hi, I've updated a few M3000s to new firmware without any hassle, but on one of them the following is happening: XSCF> getflashimage -u wayner ftp://10.16.122.200/tftpboot/IKXCP1102.tar.gz Error: insufficient free space Any idea how to delete whatever old firmware is on there so I can... (7 Replies)
Discussion started by: cabaiste
7 Replies

5. SCO

sco 5.0.5 5.0.6 openscource replacment ?

is there a version of anything linux distro that could clone/emulate sco close enough to run the 1 software program we keep this server for ? boil this question down some if a program is running on a sco system now are there any alternatives ? (2 Replies)
Discussion started by: crosbymook
2 Replies

6. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

7. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies

8. UNIX for Beginners Questions & Answers

Help with sed replacment

Hi All, I am new to Unix and have a simple question. I would like to do three sed replacements in a large text file. The command I am using is as follows.... sed –n –e ‘s/:A/:X/’ –e ‘s/:B/:Y/’ –e ‘s/:C/:Z/’ myfile.txt > myfile_SED.txt The : need to be the search to identify specific :A, :B,... (3 Replies)
Discussion started by: landrjos
3 Replies
volreattach(8)						      System Manager's Manual						    volreattach(8)

NAME
volreattach - Reattaches disk drives that have once again become accessible SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...] /usr/sbin/volreattach -c accessname OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the name of the disk group and disk media name at which the disk can be reattached is displayed. DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment. This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical Storage Manager is started, causing disks to enter the failed state. If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the reattach happens before any volumes on the disk are started. The volreattach command is called from the voldiskadm menus as part of disk recovery. The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists. EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned. SEE ALSO
volintro(8), voldiskadm(8), volrecover(8) volreattach(8)
All times are GMT -4. The time now is 01:11 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy