Hi,
How we can use use plink to access unix system using Dos.
Could someone send me the commands that can be use in Batch file to call unix system using plink utility.
Thanks in advance (0 Replies)
Hello. I have a TCL script that logs in to a server using SSH. As SSH isn't available in windows,I used Plink to do the job.The script works fine on my PC and 2 of my friend's PC.
However, on one PC, I get the following error message:
"'D:\scripts\plink.exe' is not a Win32 Console... (1 Reply)
Hi,
I'm testing out this plink script - which will be executed to shutdown multiple LPARs.
This consists from:
plink -i /path/ssh/cert/ root@host shutdown -F
plink -i /path/ssh/cert/ root@host2 shutdown -F
The commands gets executed, however it stops on one host, and does not move... (6 Replies)
I'm using plink.exe on WinXP to run some commands on Z/OS BASH. My commands are interspersed with echo commands so that I can parse the output and work out what is where.
The first hundred or so commands run fine, but then one of them gets truncated. For example:
Input:
echo :end_logdetail:... (6 Replies)
Hi Plink users,
I am very new in GWAS and decided to use PLINK for this. But I am struggling with file formats.
I have one exome data with 200000 SNPs in it. But it is in .txt format. But all the necessary fields are there in different columns.
Can you please suggest me how I can create the... (5 Replies)
Hi All,
Iam a newbie to the plink and need your assistance. I have referred some posts but it doesn't helps me much.
I have two steps to do.
1. I have a config file which has a list of servers,username and password.
2. I have a shell script in windows which accepts arguments and need to... (0 Replies)
I have similar issue as mentioned in
167174-how-run-script-using-batch-file.html
It works good, but the control is not coming back to source i tried adding exit to remote script.
Thanks,
Suresh (0 Replies)
I had a simple automation process to take config backup from san switches to windows via SSH. This can be accomplished using plink.
My script was working fine earlier but from last few days it is not collecting data and the error which i am getting is below.
"":confused:
I have done the... (6 Replies)
Hi,
I have run into a problem to which i can't seem to find any solution, posting here is my last resort.
Problem:
I am using plink to access my router and run a few configuration commands. When in enter configurations mode, instead of sending next command plink keeps on waiting for manual... (7 Replies)
Hi,
I am executing below command from Windows run and it is not working
"C:\Program Files (x86)\PuTTY\pageant.exe" "D:\abc_key.ppk" -c "C:\Program Files (x86)\PuTTY\plink.exe" -ssh 172.19.11.134 sh ~/touchfile.sh
I have created a .ppk file in the directory specified
The plink window... (2 Replies)
Discussion started by: NP1
2 Replies
LEARN ABOUT DEBIAN
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.9.0-pre1 October 2010 IRSEND(1)