Sponsored Content
Full Discussion: Useful Hardware commands
Special Forums Hardware Useful Hardware commands Post 302577556 by Corona688 on Tuesday 29th of November 2011 10:33:12 AM
Old 11-29-2011
I don't even have /etc/sysconfig... redhat is not the universe...

Something that does exist under all (modern) Linux is the special /sys/ folder. It's a virtual folder like /proc/ which holds no real files, but there's all sorts of information buried in there.

Code:
# Mac addresses for each network interface
for D in /sys/class/net/*
do
        [ "$D" = "/sys/class/net/lo" ] && continue
        [ "$D" = "/sys/class/net/sit0" ] && continue
        printf "%s\t%s\n" "${D}" "`cat ${D}/address`"
done

# Models of disk drives on the system
for D in /sys/class/block/sd[a-z] /sys/class/block/sr[0-9] /sys/class/block/hd[a-z]
do
        [ -e "$D" ] || continue
        printf "%s\t%s\n" $D "`cat "$D"/device/model`"
done

 

10 More Discussions You Might Find Interesting

1. UNIX Desktop Questions & Answers

hardware 3d

How do I check my system to see if the graphics are using hardware 3d suport or not. I have a TNT2 on RH 7.1 kernel 2.4.9-?(can't remember off top of my head)I'm running all the latest updates from RH. Also I now have a dvd drive and I am trying to find a player that will play all movies and not... (1 Reply)
Discussion started by: MaxCat
1 Replies

2. AIX

AIX and SUN unix commands for hardware monitoring

Hello again, I would like to know if the following commands: diag, errpt, lscfg, lspv, lsvg, lsps, lslv for AIX and prtdiag, psrinfo, sysdef for SUN are native to these systems or if they are in fact scripts that are added after the unix installation. Thank you in advance. Have a nice day (4 Replies)
Discussion started by: VeroL
4 Replies

3. HP-UX

HPUX Hardware commands.

HI ALL, I am new tp HPUX and i am looking for command that will retive me the following information on HPUX: Chassis Name & Serial Number: Monitor Name BIOS Name EthernetPort Name IPEndpoint Name PointingDevice Name Keyboard NetworkPrinter Name LocalPrinter (5 Replies)
Discussion started by: Veenak15
5 Replies

4. AIX

AIX Hardware commands

Hi All, Needed commands to find Monitor , chassis & keyboard related information on AIX. Please please please help. Thanks VK (2 Replies)
Discussion started by: Veenak15
2 Replies

5. Programming

code that reads commands from the standard i/p and executes the commands

Hello all, i've written a small piece of code that will read commands from standard input and executes the commands. Its working fine and is execting the commands well. Accepting arguments too. e.g #mkdir <name of the directory> The problem is that its not letting me change the directory i.e... (4 Replies)
Discussion started by: Phrozen Smoke
4 Replies

6. Shell Programming and Scripting

Can BASH execute commands on a remote server when the commands are embedded in shell

I want to log into a remote server transfer over a new config and then backup the existing config, replace with the new config. I am not sure if I can do this with BASH scripting. I have set up password less login by adding my public key to authorized_keys file, it works. I am a little... (1 Reply)
Discussion started by: bash_in_my_head
1 Replies

7. Solaris

commands hanging when querying hardware

Hi all Got another strange one. If I try to enquire about the hardware, the command hangs implying Ive got a hardware issue. So, if I execute :- iostat -en sysdef - ( stops at the devices part ) format cfgadm -al Anything that searches the devices, then the command hangs. ... (4 Replies)
Discussion started by: sbk1972
4 Replies

8. AIX

New Hardware

Can someone help me with what I am guessing is a simple job for an AIX admin. However I am 100% HP-UX and not touched AIX before the start of this week. I am trying to connect an IBM Blade (JS22) to our HP Enterprise Tape Library. I have done all the SAN zoning and this appears to be happy... (5 Replies)
Discussion started by: Andyp2704
5 Replies

9. AIX

HACMP: difference between 'cl' commands and 'cli' commands

Hi all, I'm new in this forum. I'm looking for the difference between the HACMP commands with the prefix "cl" and "cli". The first type are under /usr/es/sbin/cluster/sbin directory and the second are under /usr/es/sbin/cluster/cspoc directory. I know that the first are called HACMP for AIX... (0 Replies)
Discussion started by: peppix
0 Replies

10. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g,. hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree Linux 2012-08-05 HPSA(4)
All times are GMT -4. The time now is 07:18 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy