Sponsored Content
Full Discussion: Fsck with SVM
Operating Systems Solaris Fsck with SVM Post 302577147 by vishalaswani on Monday 28th of November 2011 09:43:03 AM
Old 11-28-2011
Hello,

We don't run fsck on mounted filesystem.

In SVM, devices are not created the way you have mentioned, meta devices are named as d0, d1, d12 etc... 'd' followed by a number.

Consider the below example:

d11 - c0t0d0s0
d12 - c0t1d0s0

d10 is a mirrored metadevice with d11 and d12 as its sub mirror.

You will mount d10 after creating a filesystem on it for any use.

In case you want to run fsck on it or its sub mirrors, then you first need to unmount it and then run fsck accordingly.

fsck /dev/md/rdsk/d10
fsck /dev/md/rdsk/d11
fsck /dev/md/rdsk/d12

Hope this helps.

Regards,
Vishal
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

fsck -y

Once in a while, I would think it advisable to run fsck -y to check the disk. Should I sign in as su or sudo? What is the difference and which is preferred? Thank you in Advance! (4 Replies)
Discussion started by: rpatrick
4 Replies

2. Solaris

fsck

OS: Solaris 5.8 Everytime I run fsck -y I get: FILE SYSTEM STATE IN SUPERBLOCK IS WRONG; FIX? yes Do I need to run fsck with the backup superblock option or is there some other option I should use. I have tried the format->analyze->read option but that does not report any corrupt blocks.... (5 Replies)
Discussion started by: run_time_error
5 Replies

3. UNIX for Dummies Questions & Answers

fsck - what should be done?

I want to use fsck to check and repair my linux system. When I use this command, what do I need to pay attention to or what should I do to make job running successfully. Thanks for your inputs for a newbie. (3 Replies)
Discussion started by: duke0001
3 Replies

4. Solaris

fsck -o

Hello I am getting this in dmesg: /mount1: unexpected free inode 1262865, run fsck(1M) -o f What are the options I should use with fsck? thanks (2 Replies)
Discussion started by: melanie_pfefer
2 Replies

5. UNIX for Dummies Questions & Answers

about fsck

i want to know what does it mean by doing a consistentcy check fsck on a disk and why journaling filesystems dont need to do it and what is meant by disk is in a consistent state when writing because entries are recorded in a journal and then to the metadata and then removed from journal (1 Reply)
Discussion started by: farhan_t49
1 Replies

6. Solaris

fsck issue

I am not able to boot into solaris. I am getting following message. The / file system (/dev/rdsk/c0t0d0s0) is being checked. Warning - Unable to repair the / filesystem. Run fsck manually(fsck -F ufs /dev/rdsk/c0t0d0s0). I ran fsck manually but it didn't work. Help from anyone would be... (1 Reply)
Discussion started by: likhitgatagat
1 Replies

7. Solaris

Urgent !! SVM, subdisks "UNEXPEXTED INCONSITENCY; RUN fsck MANUALLY

Hi, I am getting this error while server booting up, not sure how to fix this. Unable to mount these file systems /dev/md/rdsk/d51: No such device or address Can't open /dev/md/rdsk/d51: No such device or address /dev/md/rdsk/d51: CAN'T CHECK FILE SYSTEM. /dev/md/rdsk/d51: UNEXPECTED... (1 Reply)
Discussion started by: bobby320
1 Replies

8. Solaris

fsck - how to know if required or not

Hello Friends, My doubt is 1) How do we know if we need Fsck to run or not can we check using any switch so that we can know if our filesystem really requires to run fsck or not?? (2 Replies)
Discussion started by: saurabh84g
2 Replies

9. Solaris

unable to repair the / filesystem. Run fsck manually (fsck -F ufs /dev/rdsk/c1t0d0s0)

What can I fix this issue? I have ran below commands but everything is same.:confused: WARNING: Last shutdown is later than time on time-of-day chip: check date. The / file system (/dev/rdsk/c1t0d0s0) is being checked WARNING - unable to repair the / filesystem. Run fsck manually (fsck -F... (4 Replies)
Discussion started by: getrue
4 Replies

10. Solaris

Fsck in vxvm

Hi, When we are running fsck in vxvm FS within few sec it will completed even if data is more than 500GB or in TB also. compare to UFS FS in that it will take more time compare with vxvm.UFS check FS in block level. & then vvxm on where its checking the FS. Please explain. (1 Reply)
Discussion started by: tiger09
1 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated disk driver SYNOPSIS
pseudo-device ccd [count] DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you're familiar with how to generate kernels, how to properly configure disks and pseudo-devices in a kernel con- figuration file, and how to partition disks. Note that the 'raw' partitions of the disks must not be combined. Each component partition should be offset at least one cylinder from the beginning of the component disk. This avoids potential conflicts between the component disk's disklabel and the ccd's disklabel. The kernel will only allow component partitions of type FS_CCD. But for now, it allows partition of all types since some port lacks support of an on- disk BSD disklabel. The partition of FS_UNUSED may be rejected because device driver of component disk will refuse it. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: pseudo-device ccd 4 # concatenated disk devices The count argument is how many ccds memory is allocated for at boot time. In this example, no more than 4 ccds may be configured. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase performance. Since the interleave factor is expressed in units of DEV_BSIZE, one must account for sector sizes other than DEV_BSIZE in order to calculate the correct interleave. The kernel will not allow an interleave factor less than the size of the largest component sector divided by DEV_BSIZE. Note that best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. Also note that the total size of concatenated disk may vary depending on the interleave factor even if the exact same components are concate- nated. And an old on-disk disklabel may be read after interleave factor change. As a result, the disklabel may contain wrong partition geometry and will cause an error when doing I/O near the end of concatenated disk. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. WARNINGS
If just one (or more) of the disks in a non-mirrored ccd fails, the entire file system will be lost. FILES
/dev/{,r}ccd* ccd device special files. SEE ALSO
config(1), MAKEDEV(8), ccdconfig(8), fsck(8), mount(8), newfs(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
March 5, 2004 BSD
All times are GMT -4. The time now is 03:48 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy