05-27-2011
Sun T3-1 hardware RAID
Hi all
I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS.
The documentation doesn't make it clear if:
1. The drives are hot swappable if the RAID is configured using Fcode
2. How would I know if a drive failed (or is busy failing) if the RAID utility is only accessible from OBP.
Does anyone have any experience configuring RAID on a T3-1 server?
Many thanks
9 More Discussions You Might Find Interesting
1. Solaris
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies
2. Solaris
Hi,
I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1"
The System did come preinstalled as it comes from sun. I did not do much on it.
I booted system using boot cdrom -s
gave format... (6 Replies)
Discussion started by: upengan78
6 Replies
3. Solaris
Hi everyone
I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive.
My question is, how would I know when one of the drives become faulty?
Thanks (2 Replies)
Discussion started by: soliberus
2 Replies
4. UNIX for Dummies Questions & Answers
Hi
Can someone tell me what are the differences between software and hardware raid ?
thx for help. (2 Replies)
Discussion started by: presul
2 Replies
5. Solaris
Hi,
I have a question. Do LiveUpgrade supports hardware raid?
How to choose the configuration of the system disk for Solaris 10 SPARC?
1st Hardware RAID-1 and UFS
2nd Hardware RAID-1 and ZFS
3rd SVM - UFS and RAID1
4th Software RAID-1 and ZFS
I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies
6. Hardware
Hi All
I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command.
Following is the hardware RAID output.
root@oracledatabaseserver / $ raidctl
RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies
7. Solaris
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
Discussion started by: KhawHL
4 Replies
8. Solaris
We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.
We have 2 LDOM configured on this server and this server running on single disk.
#... (8 Replies)
Discussion started by: rock123
8 Replies
9. Solaris
Dear All ,
we have hardware raid 1 implemented on Solaris Disks.
We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers.
Thanks...
Rj (7 Replies)
Discussion started by: jegaraman
7 Replies
LEARN ABOUT NETBSD
arcmsr
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)
NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)
HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD
March 3, 2008 BSD