Simply put, we don't have support for this storage (at least for that, only for incidents), at least that's what I've being told Smilie .
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Can Veritas DMP & EMC PowerPath coexist?

We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist? Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies

2. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

3. Red Hat

Configure EMC Powerpath?

Hi , I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies

4. UNIX for Advanced & Expert Users

Removing EMC LUN from Solaris 10 host without a reboot

I have seen a few threads / posts on the forum's but nothing specific to what Iam after. So Iam hoping you can help. Issue : Iam hoping to remove unused emc luns from my solaris servers , T2000 (5.10 Generic_142900-02). I have a list of the process I have followed for the removal of the luns.... (3 Replies)
Discussion started by: furby
3 Replies

5. Solaris

Solaris/vxvm/EMC Lun configuration

Hello all, i try to allocate the same LUN to two server (or more in the future) i use solaris 10, vxvm (vxfs) for data and solaris zones and EMC DMX-4, i try to migrate solaris zones between servers in case of problem. and this is what i want to do - affect LUN to srv00124 and srv10155 -... (5 Replies)
Discussion started by: mat_solaris
5 Replies

6. Solaris

One emc powerpath failed

It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies

7. Solaris

Emc powerpath device & zfs query

Hi, We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs. The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies

8. Solaris

Solaris OS having issue accessing LUN from Qlogic swich

Hi Community, I am facing one issue related storage accessing from solaris 10 machine(M5000). it was working fine then we shifted to another site. the only change on that site is FC switch. The issue i am facing is from solaris machine i can able to see the LUN, it;s only a test lun of 30... (17 Replies)
Discussion started by: bentech4u
17 Replies

9. AIX

AIX Migration issue with EMC ODM sets

Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this : lslpp -l | grep EMC ... (7 Replies)
Discussion started by: JME2015
7 Replies

10. AIX

AIX help -reconnect EMC lun

we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
MYSQLND_QC_SET_STORAGE_HANDLER(3)					 1					 MYSQLND_QC_SET_STORAGE_HANDLER(3)

mysqlnd_qc_set_storage_handler - Change current storage handler

SYNOPSIS
bool mysqlnd_qc_set_storage_handler (string $handler) DESCRIPTION
Sets the storage handler used by the query cache. A list of available storage handler can be obtained from mysqlnd_qc_get_available_han- dlers(3). Which storage are available depends on the compile time configuration of the query cache plugin. The default storage handler is always available. All other storage handler must be enabled explicitly when building the extension. PARAMETERS
o $handler - Handler can be of type string representing the name of a built-in storage handler or an object of type mysqlnd_qc_han- dler_default. The names of the built-in storage handler are default, APC, MEMCACHE, sqlite. RETURN VALUES
Returns TRUE on success or FALSE on failure. If changing the storage handler fails a catchable fatal error will be thrown. The query cache cannot operate if the previous storage han- dler has been shutdown but no new storage handler has been installed. EXAMPLES
Example #1 mysqlnd_qc_set_storage_handler(3) example The example shows the output from the built-in default storage handler. Other storage handler may report different data. <?php var_dump(mysqlnd_qc_set_storage_handler("memcache")); if (true === mysqlnd_qc_set_storage_handler("default")) printf("Default storage handler activated"); /* Catchable fatal error */ var_dump(mysqlnd_qc_set_storage_handler("unknown")); ?> The above examples will output: bool(true) Default storage handler activated Catchable fatal error: mysqlnd_qc_set_storage_handler(): Unknown handler 'unknown' in (file) on line (line) SEE ALSO
Installation, mysqlnd_qc_get_available_handlers(3). PHP Documentation Group MYSQLND_QC_SET_STORAGE_HANDLER(3)
All times are GMT -4. The time now is 06:47 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy