One emc powerpath failed


 
Thread Tools Search this Thread
Operating Systems Solaris One emc powerpath failed
# 1  
Old 10-24-2013
One emc powerpath failed

It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I assume that if cable is defective or not connected, it should say "NOT CONNECTED". Why other path is not visible here ?
Code:
root@dbpautp02 # luxadm -e port
/devices/pci@400/pci@2/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0:devctl  CONNECTED
/devices/pci@400/pci@2/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0,1/fp@0,0:devctl  NOT CONNECTED
/devices/pci@500/pci@1/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0,1/fp@0,0:devctl  NOT CONNECTED
root@dbpautp02 # luxadm -e dump_map /devices/pci@400/pci@2/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0:devctl
Pos  Port_ID Hard_Addr Port WWN         Node WWN         Type
0    c92c0   0         500009720805fd50 500009720805fc00 0x0  (Disk device)
1    c7800   0         10000000c9dfde8c 20000000c9dfde8c 0x1f (Unknown Type,Host Bus Adapter)
root@dbpautp02 # cfgadm -al | grep -i fc-fabric
c5                             fc-fabric    connected    configured   unknown
root@dbpautp02 # powermt display paths
Symmetrix logical device count=9
==============================================================================
----- Host Bus Adapters --------- ------ Storage System -----    - I/O Paths -
###  HW Path                         ID           Interface     Total    Dead
==============================================================================
3078 pci@400/pci@2/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0     000192600383     FA  5fA           9       0
root@dbpautp02 #

I have other similar hardware server, that is fine, which shows as below
Code:
root@dbpautp01 # powermt display paths
Symmetrix logical device count=10
==============================================================================
----- Host Bus Adapters --------- ------ Storage System -----    - I/O Paths -
###  HW Path                         ID           Interface     Total    Dead
==============================================================================
3076 pci@500/pci@1/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0     000192600383     FA  5fA          10       0
3080 pci@400/pci@2/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0     000192600383     FA 12fA          10       0
root@dbpautp01 # luxadm -e dump_map /devices/pci@400/pci@2/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0:devctl
Pos  Port_ID Hard_Addr Port WWN         Node WWN         Type
0    b92c0   0         500009720805fd6c 500009720805fc00 0x0  (Disk device)
1    b95c0   0         10000000c9dfdea8 20000000c9dfdea8 0x1f (Unknown Type,Host Bus Adapter)
root@dbpautp01 # luxadm -e dump_map /devices/pci@500/pci@1/pci@0/pci@1/pci@0/pci@3/SUNW,emlxs@0/fp@0,0:devctl
Pos  Port_ID Hard_Addr Port WWN         Node WWN         Type
0    c92c0   0         500009720805fd50 500009720805fc00 0x0  (Disk device)
1    c95c0   0         10000000c9dfd7a8 20000000c9dfd7a8 0x1f (Unknown Type,Host Bus Adapter)
root@dbpautp01 #

Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Solaris

Emc powerpath device & zfs query

Hi, We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs. The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies

2. Solaris

Powerpath upgrade with SVM disksets

Hi all I am running the following hardware: 2 SUN Solaris 10 machines They are connected to EMC clarion LUNs We are running a Sun Cluster 3.2 managing both nodes We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies

3. Linux

EMC, PowerPath and issue on using LUN

Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3. I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process: echo "1" > /sys/class/fc_host/host<n>/issue_lip and echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies

4. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

5. Solaris

Migrate from MPXIO to Powerpath

Here is the issue: I am building a database server using Solaris 10x86 U8. The system is jumpstarted with mpxio enabled and booting from the san. We need to have powerpath 5.3 installed and would like to have powerpath take control of the the boot san as well or have mpxio control the san... (2 Replies)
Discussion started by: nabru72
2 Replies

6. Solaris

Solaris 10 with Veritas and PowerPath

Hello, I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN. This is the situation : Server is a SUN Enterprise M5000 OS = Solaris10 Sparc Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies

7. Red Hat

Configure EMC Powerpath?

Hi , I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies

8. AIX

Cannot uninstall powerpath - bosboot issues

Hi Guys, I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one. I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors: ... (4 Replies)
Discussion started by: zxmaus
4 Replies

9. Solaris

change SP value in powerpath

How to change the following values in power path from SP B to SP A ? Owner: default=SP B, current=SP B this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies

10. Filesystems, Disks and Memory

Can Veritas DMP & EMC PowerPath coexist?

We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist? Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies
Login or Register to Ask a Question