We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist?
Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer.
thanks (4 Replies)
Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
I have seen a few threads / posts on the forum's but nothing specific to what Iam after. So Iam hoping you can help.
Issue : Iam hoping to remove unused emc luns from my solaris servers , T2000 (5.10 Generic_142900-02). I have a list of the process I have followed for the removal of the luns.... (3 Replies)
Hello all,
i try to allocate the same LUN to two server (or more in the future)
i use solaris 10, vxvm (vxfs) for data and solaris zones and EMC DMX-4, i try to migrate solaris zones between servers in case of problem.
and this is what i want to do
- affect LUN to srv00124 and srv10155
-... (5 Replies)
It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Hi,
We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs.
The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Hi Community,
I am facing one issue related storage accessing from solaris 10 machine(M5000). it was working fine then we shifted to another site. the only change on that site is FC switch.
The issue i am facing is from solaris machine i can able to see the LUN, it;s only a test lun of 30... (17 Replies)
Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this :
lslpp -l | grep EMC
... (7 Replies)
we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)