Sponsored Content
Operating Systems Linux Red Hat Increasing Performance of Disc Arrays Post 302575650 by FireBIade on Tuesday 22nd of November 2011 09:35:20 AM
Old 11-22-2011
I think the hardware can do 'hot spare', the problems are capacity (I needed as much useable space as possible) and internally I think the hardware sees two individual raid controllers making global hot spare not possible. The drives are enterprise class drives so I don't doubt the quality. It's a balance based on the risk vs the importance of the data, and while downtime would be an inconvinience I could recover rapidly from the backups.
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Disc Copy

Is there a disk copy utiliy for unix systems eg: I need to make a duplicate copy of a netraT1 to a netraT1 Thanks (1 Reply)
Discussion started by: SmartJuniorUnix
1 Replies

2. UNIX for Dummies Questions & Answers

Copy of HP-UX from MO disc

This is my newbi question. I have HP-UX on a MO drive, need to backup that MO in case of damaging the original. Therefor I need a copy on server and be able to put that copy onto a blank MO to recreate a working bootable disc. This what I did. First I tried to make a copy with dd dd... (0 Replies)
Discussion started by: tops
0 Replies

3. HP-UX

New MO disc format under HP Unix

How to format new MO disc under HP Unix? (1 Reply)
Discussion started by: vlad3131
1 Replies

4. UNIX for Dummies Questions & Answers

Disc Needs Maintenance

Hello All Here I am using Sun V880 server which have discsuit pack of 8 discs with 2 sub mirrors each. Everything was fine for the last 1 year. Now I am getting problem of taking backup of the server. After analysis what I got that each 2nd submirrors are in NEEDS MAINTENANCE status. What... (5 Replies)
Discussion started by: ailnilanjan
5 Replies

5. News, Links, Events and Announcements

Announcing collectl - new performance linux performance monitor

About 4 years ago I wrote this tool inspired by Rob Urban's collect tool for DEC's Tru64 Unix. What makes this tool as different as collect was in its day is its ability to run at a low overhead and collect tons of stuff. I've expanded the general concept and even include data not available in... (0 Replies)
Discussion started by: MarkSeger
0 Replies

6. UNIX for Dummies Questions & Answers

format disc

What is the best way to format the partition? (3 Replies)
Discussion started by: mirusnet
3 Replies

7. Solaris

Ultra 10 - Copying Files From Disc After Booting Up With Recovery Disc?

Hello, I'm still learning unix and I have what is probably a simple question but I can't seem to find the question to. I have an Ultra 10 Sparc Server running solaris 8 and the drive may have crashed (I hope not). Currently, it appears some files in the /etc folder are missing. I have a backup... (1 Reply)
Discussion started by: ideffects
1 Replies

8. Web Development

PHP arrays in arrays

PHP question... I have an SQL query that's pulled back user IDs as a set of columns. Rather than IDs, I want to use their names. So I have an array of columns $col with values 1,7,3,12 etc and I've got an array $person with values "Fred", "Bert", "Tom" etc So what I want to do is display the... (3 Replies)
Discussion started by: JerryHone
3 Replies

9. Programming

question about int arrays and file pointer arrays

if i declare both but don't input any variables what values will the int array and file pointer array have on default, and if i want to reset any of the elements of both arrays to default, should i just set it to 0 or NULL or what? (1 Reply)
Discussion started by: omega666
1 Replies
volwatch(8)						      System Manager's Manual						       volwatch(8)

NAME
volwatch - Monitors the Logical Storage Manager (LSM) for failure events and performs hot sparing SYNOPSIS
/usr/sbin/volwatch [-m] [-s] [-o] [mail-addresses...] OPTIONS
Runs volwatch with the mail notification support to notify root (by default) or other specified users when a failure occurs. This option is started by default. Runs volwatch with hot spare support. Specifies an argument to pass directly to volrecover if it is running and hot spare support is enabled. DESCRIPTION
The volwatch command monitors LSM waiting for exception events to occur. When an exception event occurs, the volwatch command uses mailx(1) to send mail to: The root account. The user accounts specified when you use the rcmgr command to set the VOLWATCH_USERS variable in the /etc/rc.config.common file. The user account that you specify on the command line with the volwatch command. The volwatch command uses the volnotify command to wait for events to occur. When an event occurs, there is a 15 second delay before the failure is analyzed and the message is sent. This delay allows a group of related events to be collected and reported in a single mail message. By default, the volwatch command automatically starts when the system boots. You can enter the volwatch -s command to start the volwatch command with hot-spare support. Hot-spare support: Detects LSM events result- ing from the failure of a disk, plex, or RAID5 subdisk. Sends mail to the root account (and other specified accounts) with notification about the failure and identifies the affected LSM objects. Determines which subdisks to relocate, finds space for those subdisks in the disk group, relocates the subdisks, and notifies the root account (and other specified accounts) of these actions and their success or failure. When a partial disk failure occurs (that is, a failure affecting only some subdisks on a disk), redundant data on the failed portion of the disk is relocated and the existing volumes comprised of the unaffected portions of the disk remain accessible. Note Hot-sparing is only performed for redundant (mirrored or RAID5) subdisks on a failed disk. Non-redundant subdisks on a failed disk are not relocated, but you are notified of the failure. Only one volwatch daemon can be running on a system or cluster node at any time. Hot-sparing does not guarantee the same layout of data or the same performance after relocation. You may want to make some configuration changes after hot-sparing occurs. Mail Notification Support The following is a sample mail notification when a failure is detected: Failures have been detected by the Logical Storage Manager: failed disks: medianame ... failed plexes: plexname ... failed log plexes: plexname ... failing disks: medianame ... failed subdisks: subdiskname ... The Logical Storage Manager will attempt to find spare disks, relocate failed subdisks and then recover the data in the failed plexes. The following describes the sections of the mail message: The medianame list under failed disks specifies disks that appear to have com- pletely failed; The medianame list under failing disks indicates a partial disk failure or a disk that is in the process of failing. When a disk has failed completely, the same medianame list appears under both failed disks: and failing disks. The plexname list under failed plexes shows plexes that have been detached due to I/O failures experienced while attempting to do I/O to subdisks they contain. The plex- name list under failed log plexes indicates RAID5 or dirty region log (DRL) plexes that have experienced failures. The subdiskname list specifies subdisks in RAID5 volumes that have been detached due to I/O errors. Enabling Hot-Sparing By default, hot-sparing is disabled. To enable hot-sparing, enter the volwatch command with the -s option, for example: # volwatch -s To use hot-spare support you should configure a disk as a spare, which identifies the disk as an available site for relocating failed sub- disks. Disks that are identified as spares are not used for normal allocations unless you explicitly specify otherwise. This ensures that there is a pool of spare disk space available for relocating failed subdisks and that this disk space is not consumed by normal operations. Spare disk space is the first space used to relocate failed subdisks. However, if no spare disk space is available or if the available spare disk space is not suitable or sufficient, free disk space is used. You must initialize a spare disk and place it in a disk group as a spare before it can be used for replacement purposes. If no disks are designated as spares when a failure occurs, LSM automatically uses any available free disk space in the disk group in which the failure occurs. If there is not enough spare disk space, a combination of spare disk space and free disk space is used. When hot-sparing selects a disk for relocation, it preserves the redundancy characteristics of the LSM object to which the relocated sub- disk belongs. For example, hot-sparing ensures that subdisks from a failed plex are not relocated to a disk containing a mirror of the failed plex. If redundancy cannot be preserved using available spare disks and/or free disk space, hot-sparing does not take place. If relocation is not possible, mail is sent indicating that no action was taken. When hot-sparing takes place, the failed subdisk is removed from the configuration database and LSM takes precautions to ensure that the disk space used by the failed subdisk is not recycled as free disk space. Initializing and Removing Hot-Spare Disks Although hot-sparing does not require you to designate disks as spares, Compaq recommends that you initialize at least one disk as a spare within each disk group; this gives you control over which disks are used for relocation. If no spare disks exist, LSM uses available free disk space within the disk group. When free disk space is used for relocation purposes, it is likely that there may be performance degra- dation after the relocation. Follow these guidelines when choosing a disk to configuring as a spare: The hot-spare feature works best if you specify at least one spare disk in each disk group containing mirrored or RAID5 volumes. If a given disk group spans multiple controllers and has more than one spare disk, set up the spare disks on different controllers (in case one of the controllers fails). For a mirrored volume, the disk group must have at least one disk that does not already contain one of the volume's mirrors. This disk should either be a spare disk with some avail- able space or a regular disk with some free space. For a mirrored and striped volume, the disk group must have at least one disk that does not already contain one of the volume's mirrors or another subdisk in the striped plex. This disk should either be a spare disk with some available space or a regular disk with some free space. For a RAID5 volume, the disk group must have at least one disk that does not already contain the volume's RAID5 plex or one of its log plexes. This disk should either be a spare disk with some available space or a regular disk with some free space. If a mirrored volume has a DRL log subdisk as part of its data plex (for example, volprint does not list the plex length as LOGONLY), that plex cannot be relocated. Therefore, place log subdisks in plexes that contain no data (log plexes). By default, the volassist command creates log plexes. For mirroring the root disk, the rootdg disk group should contain an empty spare disk that satisfies the restrictions Although it is possible to build LSM objects on spare disks, it is preferable to use spare disks for hot-spare only. When relocating subdisks off a failed disk, LSM attempts to use a spare disk large enough to hold all data from the failed disk. To initialize a disk as a spare that has no associated subdisks, use the voldiskadd command and enter y at the following prompt: Add disk as a spare disk for newdg? [y,n,q,?] (default: n) y To initialize an existing LSM disk as a spare disk, enter: # voledit set spare=on medianame For example, to initialize a disk called test03 as a spare disk, enter: # voledit set spare=on test03 To remove a disk as a spare, enter: # voledit set spare=off medianame For example, to make a disk called test03 available for normal use, enter: # voledit set spare=off test03 Replacement Procedure In the event of a disk failure, mail is sent, and if volwatch was configured to run with hot sparing support with the -s option, volwatch attempts to relocate any subdisks that appear to have failed. This involves finding appropriate spare disk or free disk space in the same disk group as the failed subdisk. To determine which disk from among the eligible spare disks to use, volwatch tries to use the disk that is closest to the failed disk. The value of closeness depends on the controller, target, and disk number of the failed disk. For example, a disk on the same controller as the failed disk is closer than a disk on a different controller; a disk under the same target as the failed disk is closer than one under a different target. If no spare or free disk space is found, the following mail message is sent explaining the disposition of volumes on the failed disk: Relocation was not successful for subdisks on disk dm_name in volume v_name in disk group dg_name. No replacement was made and the disk is still unusable. The following volumes have storage on medianame: volumename ... These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If non-RAID5 volumes are made unusable due to the failure of the disk, the following is included in the mail message: The following volumes: volumename ... have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. These volumes must have their data restored. If RAID5 volumes are made unavailable due to the disk failure, the following message is included in the mail message: The following RAID-5 volumes: volumename ... have storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. These RAID-5 volumes must have their data restored. If spare disk space is found, LSM attemps to set up a subdisk on the spare disk and use it to replace the failed subdisk. If this is suc- cessful, the volrecover command runs in the background to recover the contents of data in volumes on the failed disk. If the relocation fails, the following mail message is sent: Relocation was not successful for subdisks on disk dm_name in volume v_name in disk group dg_name. No replacement was made and the disk is still unusable. error message If any volumes (RAID5 or otherwise) are rendered unusable due to the failure, the following is included in the mail message: The following volumes: volumename ... have data on dm_name but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. These volumes must have their data restored. If the relocation procedure completes successfully and recovery is under way, the following mail message is sent: Volume v_name Subdisk sd_name relocated to newsd_name, but not yet recovered. Once recovery has completed, a message is sent relaying the outcome of the recovery procedure. If the recovery was successful, the follow- ing is included in the mail message: Recovery complete for volume v_name in disk group dg_name. If the recovery was not successful, the following is included in the mail message: Failure recovering v_name in disk group dg_name. SEE ALSO
mailx(1), rcmgr(8), voldiskadm(8), voledit(8), volintro(8), volrecover(8) volwatch(8)