Sponsored Content
Operating Systems Solaris Migrate from MPXIO to Powerpath Post 302458319 by nabru72 on Thursday 30th of September 2010 11:15:38 AM
Old 09-30-2010
Thanks Bluescreen,

That would actually work unfortunately we don't have any internal drives which is causing me a lot of headaches.
 

10 More Discussions You Might Find Interesting

1. Solaris

Mpxio

Hi All, I have one question. I found out that my system setting for mpxio-disable=yes. Sun recommend to change it to mpxio-disable=no and run stmsboot -e command. But no one can tell will it affect the system or not and the system is sol-10 and using veritas volume manager and attached... (3 Replies)
Discussion started by: mailbox80
3 Replies

2. Solaris

Mpxio

Hi, I have a quick question. How can I see MPXIO statistics (like errors, how many I/O|throuput per path, ....) on Solaris 10? Does maybe a ready dtrace script exist (I do not have the knowledge to write one myself)? I would be happy if somebody knows some good documentation/links (with... (1 Reply)
Discussion started by: victorinox
1 Replies

3. Solaris

change SP value in powerpath

How to change the following values in power path from SP B to SP A ? Owner: default=SP B, current=SP B this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies

4. AIX

Cannot uninstall powerpath - bosboot issues

Hi Guys, I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one. I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors: ... (4 Replies)
Discussion started by: zxmaus
4 Replies

5. Red Hat

Configure EMC Powerpath?

Hi , I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies

6. Solaris

MPXIO

Hi Kudo, I wanna to know that how can I do mpxio device name to os native name mapping without using stmsboot -L I tried everything still not able to got the solution till I able to get these o/p here is native disk info as well physical wat is the logical OS name of the disk ... (1 Reply)
Discussion started by: tarunn.dubeyy
1 Replies

7. Solaris

Solaris 10 with Veritas and PowerPath

Hello, I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN. This is the situation : Server is a SUN Enterprise M5000 OS = Solaris10 Sparc Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies

8. Linux

EMC, PowerPath and issue on using LUN

Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3. I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process: echo "1" > /sys/class/fc_host/host<n>/issue_lip and echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies

9. Solaris

Powerpath upgrade with SVM disksets

Hi all I am running the following hardware: 2 SUN Solaris 10 machines They are connected to EMC clarion LUNs We are running a Sun Cluster 3.2 managing both nodes We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies

10. Solaris

One emc powerpath failed

It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies
array-info(1)															     array-info(1)

NAME
array-info - check the status of a HP (Compaq) SmartArray controller SYNOPSIS
array-info -d array_device_path [-a|-l|-A|-c|-s|-L|-h] DESCRIPTION
Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the con- troller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive. OPTIONS
--device | -d Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1 --all-drives | -a Show informations about all drives --logical drive | -l Show informations about selected logical drive --show-ctrl | -c Show informations about controller --show-logical | -L Show informations about logical drives --show-physical | -p Show physical device informations --show-status | -s Show status of logical drives --show-all | -A Show all informations --version | -V Show version -h Show help about options COPYRIGHT
This manual page was written by Raphael Pinson <<raphink@ubuntu.com>>. Permission is granted to copy, distribute and/or modify this docu- ment under the terms of the GNU General Public License, Version 2 or any later version published by the Free Software Foundation. 2006-12-15 array-info(1)
All times are GMT -4. The time now is 05:29 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy