Quote:
Originally Posted by DGPickett
The man seems to day you can pull them all offline, but is otherwise terse, so maybe they assume if you want to limp without the bad drive, you just pull it? Maybe the facility you want is lower down, in the system device layer not the md virtual device layer.
According to what I've read elsewhere you should be able to.....

mdadm --stop /dev/thatarray

mdadm --fail /dev/thatdrive

and then the drive should no longer show as in the array.....well that's the theory but it ain't working in practice.
 

10 More Discussions You Might Find Interesting

1. Solaris

Resyncing Progress of hardware mirror

Hi, I've recently mirrored the 4 disks in a V440. Disks 0 + 1 have been mirrored with hardware mirroring using the command raidctl -c c1t0d0 c1t2d0, the other 2 disks have been mirrored using Soltisce Disk Suite. I know how to check the progress for the SDS mirroring but how can I find the... (2 Replies)
Discussion started by: Chains
2 Replies

2. Solaris

Unable to mount USB Pen drive on my Server

Hello Gurus!! Very recently i tried to mount a USB pen drive onto my solaris 10 (X4170 model) server. As i understand, in ideal scenarios it should get mounted automatically, but it did not happen. Neither anything is shown in "iostat -En" output or "rmformat -l" about the pen drive. I also... (10 Replies)
Discussion started by: EmbedUX
10 Replies

3. UNIX for Advanced & Expert Users

mdadm question

Hello, I have 4 drives (500G each) in a raid 10, I got a power failior and this is the result? cat /proc/mdstat Personalities : md126 : inactive sdb sdc sdd sde 1953536528 blocks super external:-md127/0 md127 : inactive sdd(S) sde(S) sdb(S) sdc(S) 9028 blocks super... (3 Replies)
Discussion started by: rmokros
3 Replies

4. UNIX for Advanced & Expert Users

mdadm container! How does it work

Hi everyone, I am not sure if I understand how mdadm --create /dev/md0 --level=container works? A device called /dev/md0 appears in /proc/mdstat but I am not sure how to use that device? I have 2 blank drives with 1 500GB partition on each. I would like to setup mirroring, but not in the... (0 Replies)
Discussion started by: hytron
0 Replies

5. Debian

Unable to mount external drive

Trying to mount an external 160GB Toshiba drive but.... this is my dmesg tail output: usb 2-2: new high speed USB device using ehci_hcd and address 3 usb 2-2: New USB device found, idVendor=13fd, idProduct=1618 usb 2-2: New USB device strings: Mfr=0, Product=0, SerialNumber=0 usb 2-2:... (4 Replies)
Discussion started by: Ridson
4 Replies

6. Red Hat

mdadm for / and /boot

had this RHEL 5 installation with /dev/sda1 and /dev/sda2 running.. created two more partitions /dev/sdj1 and /dev/sdj2 , the same sized partition as /dev/sda trying to use mdadm to create RAID1 .. I cannot even do it in "rescue" mode, I wonder if it can be done.. it kept... (2 Replies)
Discussion started by: ppchu99
2 Replies

7. UNIX for Dummies Questions & Answers

unable to automount a cifs drive in linux

Hi I am using SUSE 11 linux I have couple of "nfs" entries in /etc/fstab which are automatically loaded after system restart. One of the entry is windows drive mounted using cifs as shown below //IP-Address/Partition /mnt/x cifs credentials=/creds/.creds,rw,uid=<name> 0 0 I want to... (1 Reply)
Discussion started by: rakeshkumar
1 Replies

8. Filesystems, Disks and Memory

MDADM Failure - where it came from?

Hello, i have a system with 6 sata3 seagate st3000dm01 disks running on stable Debian with software raid mdadm. i have md0 for root and md1 for swap and md2 for the files. i now want to add one more disk = sdh4 for md2 but i got this errors: The new disk is connected to an 4 port sata... (7 Replies)
Discussion started by: Sunghost
7 Replies

9. Solaris

Unable to send SCSI commands to USB Drive

I am connecting a USB mass storage removeable drive to Solaris 10 x86 machine. The device is detected and i am able to perform standard read and write functions. But i want to use a code to send IOCTL based SCSI commands to the same device to read and write the data. Which i am unable to do so.... (17 Replies)
Discussion started by: danish2012
17 Replies

10. Solaris

Maint, resyncing and last-erred notifications

Hi fellow members! I have a oracle solaris server with two internal disks, that acts as an authentication server only, and for now the server seems to be doing its job, but when typing metastat -c I get some notifications. I am not familiar with SVM, I wonder if someone can help me on this:... (3 Replies)
Discussion started by: fretagi
3 Replies
saconfig(1M)															      saconfig(1M)

NAME
saconfig - Command Line Configuration Utility for the HP SmartArray RAID Controller Family SYNOPSIS
<device_file> <device_file> -N <device_file> -R <RAID_level> [-S <stripe_size>] -p <physical_drive_id> [-p <physical_drive_id> ...] [-s <physical_drive_id>] [-c <capac- ity>] <device_file> -e <low|medium|high> <device_file> -r <low|medium|high> <device_file> -P <default|shortest|longest> <device_file> -A <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s all <device_file> -D <logical_drive_num> <device_file> -D all <device_file> -C <read_caching_percentage> <device_file> -F on <device_file> -F off <device_file> -I -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -I -l <logical_drive_num> <device_file> -E <logical_drive_num> -c <capacity> <device_file> -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] <device_file> -M <logical_drive_num> -S <stripe_size> DESCRIPTION
The command is a command line configuration tool for the HP SmartArray RAID Controller Family. This command provides the ability to create a logical drive, add a spare drive to existing logical drive, display configuration, delete a logical drive, and clear configuration. This command also enables the cache when it is used to create the first logical drive on the SmartArray RAID Controller. Furthermore it allows the option of changing the percentage of total cache size used for read caching and write caching. The auto-fail missing disks at boot fea- ture can be enabled or disabled using this command. Prerequisites needs to be able to create the /tmp/saconfig.lock file when it starts executing. This prevents multiple users from running This lock file is removed when exits. Security Restrictions requires either the superuser privilege or and privileges. See privileges(5) for more information about privileged access on systems that support fine-grained privileges. Options recognizes the following options and parameters as indicated in the SYNOPSIS section above. <device_file> To specify the device file for the SmartArray RAID Controller. The device file is as displayed by the command for the appropriate SmartArray RAID Controller. With no other options, displays size and status for all physical drives and RAID level, size, and status for all logical drives. With the option saconfig displays size and status for all physical drives and RAID level, size, and status for all logical drives. But the persistent device files (see intro(7)) will be displayed as against legacy device files in the absence of this option. -R <RAID_level> To create a logical drive with the specified RAID level. The supported RAID levels are 0, 1, 1+0, 5, and ADG. The lowest logical drive number not already in use will be given to the newly created logical drive, starting from 0. To determine the hardware path and device file for the logical drive, use the command. The logical drives are dis- played in the same order as in the output. RAID 1+0 logical drive requires even number of physical drives (minimum of 2). To achieve optimal fault tolerance, it is best to specify the same number of physical drives per channel if possible when creating a RAID 1+0 logical drive. This ensures the physical drives in each mirrored pairs would be on different channels. -S <stripe_size> To specify the stripe size for the logical drive to be created. The supported stripe sizes are 8, 16, 32, 64, 128, and 256 (KB). 128 and 256 stripe sizes are not available for RAID 5 or ADG logical drive. If this option is not used to specify the stripe size, default stripe size will be used to create the logical drive. For RAID 0 and 1+0 logical drive, the default size is 128. For RAID 5 and ADG logical drive, the default size is 16. -p <physical_drive_id> To specify the SCSI physical disk. It can be represented as <channel_id>:<target_id> (e.g., 4:12). Valid channel numbers are between 1 and 4. Valid target numbers are between 0 and 15. To specify the SAS/SATA physical disk. It can be represented as either <connector>:<enclosure>:<bay> (e.g., 2I:1:10) or <wwid> (e.g., 0x500000e010f16432). -s <physical_drive_id> To specify a spare drive to be included in the logical drive configuration. Refer <physical_drive_id> to -p option. -c <capacity> To specify the size in GB of a logical drive to be created. -A <logical_drive_num> To specify which logical drive to add spare drive to. -e <low | medium | high> To change the expand priority of controller to one of Low, Medium, High. When there are no logical drives, expand priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subse- quent logical drive creation will change the expand priority value of the controller to medium. -r <low | medium | high> To change the rebuild priority of controller to one of Low, Medium, High. When there are no logical drives, rebuild priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subsequent logical drive creation will change the rebuild priority value of the controller to high. -P <default | shortest | longest> To change the path selection method by the controller firmware. If it is set to default, firmware will select the Active path on its own. If the selection method is set to shortest, firmware will select the shortest path as the Active Path. If the path selection method is longest, firmware will select the longest path as the Active Path. All multi path configurations are Active-Standby configurations. -D <logical_drive_num> -s <physical_drive_id> To delete the spare drive from the specified logical drive. -D <logical_drive_num> -s all To delete all of spare drives from the specified logical drive. -D <logical_drive_num> To delete the specified logical drive. -D all To clear configuration. -C <read_caching_percentage> To specify the percentage of total cache size to be used for read caching. The remaining percentage will be used for write caching. Valid read caching percentage numbers are 0, 25, 50, 75, and 100 (%). -F on To enable auto-fail missing disks at boot feature. -F off To disable auto-fail missing disks at boot feature. -I -p <physical_drive_id> [-p <physical_drive_id> ...] To identify SAS/SATA physical drive(s) by LED. -I -l <logical_drive_num> To identify a SAS/SATA logical drive by LED. -E <logical_drive_num> -c <capacity> To extend the capacity of the specified logical drive up to larger capacity. The capacity is in GB. -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] To expand the specified logical drive and others in an array by physical drive(s). -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] To perform RAID level [with stripe size] migration on the specified logical drive. The stripe size is in KB. -M <logical_drive_num> -S <stripe_size> To perform stripe size migration on the specified logical drive. The stripe size is in KB. Logical Drive State Definitions All physical disks in the logical drive are operational. Some possible causes: Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive have failed. One or more disks in a RAID 0 logical drive have failed. Cache data loss has occurred. Array expansion was aborted. The logical drive is temporarily disabled because another logical drive on the controller had a missing disk at power-up. Also known as "degraded" state. A physical disk in a fault tolerant logical drive has failed. For RAID 1, 1+0 or 5, data loss may result if a second disk should fail. For RAID ADG, data loss may result if two additional disks should fail. A replacement disk is present, but rebuild hasn't started yet (another logical drive may be currently rebuilding). The logical drive will also return to this state if the rebuild had been aborted due to unrecoverable read errors from another disk. One or more physical disks in this logical drive are being rebuilt. While the logical drive was in a degraded state, the system was powered off and a disk other than the failed disk was replaced. Shut off the system and replace the correct (failed) disk. While the system was off, one or more disks were removed. Note: the other logical drives are held in a temporary "failed" state when this occurs. The data in the logical drive is being reorganized because: Physical disks have been added to the array (capacity expansion). The stripe size is being changed (stripe-size migration). The RAID level is being changed (RAID-level migration). A capacity expansion operation is in progress (or is queued up) that will make room on the disks for this new logical drive. Until room has been made on the physical disks, this newly configured logical drive cannot be read or written. The logical drive is waiting to undergo data reorganization (see EXPANDING above). Possible causes for the delay are a rebuild or expansion operation may already be in progress. Physical Disk State Definitions The physical disk is configured in one or more logical drives and is operational. The physical disk is configured as a spare disk. The physical disk has not been configured in any logical drives. The configured physical disk has failed. Return Value returns the following values: Successful completion. Command line syntax error. Incompatible CISS driver API. Failure opening a file. Other error. Examples To display configuration on the SmartArray RAID Controller /dev/ciss5 - To create a RAID 1+0 logical drive to include physical drives 4:0 and 4:1 and spare drive 4:2 - -R -p -p -s To create a RAID ADG logical drive with stripe size 64 to include physical drives 1:2, 2:2, 3:2 and 4:2 - -R -S -p -p -p -p To create a RAID 5 logical drive with capacity 45 GB to include SAS physical drives 1I:1:16, 1I:1:15, and 1I:1:14 - -R -c -p -p -p To set the expand priority of logical drives on a controller to medium -e To set the rebuild priority of logical drives on a controller to high -r To add spare drive 1:0 to logical drive 1 - -A -s To delete spare drive 1:0 from logical drive 1 - -D -s To delete all spare drives from logical drive 1 - -D -s To delete logical drive 0 - -D To clear configuration - -D To change read caching percentage to 75% - -C To extend logical drive 2 upto 45 GB in capacity - -E -c To expand logical drive 0 with 2 SAS physical drives - -E -p -p To migrate logical drive 2 with stripe 32 - -M -S To migrate logical drive 2 to RAID level 5 with stripe 64 - -M -R -S AUTHOR
was developed by HP. FILES
Executable file. saconfig lock file. Device files. SEE ALSO
sautil(1M), privileges(5), intro(7). saconfig(1M)
All times are GMT -4. The time now is 04:56 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy