We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist?
Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer.
thanks (4 Replies)
Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
I have seen a few threads / posts on the forum's but nothing specific to what Iam after. So Iam hoping you can help.
Issue : Iam hoping to remove unused emc luns from my solaris servers , T2000 (5.10 Generic_142900-02). I have a list of the process I have followed for the removal of the luns.... (3 Replies)
Hello all,
i try to allocate the same LUN to two server (or more in the future)
i use solaris 10, vxvm (vxfs) for data and solaris zones and EMC DMX-4, i try to migrate solaris zones between servers in case of problem.
and this is what i want to do
- affect LUN to srv00124 and srv10155
-... (5 Replies)
It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Hi,
We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs.
The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Hi Community,
I am facing one issue related storage accessing from solaris 10 machine(M5000). it was working fine then we shifted to another site. the only change on that site is FC switch.
The issue i am facing is from solaris machine i can able to see the LUN, it;s only a test lun of 30... (17 Replies)
Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this :
lslpp -l | grep EMC
... (7 Replies)
we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
LEARN ABOUT HPUX
format
format(1M)format(1M)NAME
format - format an HP SCSI disk array LUN
SYNOPSIS
device_file
DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format,
in which the controller writes zeroes to the data area and parity area, if any, of the LUN.
NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a
regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol-
lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows:
1. The controller received a Mode Select command which requires a drive sector size change.
2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03).
3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives
will be formatted.
4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set.
RETURN VALUE
returns the following values:
0 Successful completion.
-1 Command failed.
DIAGNOSTICS AND ERRORS
Errors can originate from problems with:
o
o SCSI (device level) communications
o system calls
Error messages generated by format:
An error in command syntax has occurred.
Enter command again with all required arguments, in the order shown.
To ensure that
does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the
disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by
the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to
deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)).
The LUN number, which is derived from the device file name, is out of range.
The addressed LUN
is not configured, and thus is not known to the array controller.
Utilities must be able to open the device file for raw access.
The device being addressed is not an HP SCSI disk array.
SCSI (device level) communication errors:
Sense data associated with the failed operation is printed.
Error messages generated by system calls:
uses the following system calls:
and
Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not
alter the value of The interpretation of for printing purposes is performed by the system utility
EXAMPLES
To format the HP SCSI disk array LUN on a Series 800:
WARNING
The command will destroy all user data on the addressed LUN.
DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X.
The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X.
AUTHOR
was developed by HP.
format(1M)