11-03-2010
Quote:
Originally Posted by
verdepollo
What about a way to fast travel long distances?
You know, instead of driving to the office, or walking 1/2 mile to a restaurant or spending a whole day at the airport if you want to travel to the other side of the globe, it would be nice to have "something" that let us travel instantly, or at least faster.
People that want to do harm to others would benefit from that technology too - you sure you still want that?
Also humans would degenerate even more not moving their limbs
---------- Post updated 11-03-10 at 01:02 PM ---------- Previous update was 11-02-10 at 04:59 PM ----------
@zxmaus
Not a solar powered notebook but at least a keyboard - Logitech will bring such a device on the market in the middle of November:
Click me!
These 2 Users Gave Thanks to zaxxon For This Post:
6 More Discussions You Might Find Interesting
1. Linux
I would like to know more about SIP technology (Session Initiation Protocol).
I have some trouble with SIP eXpress router and VoIP trasfer from server to client .
-The server is working and the client uses Xtensoftphone but the client can not to register in server .
-I need some more... (0 Replies)
Discussion started by: hydra
0 Replies
2. AIX
Hi Guys
I am currently running AIX 5.3 technology level 6 on a 570, but want to go up to level 9.
However I am struggling to find on IBM's website the new features that it brings in, along with the commands for these new features.
Can any one help me with this?
Thanks (7 Replies)
Discussion started by: ryanbsc@gmail.c
7 Replies
3. AIX
Hello
I update one lpar from TL03 to TL06 reboot and check with lppchk -v, errpt and everything looks fine then I commit my fileset and I update to TL08-04.
The installation was ok. I reboot my machine again check with lppchk -v and errpt and its ok, but when I type oslevel -s I get this... (5 Replies)
Discussion started by: lo-lp-kl
5 Replies
4. Shell Programming and Scripting
Hi Experts,
This may sound stupidity.....anyhow....let me ask the doubt, Even though shell is just a scripting language, can anyone tell me, whether web pages can be created with embedding some concepts.
In any other scripting language, whether web pages can be created. If so, suggest me in... (6 Replies)
Discussion started by: kritibalu
6 Replies
5. Web Development
Hi,
Home ~ InfoBeans
I want to know technology framework using which we can achieve that kind of look and feel
Thanks (6 Replies)
Discussion started by: ezee
6 Replies
6. What is on Your Mind?
It came in a template full of techy-related stickers for laptop (like Docker, K8s, BigData, RHEL, AWS, etc) but I have no clue what it represents. Any idea?
https://i.imgur.com/7ILp105.png
Thanks. (7 Replies)
Discussion started by: verdepollo
7 Replies
LEARN ABOUT FREEBSD
mge-shut
MGE-SHUT(8) NUT Manual MGE-SHUT(8)
NAME
mge-shut - Driver for SHUT Protocol UPS equipment
SYNOPSIS
mge-shut -h
mge-shut -a UPS_NAME [OPTIONS]
Note
This man page only documents the hardware-specific features of the mge-shut driver. For information about the core driver, see
nutupsdrv(8).
SUPPORTED HARDWARE
mge-shut supports all recent Eaton, MGE and Dell UPS models which use the SHUT (Serial HID UPS Transfer) protocol.
Older MGE models, such as Pulsar ESV+, Pulsar EX and Pulsar ES+, use the U-Talk protocol and should use the mge-utalk driver.
EXTRA ARGUMENTS
This driver also supports the following optional settings:
lowbatt=num
Set the low battery warning threshold at which shutdown is initiated by upsmon(8).
The factory default value is 30 (in percent), and can be settable depending on the exact model.
offdelay=num
Set the timer before the UPS is turned off after the kill power command is sent (via the -k switch).
The default value is 20 (in seconds). Usually this must be lower than ondelay, but the driver will not warn you upon startup if it
isn't.
ondelay=num
Set the timer for the UPS to switch on in case the power returns after the kill power command had been sent but before the actual
switch off. This ensures the machines connected to the UPS are, in all cases, rebooted after a power failure.
The default value is 30 (in seconds). Usually this must be greater than offdelay, but the driver will not warn you upon startup if it
isn't. Some UPS'es will restart no matter what, even if the power is (still) out at the moment this timer elapses. In that case, you
could try if setting ondelay = -1 in ups.conf helps.
notification=num
Set notification type to 1 (no), 2 (light) or 3 (yes).
The default value is 3 (yes) because of some early Ellipse models which need it.
KNOWN ISSUES
Repetitive timeout and staleness
Some models tends to be unresponsive with the default polling frequency. The result is that you have some "data stale" errors in your
system log.
In this case, simply modify the general parameter "pollinterval" to a higher value (like 10 for 10 seconds). This should solve the issue.
Using notification=3 might also help.
AUTHOR
Arnaud Quette
SEE ALSO
The core driver
nutupsdrv(8)
Internet resources
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 MGE-SHUT(8)