09-14-2011
Identify Boot from SAN
Hi, I have many servers all of these are boot from SAN. Can anybody let me know that how to identify the server is Boot fron SAN and from which device?
Thanks
Rahul
10 More Discussions You Might Find Interesting
1. HP-UX
Hi all,
I am trying to configure my HPUX host 11.31 IA64 to boot from a LUN for EMC clariion CX3-80 (Flaire PNR 26).
I am following the below mentioned steps..
vi /tmp/idf
3
EFI 500MB
HPUX 100%
HPSP 400MB
idisk -f /tmp/idf -w /dev/rdisk/diskxxx
insf -e
pvcreate -B... (0 Replies)
Discussion started by: barun agarwal
0 Replies
2. Red Hat
hi all,
i have qle 2460 hba card in my server. and i have a lun from promise array from raid 0. I want to boot my OS (rhel5.2-64 bit) lun on a dell t300 server. can some one help me on this please asap.. (0 Replies)
Discussion started by: navadeep
0 Replies
3. Solaris
My current situation is like this, I have a v440 connected to a netapp central storage 3140 via fiber channel, my OS and oracle is installed in the internal drive of the v440.
What I would like to do is to advertise another LUN in netapp to the v440 and let my v440 boot from it so I can start... (3 Replies)
Discussion started by: q8devilish
3 Replies
4. UNIX for Advanced & Expert Users
Hi There,
Has anyone had any luck with or know how to get AIX 5+ to boot from a HP EVA 6000 SAN?
The servers used here will be P Class Blades
My initial searches on this so far did not bring results so I am guessing this may not be possible on HP SAN's but please let me know if I am... (0 Replies)
Discussion started by: fazzasx
0 Replies
5. UNIX for Dummies Questions & Answers
Hello everybody,
I'm using the binary inqraid (Linux RHEL) in order to retrieve information about SAN disks. The questions are:
Given an LDEV, how do I know if the SAN disk related to this LDEV is being used by the OS? I mean, how can I demonstrate to "Storage department" that all disks of... (4 Replies)
Discussion started by: asanchez
4 Replies
6. Red Hat
Hello,
How can I identify SAN disks not in use by the OS?
Thank you. (8 Replies)
Discussion started by: asanchez
8 Replies
7. Solaris
I have a solaris 10 box which does not have internal disks it has just a single dual port HBA card. Storage team has assigned 2 LUNs to the system and i can see it from the probe-scsi-all
/pci@3,700000/SUNW,emlxs@0,1
Device PortID 10100 WWPN 5006016941e0a08d
LUN 0 Disk DGC ... (0 Replies)
Discussion started by: fugitive
0 Replies
8. Solaris
How to identify the server is BOOT FROM SAN.
Also how one can find from which device it is booted?
Thanks
Rahul
Double post, continued here (0 Replies)
Discussion started by: rahul.kurumkar
0 Replies
9. UNIX for Dummies Questions & Answers
We can Know the storage devices in fdisk -l. But Please tell me how can i identify the SAN devices :wall:
How SAN devices are represented in the fdisk -l output :wall::wall:
Thanks in Advance........:D (3 Replies)
Discussion started by: vamshigvk475
3 Replies
10. Solaris
I am working on VM host and collecting data to identify the type of storage attached to the server which will be migrated to VNX.
it has one ldom created on it
luxadm probe output ---
No Network Array enclosures found in /dev/es
Found Fibre Channel device(s):
Node... (7 Replies)
Discussion started by: kpatel786
7 Replies
fp(7d) Devices fp(7d)
NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)