Sponsored Content
Top Forums UNIX for Dummies Questions & Answers How to find which raid is configured(without restart) Post 302449313 by pinga123 on Monday 30th of August 2010 06:47:13 AM
Old 08-30-2010
How to find which raid is configured(without restart)

Is there a way to find the raid type without restarting the machine?

I m using linux operating system.
 

9 More Discussions You Might Find Interesting

1. Slackware

LDAP not getting configured!!!

hi, i m tryin to learn ldap. but its not getting configured. the error msg it shows is: LDAP configure error: BDB/HDB : Berkeley DB version incompatibe. The BDB version i have installed is bdb4.2.52 and the ldap version is openldap-2.3.12. my machine is running on red hat linux 9. Why... (1 Reply)
Discussion started by: mridula
1 Replies

2. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

3. Red Hat

How to Find what HBA is configured on Linux?

Hi I am working in an environment where there are many redhat physical and virtual machines, mostly Redhat 4. These servers have LUNs attached. The external storage can be EMC, NetApp or Par3. My question is that when Storage Administrator informs that a new LUN has been presented to a... (4 Replies)
Discussion started by: Tirmazi
4 Replies

4. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

5. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

6. HP-UX

Script to find what netprinters are configured with what model

Following this thread : https://www.unix.com/hp-ux/189023-solved-way-tell-printer-used-configured-print-queue.html This is rwuerth's nice contribution! I had a more complicated script written a long time ago to find out this information, but after realizing due to VBE's post (thank you VBE)... (0 Replies)
Discussion started by: rwuerth
0 Replies

7. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

8. IP Networking

IP not configured is being used to login

Hi have a solaris server with the following IP 192.168.0.85, but anybody can login in using 172.19.0.85, and the ifconfigcommand does not show the 172.19.05 . # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask... (6 Replies)
Discussion started by: fretagi
6 Replies

9. Linux

Find a process ID,kill it and restart agent

#!/bin/bash #This shell finds the pid of the hawkagent and kills and restarts to put the rulebase into effect output=`ps aux|grep hawkagent` #The set -- below helps to parse the above ps output into words and $2 gives the 2nd word which is pid set -- $output pid=$2 #Checks if pid of hawkagent... (12 Replies)
Discussion started by: samrat dutta
12 Replies
REBOOT(8)						    BSD System Manager's Manual 						 REBOOT(8)

NAME
reboot, poweroff, halt -- restarting, powering down and stopping the system SYNOPSIS
halt [-dlnpqvxz] poweroff [-dlnqvxz] reboot [-dlnqvxz] [arg ...] DESCRIPTION
The poweroff, halt and reboot utilities flush the file system cache to disk, send all running processes a SIGTERM, wait for up to 30 seconds for them to die, send a SIGKILL to the survivors and, respectively, power down, halt or restart the system. The action is logged, including entering a shutdown record into the login accounting file and sending a message via syslog(3). The options are as follows: -d Create a dump before halting or restarting. This option is useful for debugging system dump procedures or capturing the state of a corrupted or misbehaving system. -l Suppress sending a message via syslog(3) before halting or restarting. -n Do not flush the file system cache. This option should be used with extreme caution. It can be used if a disk or a processor is on fire. -p Attempt to powerdown the system. If the powerdown fails, or the system does not support software powerdown, the system will halt. This option is only valid for halt. -v To enable verbose messages on the console, pass the boothowto(9) flag AB_VERBOSE to reboot(2). -x To enable debugging messages on the console, pass the boothowto(9) flag AB_DEBUG to reboot(2). -z To silence some shutdown messages on the console, pass the boothowto(9) flag AB_SILENT to reboot(2). -q Do not give processes a chance to shut down before halting or restarting. This option should not normally be used. If there are any arguments passed to reboot they are concatenated with spaces and passed as bootstr to the reboot(2) system call. The string is passed to the firmware on platforms that support it. Normally, the shutdown(8) utility is used when the system needs to be halted or restarted, giving users advance warning of their impending doom. SEE ALSO
reboot(2), syslog(3), utmp(5), boot(8), init(8), rescue(8), shutdown(8), sync(8) HISTORY
A reboot command appeared in Version 6 AT&T UNIX. The poweroff command first appeared in NetBSD 1.5. CAVEATS
Once the command has begun its work, stopping it before it completes will probably result in a system so crippled it must be physically reset. To prevent premature termination, the command blocks many signals early in its execution. However, nothing can defend against delib- erate attempts to evade this. This command will stop the system without running any shutdown(8) scripts. Amongst other things, this means that swapping will not be dis- abled so that raid(4) can shutdown cleanly. You should normally use shutdown(8) unless you are running in single user mode. BUGS
The single user shell will ignore the SIGTERM signal. To avoid waiting for the timeout when rebooting or halting from the single user shell, you have to exec reboot or exec halt. BSD
February 16, 2011 BSD
All times are GMT -4. The time now is 02:35 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy