Operating Systems HP-UX FC port issue Post 302466349 by Sapfeer on Tuesday 26th of October 2010 08:30:06 AM
Old 10-26-2010
No, I don't think so... I'll check it



---------- Post updated at 16:30 ---------- Previous update was at 15:58 ----------




I've just restarted the port on SAN. Take a look at the logs:

Code:
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: 0/2/1/1: Fibre Channel Driver received Link Dead Notification.
Oct 26 15:26:10 terumos-bckp-srv2 vmunix:
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: class : tgtpath, instance 13
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: class : tgtpath, instance 14
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=13) has gone offline.  The target path h/w path is 0/2/1/1.0x500110a0005a5be2
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=14) has gone offline.  The target path h/w path is 0/2/1/1.0x500110a0005a5bdc
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: class : tgtpath, instance 12
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=12) has gone offline.  The target path h/w path is 0/2/1/1.0x100000e00244038d
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: class : tgtpath, instance 11
Oct 26 15:26:10 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=11) has gone offline.  The target path h/w path is 0/2/1/1.0x500110a0005a5bdf
Oct 26 15:26:15 terumos-bckp-srv2 EMS [2388]: ------ EMS Event Notification ------   Value: "CRITICAL (5)" for Resource: "/adapters/events/ql_adapter/0_2_1_1"     (Threshold:  >= "
 3")    Execute the following command to obtain event details:   /opt/resmon/bin/resdata -R 156499973 -r /adapters/events/ql_adapter/0_2_1_1 -n 156499974 -a
Oct 26 15:26:10 terumos-bckp-srv2 vmunix:
Oct 26 15:26:15 terumos-bckp-srv2  above message repeats 4 times
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: class : tgtpath, instance 12
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=12) has gone online.  The target path h/w path is 0/2/1/1.0x100000e00244038d
Oct 26 15:27:09 terumos-bckp-srv2 vmunix:
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: class : tgtpath, instance 14
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=14) has gone online.  The target path h/w path is 0/2/1/1.0x500110a0005a5bdc
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: class : tgtpath, instance 11
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=11) has gone online.  The target path h/w path is 0/2/1/1.0x500110a0005a5bdf
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: class : tgtpath, instance 13
Oct 26 15:27:09 terumos-bckp-srv2 vmunix: Target path (class=tgtpath, instance=13) has gone online.  The target path h/w path is 0/2/1/1.0x500110a0005a5be2


Last edited by Sapfeer; 10-26-2010 at 09:09 AM..
 

10 More Discussions You Might Find Interesting

1. HP-UX

PXE boot port issue

Hi,all: I want to boot an IA unix box from network, I am sure I set the DHCP and boot server, but it still failed ! It says : Client MAC Address: 00 18 FE 28 91 82 .....- PXE-E16: Valid PXE offer not received. Load of Core LAN Gb A failed: Not Found I use the nettl command to trace the UDP... (0 Replies)
Discussion started by: bluepluto
0 Replies

2. Solaris

Serial port issue

Hi, I am working with Sun Solaris 9 Sparc,Sun-Blade-100.In my application,I need to monitor the UPS using Serial port. When I am using JRE 1.4 in my application,I am able to monitor it but when I am upgrading the JRE version from 1.4 to JRE1.6. I am not able to monitor the UPS.It is showing the... (1 Reply)
Discussion started by: smartgupta
1 Replies

3. AIX

Port hang issue in AIX Version 5.3

On AIX platform we are having Weblogic 8.1 as the middleware for an application. The application is deployed in Weblogic on AIX platform and the server is having 2 dedicated listening ports for any incoming requests. Output for netstat -an command for the port 30001 is as follows:- tcp4... (7 Replies)
Discussion started by: subharai
7 Replies

4. Programming

Locking issue with serial port

Hi, In my application,I need to monitor the devices connected through serial port in solaris sparc 9 OS.I used c and java code for it and I am able to do the same but the problem comes when I restart the system and the open my application and try to monitor it.but I m unable to monitor the... (2 Replies)
Discussion started by: smartgupta
2 Replies

5. Red Hat

Help needed in fixing port issue - Urgent

Hi, One of our web application is running in Linux and using apache web servers. Application is hosted in port 4080 (for soap requests) and port 9999, and its serving behind a vip and cname. Initially it was working fine in another server and recently (2 months back) we have moved to the new... (4 Replies)
Discussion started by: senor.ram
4 Replies

6. Red Hat

HP Data Protector port 5555 issue

Dear All, I have my HP Data Protector installed on the backup server. I want to connect this backup server with the client server through telnet port 5555 like below telnet < ipaddress of client> 5555 But when I try like this , it says ...Connection refused ...unable to connect to... (0 Replies)
Discussion started by: jegaraman
0 Replies

7. IP Networking

port state issue

Hello, I have following issue: traceroute connection works to given address(ip + port) but telnet(and other network tools) do not. How it is possible? telnet 10.150.184.225 443 Connection refused tracert -T -p 443 10.150.184.225 traceroute to 10.150.184.225 (10.150.184.225), 30 hops... (3 Replies)
Discussion started by: kuba7
3 Replies

8. IP Networking

Facing issue in ip6table rule for port based routing management

Hi, Please help me on issue described below, I have 4 machine setup, M1 -> M2 -> M3 | M4. And A laptop that can be reachable through both M3 and M4. M2 has 2 NIC conected to M3 and M4. Now I want to divide the flow coming from M1 for laptop. At M2, I have done following,... (1 Reply)
Discussion started by: rahulbhansali24
1 Replies

9. IP Networking

Port forwarding issue

hi guys i have a simple question ! i have two ips . a valid and internal(172.16.11.2) i want to use port forwarding to forward any request to valid IP port 8001 to internal ip port 80 . i use this rule : sysctl -w net.ipv4.ip_forward=1 iptables -t nat -A PREROUTING -p tcp... (1 Reply)
Discussion started by: mhs
1 Replies

10. Solaris

How to find port number wwn of particular port on dual port HBA,?

please find the below o/p for your reference bash-3.00# fcinfo hba-port HBA Port WWN: 21000024ff295a34 OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3356-02 Firmware Version: 05.03.02 FCode/BIOS Version: BIOS: 2.02; fcode: 2.01;... (3 Replies)
Discussion started by: sb200
3 Replies
st_san_safe(5)							     OBSOLETED							    st_san_safe(5)

NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED) VALUES
Failsafe Default Allowed values Recommended values or DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_san_safe(5)
All times are GMT -4. The time now is 12:57 PM.