Sponsored Content
Operating Systems Solaris Adding new hard drives on Sun SPARC T5440 server with Solaris 10 Post 302511043 by sodamncool on Tuesday 5th of April 2011 03:46:27 PM
Old 04-05-2011
use

newfs /dev/rdsk/c0t2d0sx

where x = 0 or 1 or 2 or 3 or 4 or 5 or 6

you need to run format. select the new disk. setup the slice sizes and then run newfs against the slice(s) that you have created.
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Info Needed in Seting up An apache Web Server on A Sun Sparc with Solaris 8

I need help in the form of the complete procedures necessary in setting up an Apache web server on a Sun Sparc running Solaris 8 David Johnston P.S New to the Unix arena (1 Reply)
Discussion started by: David Johnston
1 Replies

2. Solaris

Add new hard disk to sun sparc server?

A sparc server has a new SCSI hard disk added and labeled by the engineer, but they need to be formatted identically to an existing disk (c4t0d0). You decide to script the process and run from the command line without interaction. I know that the following command line must be achieve this. #... (3 Replies)
Discussion started by: kingsan
3 Replies

3. Solaris

Sun Solaris 9 E250 -- Suggestions For External Hard Drives

Hello, Running a Sun Solaris 9 E250 and need advice or suggestions on what type of external hard disks are compatible and or available. It's an old machine and is due for replacement soon but in the short term need an external hard drive for backup etc as the partner/backup machine has just... (2 Replies)
Discussion started by: KenLynch
2 Replies

4. Filesystems, Disks and Memory

Help adding new hard drives

Folks; I just added 2 physical new hard drives to my SUSE server. My server is already running SUSE 10.3 version. Is there a command i can use to add the new space or even see if the system can sees them? (3 Replies)
Discussion started by: Katkota
3 Replies

5. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies

6. Solaris

Unplug power from Sparc Server T5440 when in OpenBoot

show /HOST command shows that status = OpenBoot Running when in this state, can the power be unplugged from the server ? we are unable to bring the status to "powered off". Even if we issue "stop /SYS" it will momentarily be in the powered off status and then go back to power on... (1 Reply)
Discussion started by: paulk93
1 Replies

7. Solaris

SPARC Enterprise T5440 Server, can not power off

SPARC Enterprise T5440 Server, can not power off I connect to Service Processor via serial port and submit the following to boot the system, it boots fine but can not power off the system. Can someone help? The following takes me to unix login -> start /SYS -> start /SP/console... (6 Replies)
Discussion started by: paulk93
6 Replies

8. Solaris

Solaris 8 - Accessing Hard Drives

Hi, I have two SCSI Hard Drives in a Sun Solaris 8 server as shown below. I would like to access Disk1 and look at its contents, directory structure and files. How do I change my default directory from Disk 0 to Disk 1 and vice versa? Thank you. (5 Replies)
Discussion started by: ssabet
5 Replies
MLXCTL(8)						    BSD System Manager's Manual 						 MLXCTL(8)

NAME
mlxctl -- Mylex DAC960 family management utility SYNOPSIS
mlxctl [-f dev] [-v] [-a] status [drive] [...] mlxctl [-f dev] [-a] detach [drive] [...] mlxctl [-f dev] [-a] check [drive] [...] mlxctl [-f dev] rebuild channel:target mlxctl [-f dev] cstatus mlxctl [-f dev] rescan mlxctl [-f dev] config DESCRIPTION
The mlxctl utility performs status monitoring and management functions for Mylex DAC960 RAID controllers and attached devices. The following options are available: -a Apply the action to all drives attached to the controller. -f dev Specify the control device to use. The default is /dev/mlx0. -v Increased verbosity. The following commands are available: cstatus Display the controller's current status. status Display the status of the specified drives. This command returns 0 if all drives tested are online, 1 if one or more drives are critical and 2 if one or more are offline. rescan Re-scan the logical drive table, and attach or detach devices from the system as necessary. detach Detach the specified drives. Drives must be unmounted and unopened for this command to succeed. check Initiate a consistency check and repair pass on a drive that provides redundancy (e.g., RAID1 or RAID5). This command returns imme- diately. The status command can be used to monitor the progress of the check. rebuild Rebuild onto the specified physical drive. Note that there can be only one running rebuild operation per controller at any given time. This command returns immediately. The cstatus command can be used to monitor the progress of the rebuild. config Write the current system drive configuration to stdout. EXAMPLES
Display the status of drive ld3 attached to the controller mlx1: mlxctl -f /dev/mlx1 -v status ld3 SEE ALSO
ld(4), mlx(4) HISTORY
The mlxctl command first appeared in NetBSD 1.5.3, and was based on the mlxcontrol utility found in FreeBSD. BUGS
Modifying drive configuration is not yet supported. Some commands do not work with older firmware revisions. Error log extraction is not yet supported. BSD
April 10, 2000 BSD
All times are GMT -4. The time now is 09:24 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy