Sponsored Content
Top Forums UNIX for Dummies Questions & Answers How to find which raid is configured(without restart) Post 302449326 by pludi on Monday 30th of August 2010 07:57:26 AM
Old 08-30-2010
Software RAID (quick and dirty):
Code:
for i in /dev/md*; do printf '%s: %s\n' $i "$( sudo /sbin/mdadm --detail $i 2>/dev/null | grep 'Raid Level' )"; done

For hardware RAID it depends on the vendor of the RAID card and whether or not the according utilities have been installed.
 

9 More Discussions You Might Find Interesting

1. Slackware

LDAP not getting configured!!!

hi, i m tryin to learn ldap. but its not getting configured. the error msg it shows is: LDAP configure error: BDB/HDB : Berkeley DB version incompatibe. The BDB version i have installed is bdb4.2.52 and the ldap version is openldap-2.3.12. my machine is running on red hat linux 9. Why... (1 Reply)
Discussion started by: mridula
1 Replies

2. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

3. Red Hat

How to Find what HBA is configured on Linux?

Hi I am working in an environment where there are many redhat physical and virtual machines, mostly Redhat 4. These servers have LUNs attached. The external storage can be EMC, NetApp or Par3. My question is that when Storage Administrator informs that a new LUN has been presented to a... (4 Replies)
Discussion started by: Tirmazi
4 Replies

4. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

5. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

6. HP-UX

Script to find what netprinters are configured with what model

Following this thread : https://www.unix.com/hp-ux/189023-solved-way-tell-printer-used-configured-print-queue.html This is rwuerth's nice contribution! I had a more complicated script written a long time ago to find out this information, but after realizing due to VBE's post (thank you VBE)... (0 Replies)
Discussion started by: rwuerth
0 Replies

7. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

8. IP Networking

IP not configured is being used to login

Hi have a solaris server with the following IP 192.168.0.85, but anybody can login in using 172.19.0.85, and the ifconfigcommand does not show the 172.19.05 . # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask... (6 Replies)
Discussion started by: fretagi
6 Replies

9. Linux

Find a process ID,kill it and restart agent

#!/bin/bash #This shell finds the pid of the hawkagent and kills and restarts to put the rulebase into effect output=`ps aux|grep hawkagent` #The set -- below helps to parse the above ps output into words and $2 gives the 2nd word which is pid set -- $output pid=$2 #Checks if pid of hawkagent... (12 Replies)
Discussion started by: samrat dutta
12 Replies
ARCMSR(4)						   BSD Kernel Interfaces Manual 						 ARCMSR(4)

NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller SYNOPSIS
arcmsr* at pci? dev ? function ? DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation: - ARC-1110 PCI-X 4 Port SATA RAID Controller - ARC-1110ML PCI-X 4 Port SATA RAID Controller - ARC-1120 PCI-X 8 Port SATA RAID Controller - ARC-1120ML PCI-X 8 Port SATA RAID Controller - ARC-1130 PCI-X 12 Port SATA RAID Controller - ARC-1130ML PCI-X 12 Port SATA RAID Controller - ARC-1160 PCI-X 16 Port SATA RAID Controller - ARC-1160ML PCI-X 16 Port SATA RAID Controller - ARC-1170 PCI-X 24 Port SATA RAID Controller - ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller - ARC-1202 PCI Express 2 Port SATA RAID Controller - ARC-1210 PCI Express 4 Port SATA RAID Controller - ARC-1220 PCI Express 8 Port SATA RAID Controller - ARC-1230 PCI Express 12 Port SATA RAID Controller - ARC-1230ML PCI Express 12 Port SATA RAID Controller - ARC-1231ML PCI Express 12 Port SATA RAID Controller - ARC-1260 PCI Express 16 Port SATA RAID Controller - ARC-1260ML PCI Express 16 Port SATA RAID Controller - ARC-1261ML PCI Express 16 Port SATA RAID Controller - ARC-1280 PCI Express 24 Port SATA RAID Controller - ARC-1280ML PCI Express 24 Port SATA RAID Controller - ARC-1680 PCI Express 8 Port SAS RAID Controller - ARC-1680LP PCI Express 8 Port SAS RAID Controller - ARC-1680i PCI Express 8 Port SAS RAID Controller - ARC-1680x PCI Express 8 Port SAS RAID Controller - ARC-1681 PCI-X 8 Port SAS RAID Controller These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives. arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands. Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8). When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol- lowing command (once the initialization is finished): $ scsictl scsibus0 scan any any The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the bioctl(8) command. EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8) HISTORY
The arcmsr driver first appeared in NetBSD 5.0. AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines. BSD
March 3, 2008 BSD
All times are GMT -4. The time now is 09:55 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy