09-30-2010
Thanks Bluescreen,
That would actually work unfortunately we don't have any internal drives which is causing me a lot of headaches.
10 More Discussions You Might Find Interesting
1. Solaris
Hi All,
I have one question.
I found out that my system setting for mpxio-disable=yes. Sun recommend to change it to mpxio-disable=no and run stmsboot -e command.
But no one can tell will it affect the system or not and the system is sol-10 and using veritas volume manager and attached... (3 Replies)
Discussion started by: mailbox80
3 Replies
2. Solaris
Hi,
I have a quick question.
How can I see MPXIO statistics (like errors, how many I/O|throuput per path, ....) on Solaris 10? Does maybe a ready dtrace script exist (I do not have the knowledge to write one myself)?
I would be happy if somebody knows some good documentation/links (with... (1 Reply)
Discussion started by: victorinox
1 Replies
3. Solaris
How to change the following values in power path from SP B to SP A ?
Owner: default=SP B, current=SP B
this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies
4. AIX
Hi Guys,
I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one.
I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors:
... (4 Replies)
Discussion started by: zxmaus
4 Replies
5. Red Hat
Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies
6. Solaris
Hi Kudo,
I wanna to know that how can I do mpxio device name to os native name mapping without using stmsboot -L I tried everything still not able to got the solution till I able to get these o/p
here is native disk info as well physical wat is the logical OS name of the disk
... (1 Reply)
Discussion started by: tarunn.dubeyy
1 Replies
7. Solaris
Hello,
I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN.
This is the situation :
Server is a SUN Enterprise M5000
OS = Solaris10 Sparc
Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies
8. Linux
Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3.
I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process:
echo "1" > /sys/class/fc_host/host<n>/issue_lip
and
echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies
9. Solaris
Hi all
I am running the following hardware:
2 SUN Solaris 10 machines
They are connected to EMC clarion LUNs
We are running a Sun Cluster 3.2 managing both nodes
We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies
10. Solaris
It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies
LEARN ABOUT DEBIAN
array-info
array-info(1) array-info(1)
NAME
array-info - check the status of a HP (Compaq) SmartArray controller
SYNOPSIS
array-info -d array_device_path [-a|-l|-A|-c|-s|-L|-h]
DESCRIPTION
Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA
and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the con-
troller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive.
OPTIONS
--device | -d
Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1
--all-drives | -a
Show informations about all drives
--logical drive | -l
Show informations about selected logical drive
--show-ctrl | -c
Show informations about controller
--show-logical | -L
Show informations about logical drives
--show-physical | -p
Show physical device informations
--show-status | -s
Show status of logical drives
--show-all | -A
Show all informations
--version | -V
Show version
-h Show help about options
COPYRIGHT
This manual page was written by Raphael Pinson <<raphink@ubuntu.com>>. Permission is granted to copy, distribute and/or modify this docu-
ment under the terms of the GNU General Public License, Version 2 or any later version published by the Free Software Foundation.
2006-12-15 array-info(1)