Sponsored Content
Full Discussion: fmadm faulty output
Operating Systems Solaris fmadm faulty output Post 302489594 by garskoci on Thursday 20th of January 2011 08:47:53 PM
Old 01-20-2011
royalliege - entries in fault manager have to be cleared out manually. They will remain until they are cleared. If you look at the output, you will see a date of when the error occurred. I don't know your system, but that error could be from years ago. Even though the initial problem has been resolved, the error will need to be cleared. For example, if you have a failed DIMM and you see it listed in the fault manager, you will still need to clear the message after the DIMM is replaced.
This User Gave Thanks to garskoci For This Post:
 

10 More Discussions You Might Find Interesting

1. Solaris

Faulty PSU - but its still working !?!

Hello We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error... (8 Replies)
Discussion started by: hcclnoodles
8 Replies

2. Solaris

Replacing a faulty volume

Hi All, I replace a sub-mirror of a mirrored volume by using below command: #metadetach d10(mirror) d11(striped) #metattach d10 d13(other striped) With above process I successfully replaced a faulty volume. I want to knoow if the process I followed is right. Or if not, what... (5 Replies)
Discussion started by: naw_deepak
5 Replies

3. Solaris

fmadm on an M4000

Hi people, Hoping someone has maybe done this before? I'm trying to run fmadm from the xcsf prompt on an M4000 and it won't run, complaining about insufficient privileges, even though the user has supposedly been setup with fieldeng privileges. Anyone got any ideas? Cheers Rgrds... (10 Replies)
Discussion started by: callmebob
10 Replies

4. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

5. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

8. Red Hat

HBA card faulty

Hi, How to determine if HBA card in getting faulty from linux host ? any pointers. (2 Replies)
Discussion started by: saurabh84g
2 Replies

9. Hardware

Faulty parts in a frame

Hello, Following parts need to be replaced in a frame as suggested by IBM 1. Flexible Cable 2. Service Processor Card Would these faulty parts impact all lpars which are there in this frame? Best regards, Vishal (5 Replies)
Discussion started by: admin_db
5 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
fmd(1M) 						  System Administration Commands						   fmd(1M)

NAME
fmd - fault manager daemon SYNOPSIS
/usr/lib/fm/fmd/fmd [-V] [-f file] [-o opt=val] [-R dir] DESCRIPTION
fmd is a daemon that runs in the background on each Solaris system. fmd receives telemetry information relating to problems detected by the system software, diagnoses these problems, and initiates proactive self-healing activities such as disabling faulty components. When appropriate, the fault manager also sends a message to the syslogd(1M) service to notify an administrator that a problem has been detected. The message directs administrators to a knowledge article on Sun's web site, http://www.sun.com/msg/, which explains more about the problem impact and appropriate responses. Each problem diagnosed by the fault manager is assigned a Universal Unique Identifier (UUID). The UUID uniquely identifes this particular problem across any set of systems. The fmdump(1M) utility can be used to view the list of problems diagnosed by the fault manager, along with their UUIDs and knowledge article message identifiers. The fmadm(1M) utility can be used to view the resources on the system believed to be faulty. The fmstat(1M) utility can be used to report statistics kept by the fault manager. The fault manager is started automatically when Solaris boots, so it is not necessary to use the fmd command directly. Sun's web site explains more about what capabilities are cur- rently available for the fault manager on Solaris. OPTIONS
The following options are supported -f file Read the specified configuration file prior to searching for any of the default fault manager configuration files. -o opt=value Set the specified fault manager option to the specified value. Fault manager options are currently a Private inter- face; see attributes(5) for information about Private interfaces. -R dir Use the specified root directory for all pathnames evaluated by the fault manager, instead of the default root (/). -V Print the fault manager's version to stdout and exit. EXIT STATUS
The following exit values are returned: 0 Successful completion 1 An error occurred which prevented the fault manager from initializing, such as failure to open the telemetry trans- port. 2 Invalid command-line options were specified. FILES
/etc/fm/fmd Fault manager configuration directory /usr/lib/fm/fmd Fault manager library directory /var/fm/fmd Fault manager log directory ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWfmd | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
svcs(1), fmadm(1M), fmdump(1M), fmstat(1M), syslogd(1M), attributes(5), smf(5) http://www.sun.com/msg/ NOTES
The Fault Manager is managed by the service management facility, smf(5), under the service identifier: svc:/system/fmd:default The service's status can be queried using the svcs(1) command. Administrators should not disable the Fault Manager service. SunOS 5.10 17 Nov 2004 fmd(1M)
All times are GMT -4. The time now is 11:32 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy