Sponsored Content
Full Discussion: stop raid mean what
Operating Systems Linux stop raid mean what Post 302451716 by ZR_Lang on Tuesday 7th of September 2010 11:09:18 PM
Old 09-08-2010
Question stop raid mean what

Hello, recently I worked about RAID (soft Raid), I use mdadm command. There are some questions, for example:
1, I make a RAID named /dev/md0.
Code:
mdadm -C -v /dev/md0 -l1 -n2 -x1 /dev/hda1 /dev/hdb1 /dev/hdc1

2, Then I stop it.
Code:
mdadm -S /dev/md0

3, Then I make another RAID also named /dev/md0, and I can do it.
Code:
mdadm -C -v /dev/md0 -l0 -n2 /dev/hda2 /dev/hdb2

4, Then I use "/dev/hda1 /dev/hdb1 /dev/hdc1" which belong the old md0 be stopped to make a new RAID named /dev/md1. I can do it, but just I need say "yes".
Code:
localhost:~/mkraid # mdadm -C -v /dev/md1 -l1 -n2 -x1 /dev/hda1 /dev/hdb1 /dev/hdc1
mdadm: layout defaults to left-symmetric
mdadm: chunk size defaults to 64K
mdadm: /dev/hda1 appears to be part of a raid array:
    level=raid1 devices=2 ctime=Wed Sep  8 09:08:47 2010
mdadm: /dev/hdb1 appears to be part of a raid array:
    level=raid5 devices=2 ctime=Wed Sep  8 09:08:47 2010
mdadm: /dev/hdc1 appears to be part of a raid array:
    level=raid5 devices=2 ctime=Wed Sep  8 09:08:47 2010
mdadm: size set to 97216K
Continue creating array? yes
mdadm: array /dev/md1 started.

One:
I hope to know, I made new RAID named same as an old RAID be stopped, and used devices belong to the old RAID be stopped like what I said above. Is it allright? There are any affect? How could I deal with the old RAID be stopped except active it?

Two:
I am writing a program and I need to get the message of old partition has exist. I don't know how to deal with the message of old be stopped RAID. Don't touch it just show it has been stopped wait for deal later or don't care about it just deal it as the devices which can be used as usual?

Thank you very much for your help.

Last edited by pludi; 09-08-2010 at 02:21 AM..
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

how to stop others users to stop viewing what i am doing ?

Hi , I have one question, suppose i am a normal user and when i use 'w' command , it shows who is logged on and what they are doing . Now i want to stop others users to know what i am doing accept the root ? can i do this ? thanks (5 Replies)
Discussion started by: mobile01
5 Replies

2. HP-UX

RAID 5 on HP-UX

Hi, i had search through this forum about the RAID 5 configurations on HPUX server (model RP5470) but only find this thread: https://www.unix.com/hp-ux/23910-raid-0-unix.html .. there are two way to configure the RAID that provided from this thread RAID 0 **************** #!/bin/sh... (7 Replies)
Discussion started by: amme_psycho
7 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. Solaris

implementing RAID 1 from RAID 5

Dear ALl, I have a RAID 5 volume which is as below d120 r 60GB c1t2d0s5 c1t3d0s5 c1t4d0s5 c1t5d0s5 d7 r 99GB c1t2d0s0 c1t3d0s0 c1t4d0s0 c1t5d0s0 d110 r 99GB c1t2d0s4 c1t3d0s4 c1t4d0s4 c1t5d0s4 d8 r 99GB c1t2d0s1 c1t3d0s1... (2 Replies)
Discussion started by: jegaraman
2 Replies

5. Solaris

Creation of Raid 01 and Raid 10

Hello All, I have read enough of texts on Raid 01 and Raid 10 on solaris :wall: . But no-where found a way to create them using SVM. Some one pls tell me how to do or Post some link if that helps. TIA Curious solarister (1 Reply)
Discussion started by: Solarister
1 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. UNIX for Dummies Questions & Answers

Need help with RAID.

Hi Gurus, Can any one explain me the difference between hardware RAID and s/w RAID. Thanks in Advance. (1 Reply)
Discussion started by: rama krishna
1 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
mdadm_selinux(8)					       SELinux Policy mdadm						  mdadm_selinux(8)

NAME
mdadm_selinux - Security Enhanced Linux Policy for the mdadm processes DESCRIPTION
Security-Enhanced Linux secures the mdadm processes via flexible mandatory access control. The mdadm processes execute with the mdadm_t SELinux type. You can check if you have these processes running by executing the ps command with the -Z qualifier. For example: ps -eZ | grep mdadm_t ENTRYPOINTS
The mdadm_t SELinux type can be entered via the mdadm_exec_t file type. The default entrypoint paths for the mdadm_t domain are the following: /sbin/mdadm, /sbin/mdmon, /sbin/mdmpd, /sbin/iprdump, /sbin/iprinit, /sbin/iprupdate, /usr/sbin/mdadm, /usr/sbin/mdmpd, /usr/sbin/mdmon, /sbin/raid-check, /usr/sbin/iprdump, /usr/sbin/iprinit, /usr/sbin/iprupdate, /usr/sbin/raid-check PROCESS TYPES
SELinux defines process types (domains) for each process running on the system You can see the context of a process using the -Z option to ps Policy governs the access confined processes have to files. SELinux mdadm policy is very flexible allowing users to setup their mdadm pro- cesses in as secure a method as possible. The following process types are defined for mdadm: mdadm_t Note: semanage permissive -a mdadm_t can be used to make the process type mdadm_t permissive. SELinux does not deny access to permissive process types, but the AVC (SELinux denials) messages are still generated. BOOLEANS
SELinux policy is customizable based on least access required. mdadm policy is extremely flexible and has several booleans that allow you to manipulate the policy and run mdadm with the tightest access possible. If you want to allow users to resolve user passwd entries directly from ldap rather then using a sssd server, you must turn on the authlo- gin_nsswitch_use_ldap boolean. Disabled by default. setsebool -P authlogin_nsswitch_use_ldap 1 If you want to allow all daemons to write corefiles to /, you must turn on the daemons_dump_core boolean. Disabled by default. setsebool -P daemons_dump_core 1 If you want to enable cluster mode for daemons, you must turn on the daemons_enable_cluster_mode boolean. Enabled by default. setsebool -P daemons_enable_cluster_mode 1 If you want to allow all daemons to use tcp wrappers, you must turn on the daemons_use_tcp_wrapper boolean. Disabled by default. setsebool -P daemons_use_tcp_wrapper 1 If you want to allow all daemons the ability to read/write terminals, you must turn on the daemons_use_tty boolean. Disabled by default. setsebool -P daemons_use_tty 1 If you want to deny any process from ptracing or debugging any other processes, you must turn on the deny_ptrace boolean. Enabled by default. setsebool -P deny_ptrace 1 If you want to allow all domains to use other domains file descriptors, you must turn on the domain_fd_use boolean. Enabled by default. setsebool -P domain_fd_use 1 If you want to allow all domains to have the kernel load modules, you must turn on the domain_kernel_load_modules boolean. Disabled by default. setsebool -P domain_kernel_load_modules 1 If you want to allow all domains to execute in fips_mode, you must turn on the fips_mode boolean. Enabled by default. setsebool -P fips_mode 1 If you want to enable reading of urandom for all domains, you must turn on the global_ssp boolean. Disabled by default. setsebool -P global_ssp 1 If you want to allow confined applications to run with kerberos, you must turn on the kerberos_enabled boolean. Enabled by default. setsebool -P kerberos_enabled 1 If you want to allow system to run with NIS, you must turn on the nis_enabled boolean. Disabled by default. setsebool -P nis_enabled 1 If you want to allow confined applications to use nscd shared memory, you must turn on the nscd_use_shm boolean. Enabled by default. setsebool -P nscd_use_shm 1 NSSWITCH DOMAIN
If you want to allow users to resolve user passwd entries directly from ldap rather then using a sssd server for the mdadm_t, you must turn on the authlogin_nsswitch_use_ldap boolean. setsebool -P authlogin_nsswitch_use_ldap 1 If you want to allow confined applications to run with kerberos for the mdadm_t, you must turn on the kerberos_enabled boolean. setsebool -P kerberos_enabled 1 MANAGED FILES
The SELinux process type mdadm_t can manage files labeled with the following file types. The paths listed are the default paths for these file types. Note the processes UID still need to have DAC permissions. cgroup_t /cgroup(/.*)? /sys/fs/cgroup(/.*)? cluster_conf_t /etc/cluster(/.*)? cluster_var_lib_t /var/lib/pcsd(/.*)? /var/lib/cluster(/.*)? /var/lib/openais(/.*)? /var/lib/pengine(/.*)? /var/lib/corosync(/.*)? /usr/lib/heartbeat(/.*)? /var/lib/heartbeat(/.*)? /var/lib/pacemaker(/.*)? cluster_var_run_t /var/run/crm(/.*)? /var/run/cman_.* /var/run/rsctmp(/.*)? /var/run/aisexec.* /var/run/heartbeat(/.*)? /var/run/cpglockd.pid /var/run/corosync.pid /var/run/rgmanager.pid /var/run/cluster/rgmanager.sk kdump_lock_t /var/lock/kdump(/.*)? kdumpctl_tmp_t mdadm_conf_t /etc/mdadm.conf mdadm_tmp_t mdadm_tmpfs_t mdadm_var_run_t /dev/md/.* /var/run/mdadm(/.*)? /dev/.mdadm.map root_t / /initrd sysfs_t /sys(/.*)? systemd_passwd_var_run_t /var/run/systemd/ask-password(/.*)? /var/run/systemd/ask-password-block(/.*)? FILE CONTEXTS
SELinux requires files to have an extended attribute to define the file type. You can see the context of a file using the -Z option to ls Policy governs the access confined processes have to these files. SELinux mdadm policy is very flexible allowing users to setup their mdadm processes in as secure a method as possible. STANDARD FILE CONTEXT SELinux defines the file context types for the mdadm, if you wanted to store files with these types in a diffent paths, you need to execute the semanage command to sepecify alternate labeling and then use restorecon to put the labels on disk. semanage fcontext -a -t mdadm_conf_t '/srv/mdadm/content(/.*)?' restorecon -R -v /srv/mymdadm_content Note: SELinux often uses regular expressions to specify labels that match multiple files. The following file types are defined for mdadm: mdadm_conf_t - Set files with the mdadm_conf_t type, if you want to treat the files as mdadm configuration data, usually stored under the /etc direc- tory. mdadm_exec_t - Set files with the mdadm_exec_t type, if you want to transition an executable to the mdadm_t domain. Paths: /sbin/mdadm, /sbin/mdmon, /sbin/mdmpd, /sbin/iprdump, /sbin/iprinit, /sbin/iprupdate, /usr/sbin/mdadm, /usr/sbin/mdmpd, /usr/sbin/mdmon, /sbin/raid-check, /usr/sbin/iprdump, /usr/sbin/iprinit, /usr/sbin/iprupdate, /usr/sbin/raid-check mdadm_initrc_exec_t - Set files with the mdadm_initrc_exec_t type, if you want to transition an executable to the mdadm_initrc_t domain. mdadm_tmp_t - Set files with the mdadm_tmp_t type, if you want to store mdadm temporary files in the /tmp directories. mdadm_tmpfs_t - Set files with the mdadm_tmpfs_t type, if you want to store mdadm files on a tmpfs file system. mdadm_unit_file_t - Set files with the mdadm_unit_file_t type, if you want to treat the files as mdadm unit content. Paths: /usr/lib/systemd/system/mdmon@.*, /usr/lib/systemd/system/mdmonitor.* mdadm_var_run_t - Set files with the mdadm_var_run_t type, if you want to store the mdadm files under the /run or /var/run directory. Paths: /dev/md/.*, /var/run/mdadm(/.*)?, /dev/.mdadm.map Note: File context can be temporarily modified with the chcon command. If you want to permanently change the file context you need to use the semanage fcontext command. This will modify the SELinux labeling database. You will need to use restorecon to apply the labels. COMMANDS
semanage fcontext can also be used to manipulate default file context mappings. semanage permissive can also be used to manipulate whether or not a process type is permissive. semanage module can also be used to enable/disable/install/remove policy modules. semanage boolean can also be used to manipulate the booleans system-config-selinux is a GUI tool available to customize SELinux policy settings. AUTHOR
This manual page was auto-generated using sepolicy manpage . SEE ALSO
selinux(8), mdadm(8), semanage(8), restorecon(8), chcon(1), sepolicy(8) , setsebool(8) mdadm 14-06-10 mdadm_selinux(8)
All times are GMT -4. The time now is 01:00 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy