Sponsored Content
Operating Systems Solaris Sun v440 Drive in Slot 1 not listed but its active Post 302516211 by ningy on Friday 22nd of April 2011 03:01:26 AM
Old 04-22-2011
V440 has hardware raid enabled by default ( raidctl will give an idea abt this ).
Check out system specs for more details.
 

9 More Discussions You Might Find Interesting

1. Solaris

Sun v440/v880 network adapter teaming

Is it possible to team two network adapters for fault tolerance in a Sun v440 or v880 Solaris 8 box? If so how would I go about doing so? (1 Reply)
Discussion started by: ghuber
1 Replies

2. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

3. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. Solaris

SUN V440 Question

I have a SUN V440 and it is running Solaris 9 with two NICs in the box ce0 ce1. Is there any way to get full duplex 1000? I do I check to see what ce0 and ce1 is set at and if it is not set to full duplex 1000, how do I set it and do I have to reboot the system afterward? I am new to the SUN unix... (5 Replies)
Discussion started by: pmwayne01
5 Replies

7. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

8. Solaris

SAS drive USB caddy on Solaris V440

Got a T2000 which has got the 2.5" SAS drives. Want to be able, if I can, to connect to USB caddy and connect to a V440. Anyone ever tried this? To be honest, having problems even finding a SAS-USB caddy. (0 Replies)
Discussion started by: psychocandy
0 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies
IDA(4)							   BSD Kernel Interfaces Manual 						    IDA(4)

NAME
ida -- Compaq Intelligent Drive Array Controllers SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device scbus device ida Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): ida_load="YES" DESCRIPTION
The Compaq Intelligent Drive Array (IDA) technology is used to distribute data across an array of hard drives. It unites these hard drives into one or more high-performance logical drives. The drive array is managed by an array controller. These controllers have the ability to provide fault tolerance for the connected drives and optionally provide write cache for the logical drives. It is also possible for an application to access the SCSI bus subsystem directly by using the pass-through interface. HARDWARE
The following controllers are supported by the ida driver: o Compaq SMART Array 221 o Compaq Integrated SMART Array Controller o Compaq SMART Array 4200 o Compaq SMART Array 4250ES o Compaq SMART 3200 Controller o Compaq SMART 3100ES Controller o Compaq SMART-2/DH Controller o Compaq SMART-2/SL Controller o Compaq SMART-2/P Controller o Compaq SMART-2/E Controller o Compaq SMART Controller IMPLEMENTATION NOTES
Extreme caution should be exercised when using the pass-through interface. It is possible to interfere with normal system I/O and cause hangs if pass-through is used to an active device. Pass-through should only be used to a device that is otherwise quiescent. SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8) AUTHORS
The ida driver was written by Jonathan Lemon <jlemon@FreeBSD.org> and Matthew N. Dodd <mdodd@FreeBSD.org>. This manual page was written by Tom Rhodes <trhodes@FreeBSD.org>. BSD
August 8, 2004 BSD
All times are GMT -4. The time now is 03:18 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.