Does this application use a database? If so, which one?
Is it a web application? Network application?
10 More Discussions You Might Find Interesting
1. Linux
Hi, new here and need some help. Sometimes my site is extremely slow, if when there aren't too many people on, whereas when there are over 300 online members the site may be very fast. We use CentOS, PHP 5.26. The server has 4GB and Plesk usually shows about 2 or 3 GB free.
I believe I can see... (4 Replies)
Discussion started by: pspace
4 Replies
2. Solaris
Hello Friends,
On one of my Solaris 10 box, CPU usage shows 100% using "sar", "vmstat". However, it has 4 CPUs and prstat and glance are not showing enough processes to justify high CPU utilization.
=========================================================================
$ prstat -a
... (4 Replies)
Discussion started by: mahive
4 Replies
3. AIX
Hi Guys,
I need to write a script capable of identifying when a high cpu utilitzation process. It sounds simple but we are on a AIX 5.3 environment with Virtual CPU's (VP's) and logical CPU's. Please any ideas or tips would be highly appreciated. Thanks.
Harby. (6 Replies)
Discussion started by: arizah
6 Replies
4. AIX
ibm tivoli monitor's kuxagent is taking up a lot of cpu usage.
anybody has any idea? i attatched a screenshot. (3 Replies)
Discussion started by: curtis911
3 Replies
5. Linux
Hi All,
Yesterday my Linux server went panic and even a small command took a lot of time to run.
When i monitored pl find the below output
Cpu(s): 0.1%us, 98.4%sy, 0.0%ni, 1.5%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st
the time spent on kernel mode is 98 % and also idle time is around 1.5 %...... (4 Replies)
Discussion started by: jegaraman
4 Replies
6. AIX
Hi,
I can't seem to make sense of this. My wait time is showing really high but vmstat's and topas are showing normal usage.
ps aux
USER PID %CPU %MEM SZ RSS TTY STAT STIME TIME COMMAND
root 9961810 5680.7 0.0 448 384 - A Dec 16 6703072:12 wait
... (2 Replies)
Discussion started by: techy1
2 Replies
7. AIX
Dear All,
One production Server is affected by high usage.
Application is slow now. Please guide me how to solve it?
NMON Report shows full cpu usage.
Here im posting some server details.
bash-3.2# lparstat -i
Node Name : *********
Partition Name ... (6 Replies)
Discussion started by: Thala
6 Replies
8. Shell Programming and Scripting
I have created one script and i have added it into cron to run after 10 mins. However I have noted that whenever that script runs, It causes CPU utilization of server to increase about 10-20 %
I have rechecked script and there is no way i can make changes, Script contain only 2-3 commands. So... (4 Replies)
Discussion started by: Nakul_sh
4 Replies
9. Solaris
HI
In my M5000 , one of domain is having SAp installed. from today onwards we are facing some stange issue.
when we start SAP application, that particular user is taking 95 % of system CP and renaming 5 % is taken by system . because of this reason application is slow.
i have 4 CPU(32... (4 Replies)
Discussion started by: bentech4u
4 Replies
10. UNIX for Advanced & Expert Users
Hi Fellas,
Not sure how I can dig in even further but we notice that one of our DB servers is showing high Sys% CPU usage even though when I execute the following command :
I can see that postgres is the only one using the CPU. So if anyone can advise me what would be the best way to... (3 Replies)
Discussion started by: arizah
3 Replies
LEARN ABOUT NETBSD
arcmsr
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)
NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)
HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD
March 3, 2008 BSD