05-08-2011
Hi DB,
Thanks for the reply.
Yes, now the issue has been fixed. Now the ignite contains vpar software in it which it was missing.
When we created first vpar it worked properly with vpar software being installed lateron.Might be because that npar was holding only one vpar that time and vpar software was installed in at npar level. But for second vpar the SAN disk was unable to boot without vpar software.Now it is up and running fine.
Thanks.
Regards,
Laxmikant
9 More Discussions You Might Find Interesting
1. Solaris
When I installed the SOLARIS 10 OS first time, the desktop would not start up, this was because of network setup. Reinstalled worked. After a week due to some problem I had to reinstall OS, installation went fine and but when i reboot I get this error.
cannot find mis/krtld
boot error loading... (0 Replies)
Discussion started by: johncy_j
0 Replies
2. UNIX for Dummies Questions & Answers
VERY new to Unix here! I have a client with a unix machine(Sun Systems Unix system V Release 4.0) that gets an error on boot up.
"7.e.1": Syntax error in tty mode
Like I said, I new to Unix as this is my first time ever touching a Unix machine. So, I don't know if this is a major or minor... (0 Replies)
Discussion started by: rlpierce04
0 Replies
3. AIX
Hi all,
I have one booting problem with an AIX machine. It is not booting.
It is showing error B1014602 on OK prompt.
Could you please tell me, what is the problem with it and its respective solution?
Thank you very much. (2 Replies)
Discussion started by: prashantchavan
2 Replies
4. HP-UX
Hi
Can I use a vpar as an ignite server? (1 Reply)
Discussion started by: mahlathini
1 Replies
5. HP-UX
I wonder if anyone could assist with this.
We have taken over administration of an rp8440 that has been split into 2 nPars and has 4vPars per nPar.
I have to add a network card into one of the vPars that was missed at the time the vPar was created. That bit i have no problem with.
The... (0 Replies)
Discussion started by: Andyp2704
0 Replies
6. SCO
hi
SCO Unix 5.0.6 doesn't boot due to this problem:
not a directory
boot not found
cannot open
stage 1 boot failure: error loading hd (40)/boot
Knows someone howto solve it? (16 Replies)
Discussion started by: ccc
16 Replies
7. HP-UX
Hi guys,
I'm moving some vPars from BL860c I2 and BL870c I2 using the DRD clone and relocation. In some case, as instance to upgrade to BL870c I2, the ERRATA document reports some additional driver to be added to the image made by the DRD and then recompile the kernel before the move to the... (0 Replies)
Discussion started by: cecco16
0 Replies
8. HP-UX
Hello Guys
Could you please let me know the command to find the resource (vCPU & Memory) capacity limit for the VPAR's (HPUX 11.23) on integrity Virtual host servers running HPUX 11.31 OS.
For eg. I want to know what is the max vCPU and memory that I can assign to one VPAR.
The Base Virtual... (0 Replies)
Discussion started by: prvnrk
0 Replies
9. HP-UX
Hi,
How can I shutdown a vpar from another vpar ? Please provide the command. Thanks. (0 Replies)
Discussion started by: snchaudhari2
0 Replies
LEARN ABOUT HPUX
vparremove
vparremove(1M) vparremove(1M)
NAME
vparremove - remove a virtual partition
SYNOPSIS
vp_name db_file]
DESCRIPTION
The command deletes a virtual partition previously created using the command. All resources associated with the virtual partition are made
available for allocation to other partitions.
Unintentional use of this command has serious consequences; therefore the user is prompted to confirm the operation unless the (force)
option is specified.
Options
recognizes the following command line options and arguments:
Specifies the unique name of the virtual partition which
is to be removed. Required.
Removes a virtual partition from the partition database
contained in db_file. If this option is omitted, the virtual partition is removed from the monitor's database. In this
case, the partition must be in the state to be removed. Thus it is an error to try to remove the current virtual partition,
the one in which the command is executing.
Specifies the force option.
Omits the confirmation dialog before removing the virtual partition. This option is intended for use by scripts and other
non-interactive applications.
SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser.
When virtual partition flexible administrative capability is enabled, a virtual partition can only be removed from within a Designated-
Admin vPar.
RETURN VALUE
The command exits with one of the following values:
Successful completion.
One or more error conditions occurred.
EXAMPLES
Destroy the virtual partition in the partition database currently running in the monitor:
Destroy the virtual partition in the partition database currently running in the monitor using the force option:
Delete partition in partition database file
ERRORS
displays error messages on standard error for any of the following conditions:
o db_file does not exist, cannot be accessed, is not a virtual partition database file, or is corrupt.
o vp_name does not exist in the monitor's database or in db_file.
o vp_name in the monitor's database is in some state other than
o The command and the virtual partition monitor are at different revision levels.
o When the virtual partition flexible administrative capability is enabled and the local virtual partition is not a Designated-
Admin vPar.
AUTHOR
was developed by the Hewlett-Packard Company.
SEE ALSO
vparadmin(1M), vparboot(1M), vparconfig(1M), vparcreate(1M), vpardump(1M), vparefiutil(1M), vparenv(1M), vparextract(1M), vparmodify(1M),
vparreloc(1M), vparreset(1M), vparstatus(1M), vparutil(1M), vparresources(5), vpartition(5), vpmon(5).
vparremove(1M)