Hi All,
I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV.
My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Hi,
I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers?
Thanks,
Ronald (2 Replies)
Hello,
I do not know if this is the right title to use. I have a large dictionary database which has the following structure:
where a b c d e are in English and p q r s t are in a target language., the two separated by the delimiter =.
What I am looking for is a perl script which will take... (5 Replies)
If you're familiar with vscsi mappings thru a VIO Server, you are probably aware, on an AIX 6.1 Client LPAR, that:
print cvai | kdbcan provide useful information to you.... like VIO Server name & vhost #. But, "cvai" does not appear to be part of the Kernel Debugger in AIX 5.3.
My question is... (3 Replies)
Hello Friends,
My question/problem is that I noticed 2 servers in my environment vscsi is showing up as defined (not available) or is defined and not showing the path to both vscsi's when ruining lspath command. I am new to AIX admin, work alone, and work in an small environment. My question is,... (12 Replies)
Some storage/disks have been added to an existing AIX 6.1 server. The admin sent me the list of hdisk#'s for the new disks, but I need the corresponding rhdisk# for the same hdisk. (I know from past experience that the rhdisk that maps to an hdisk is not always the same number. For instance,... (5 Replies)
Hello,
When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar
#cfgmgr
cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed.
devices.vscsi.disk
searching... (0 Replies)
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Hi,
We had a hardware problem with an IBM System p5 server, with AIX 5.2
We restore from a tape the last backup we had, but the server does not boot up as expected.
The server try to mount some directories from a storage, but could not comunicate with them, we check the FC and everything is... (12 Replies)
Discussion started by: trevian3969
12 Replies
LEARN ABOUT DEBIAN
arch::liteweb
Arch::LiteWeb(3pm) User Contributed Perl Documentation Arch::LiteWeb(3pm)NAME
Arch::LiteWeb - simple way to access web pages
SYNOPSIS
my $web = Arch::LiteWeb->new;
my $content = $web->get("http://some.domain:81/some/path");
die $web->error . " while processing " . $web->request_url
unless $content;
my $content_type = $web->response_headers->{content_type};
DESCRIPTION
This class provides a basic and easy to use support for the client-side HTTP. It is supplied in order to avoid dependency on LWP. If such
dependency is not a problem, consider to use LWP instead that provides much better support for HTTP and other protocols.
METHODS
The following class methods are available:
get, post, request_url, error, error_with_url, network_error, response_code, response_codestr, response_error, response_headers,
response_content.
get url [params ...]
Execute HTTP get of the given url and return the html string or undef on network/response error. Use other methods to get the details
about the error and the response.
params is key-value hash, the following keys are supported:
url_host - only used if url is none
url_port - only used if url is none(80)
url_path - only used if url is none
endl - default is "