Sponsored Content
Operating Systems AIX How to set 4 SEA on single VIOS Post 302572978 by gito on Saturday 12th of November 2011 04:49:02 AM
Old 11-12-2011
You can also use vlan taging to multiple vlans over on sea
Code:
Abstract:The use of Virtual  Switches can provide an important new design choice when implementing 
a  Power Server over the originally supported method of Shared Ethernet  Adapter Failover in conjunction
 with the use of VLAN tagging . This  white paper describes the concepts and business value of Virtual  Switches
and also provides detailed instruction for configuration and  implementation.

IBM Techdocs White Paper: Using Virtual Switches in PowerVM to Drive Maximum Value of 10 Gb Ethernet
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Call single function multiple times diff set of parameters

Okay, not sure if it can be done, I would think it could be done and I'm just having a hard time with it. fun_close_wait(){ ipVar="${1} ${2}" portVar=`cat "${5}" | cut -d' ' -f 1` for ip in $ipVar do for port in $portVar do netstatVar=`netstat -n | grep... (4 Replies)
Discussion started by: cbo0485
4 Replies

2. AIX

VIOS SEA on LHEA doesn't work

I am trying to create a SEA on a LHEA port and it gives me error lsdev -Cc adapter: ent0 logical host ethernet port (l-hea) ent1 virtual I/O ethernet adapter mkvdev -sea ent0 -vadapter ent1 -default ent1 -defaultid 199 method error (/usr/lib/methods/cfgsea): Failed to configure SEA... (0 Replies)
Discussion started by: filosophizer
0 Replies

3. AIX

VIOS SEA Creation

Hi Guys, I'm getting the below error while trying to create a SEA adapter in VIOS $ mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1 ... (4 Replies)
Discussion started by: kkeng808
4 Replies

4. AIX

SEA

Hi all, I set up the following configuration on my system: - An LPar with a virtual adapter, first one with a vlan id=703 and id port=13. - The first adapter have to connect to a VIOS in which i configured an SEA. So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Discussion started by: idro
0 Replies

5. Linux

Set password in single command

Hi, Can we set password for linux in non-interactive mode. I didn't find suitable option for this in man page. If we wnter "passwd" command, it will tell "Enter password" and "Re-enter password". i wanted to run this step in a script, and i don't want to use "expect" so i am looking for a single... (8 Replies)
Discussion started by: successlin
8 Replies

6. AIX

Configure VIOS SEA w. load sharing

I am trying to install a VIOS pair with a load-sharing SEA adapter, following this recipe from Developerworks. Without load-sharing everything went fine and worked as expected, but somehow i am a bit lost and the first tries with "ha_mode=sharing" didn't work at all. Here is the situation: I... (6 Replies)
Discussion started by: bakunin
6 Replies

7. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

8. AIX

SEA configuration

i want configure a SEA over my vios , i have a message error : Method error (/usr/lib/methods/cfgsea): Failed to configure SEA with return code 1 and SEA-specific error code 10: Detailed info: Setting real adapter ent1 in promiscuous mode failed... (5 Replies)
Discussion started by: hedou
5 Replies

9. AIX

SEA to standby

hello, what will happen if i try to move sea of my 1 vio server to standby( using chdev command), when sea of other vio server is already in standby mode? (1 Reply)
Discussion started by: amvineeth
1 Replies

10. AIX

VIOS entstat versus seastat for SEA

Hello, I found that the packet counts given by entstat -d SEA is not the same as the total of the packet counts given by seastat -d SEA for the same interval of time. Do anyone have an explanation for the difference. We recently got a recommendation that the throughput on an SEA should not... (5 Replies)
Discussion started by: N8R
5 Replies
scconf_transp_adap_ce(1M)				  System Administration Commands				 scconf_transp_adap_ce(1M)

NAME
scconf_transp_adap_ce - configure the ce Sun Ethernet transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure ce adapters as cluster transport adapters. These adapters can be used with transport types dlpi. The ce adapter is VLAN capable. A ce adapter connects to a transport switch or to another ce adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ce(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ce(1M)