The steps after seeing the bootup error, after trying vxvol restart and resync, and seeing that the fstype showed problems? Just this:
Format:
Selected Disk 2.
Select Label.
exit out.
Then tried the newfs command above.

I have since used the vxvol with 2 added switches (-o and bg): vxvol -o bg -f start, which appears to be working. I was able to use the newfs command afterwards and it is syncing the drive now.

I hope this gets me out of the woods. If it is successful, I just need to mount the drive.
Thanks for the follow-up.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

stepping through ascii file

How can one step through an ascii file line by line looking for a word and then pull out the whole section that the word is in. I have a project working Oracles tkprof utility where I am trying to look for a word and need to pull out the section of the ascii file that the word is in. I have not... (12 Replies)
Discussion started by: rehoboth
12 Replies

2. UNIX for Dummies Questions & Answers

newfs, mounting, new partitions, HELP!!

Looking for a good online primer/intro to creating a new file system, mounting, and eventually using NFS. Do you use newfs then mount or mount then newfs, how do you work with a new partition to create a new file system.... it's all a bit confusing. The man pages are a little too verbose and... (1 Reply)
Discussion started by: charliewade
1 Replies

3. UNIX for Dummies Questions & Answers

Scripting stepping stones.

It's safe to say that I have had no scripting / programming experience before. I took a job as an AIX / Linux administrator, and I have found myself up to my ears in bash scripting. I'm starting to really catch on, I've become a casual linux user, to a hopeful future power user. I was... (2 Replies)
Discussion started by: syndex
2 Replies

4. Solaris

why cant i do a newfs?

what do you make of this ?? all I want to do is newfs a slice of disk..... # uname -a SunOS myhost 5.10 Generic_120011-14 sun4u sparc SUNW,Sun-Fire-V240 # cat /etc/release Solaris 10 8/07 s10s_u4wos_12b SPARC Copyright 2007 Sun Microsystems, Inc. All... (4 Replies)
Discussion started by: robsonde
4 Replies

5. Shell Programming and Scripting

Rsync script in cron from stepping on itself

I have the following rsync script that I use for syncing MySQL files from one server to another. I run the script at 20 minutes past every second hour in cron. I want to make sure that the script completes in it's entirety before it is set to kick off again. For example, when the script starts at... (3 Replies)
Discussion started by: sunsysadm2003
3 Replies

6. Linux

Stair stepping

Is there a command line flag to lpr or a utility similar to the Unix 'xtod' command to fix stair stepping when printing? Under Unix I would: # cat textfile | xtod | lp -d lineprinter Anything like that for linux? Thanks (1 Reply)
Discussion started by: lochraven
1 Replies

7. Solaris

newfs

Hi, can someone please help me create a newfs on my unix server ? thankyou venhart (7 Replies)
Discussion started by: venhart
7 Replies

8. Solaris

difference between mkfs and newfs

hi what is the difference between mkfs and newfs (2 Replies)
Discussion started by: madhudeepan
2 Replies

9. SCO

Stair-stepping printing

Hi, We have a Unix 3.2v5.0.5. I installed a printer via scoadmin, HP network printer manager with network peripheral name an ip-adress. I have a lot of trouble, the printer do stair-stepping. I know it is because of the translation LF to CR/LF. But it is impossible to set this correct in... (2 Replies)
Discussion started by: haezeban
2 Replies

10. Shell Programming and Scripting

Perl Debug Stepping Answering Questions

I am new to perl and want to get a little better understanding of debugging code in perl. I have a perl script that has questions to be answered like: he following PERL modules are recommended: Crypt::DES Crypt::PasswdMD5 IO::Pty Net::Write::Layer2 String::CRC32 Attempt to install... (0 Replies)
Discussion started by: metallica1973
0 Replies
vxrelocd(1M)															      vxrelocd(1M)

NAME
vxrelocd - monitor Veritas Volume Manager for failure events and relocate failed subdisks SYNOPSIS
/etc/vx/bin/vxrelocd [-o vxrecover_argument] [-O old_version] [-s save_max] [mail_address...] DESCRIPTION
The vxrelocd command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, and waits for a failure. When a failure occurs, vxrelocd sends mail via mailx to root (by default) or to other specified users and relocates failed subdisks. After com- pleting the relocation, vxrelocd sends more mail indicating the status of each subdisk replacement. The vxrecover utility is then run on volumes with relocated subdisks to restore data. Mail is sent after vxrecover executes. OPTIONS
-o The -o option and its argument are passed directly to vxrecover if vxrecover is called. This allows specifying -o slow[=iodelay] to keep vxrecover from overloading a busy system during recovery. The default value for the delay is 250 milliseconds. -O Reverts back to an older version. Specifying -O VxVM_version directs vxrelocd to use the relocation scheme in that version. -s Before vxrelocd attempts a relocation, a snapshot of the current configuration is saved in /etc/vx/saveconfig.d. This option specifies the maximum number of configurations to keep for each diskgroup. The default is 32. Mail Notification By default, vxrelocd sends mail to root with information about a detected failure and the status of any relocation and recovery attempts. To send mail to other users, add the user login name to the vxrelocd startup line in the startup script /sbin/init.d/vxvm-recover, and reboot the system. For example, if the line appears as: nohup vxrelocd root & and you want mail also to be sent to user1 and user2, change the line to read: nohup vxrelocd root user1 user2 & Alternatively, you can kill the vxrelocd process and restart it as vxrelocd root mail_address, where mail_address is a user's login name. Do not kill the vxrelocd process while a relocation attempt is in progress. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed log plexes: plexname ... failing disks: medianame ... failed subdisks: subdiskname ... The Volume Manager will attempt to find spare disks, relocate failed subdisks and then recover the data in the failed plexes. The medianame list under failed disks specifies disks that appear to have completely failed; the medianame list under failing disks indi- cates a partial disk failure or a disk that is in the process of failing. When a disk has failed completely, the same medianame list appears under both failed disks and failing disks. The plexname list under failed plexes shows plexes that were detached due to I/O fail- ures that occurred while attempting to do I/O to subdisks they contain. The plexname list under failed log plexes indicates RAID-5 or DRL (dirty region logging) log plexes that have failed. The subdiskname list specifies subdisks in RAID-5 volumes that were detached due to I/O errors. Spare Space A disk can be marked as ``spare.'' This makes the disk available as a site for relocating failed subdisks. Disks that are marked as spares are not used for normal allocations unless you explicitly specify them. This ensures that there is a pool of spare space available for relocating failed subdisks and that this space does not get consumed by normal operations. Spare space is the first space used to relocate failed subdisks. However, if no spare space is available, or the available spare space is not suitable or sufficient, free space is also used except for those marked with the nohotuse flag. See the vxedit(1M) and vxdiskadm(1M) manual pages for more information on marking a disk as a spare or nohotuse. Nohotuse Space A disk can be marked as ``nohotuse.'' This excludes the disk from being used by vxrelocd, but it is still available as free space. See the vxedit(1M) and vxdiskadm(1M) manual pages for more information on marking a disk as a spare or nohotuse. Replacement Procedure After mail is sent, vxrelocd relocates failed subdisks (those listed in the subdisks list). This requires finding appropriate spare or free space in the same disk group as the failed subdisk. A disk is eligible as replacement space if it is a valid Veritas Volume Manager disk (VM disk) and contains enough space to hold the data contained in the failed subdisk. If no space is available on spare disks, the relocation uses free space that is not marked nohotuse. To determine which of the eligible disks to use, vxrelocd first tries the disk that is closest to the failed disk. The value of ``close- ness'' depends on the controller, target, and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; a disk under the same target as the failed disk is closer than one under a different target. vxrelocd moves all subdisks from a failing drive to the same destination disk if possible. If no spare or free space is found, mail is sent explaining the disposition of volumes that had storage on the failed disk: Hot-relocation was not successful for subdisks on disk dm_name in volume v_name in disk group dg_name. No replacement was made and the disk is still unusable. The following volumes have storage on medianame: volumename ... These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the disk failure, the following message is included: The following volumes: volumename ... have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. These volumes must have their data restored. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included: The following RAID-5 volumes: volumename ... had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. These RAID-5 volumes must have their data restored. If there is spare space available, a snapshot of the current configuration is saved in /etc/vx/saveconfig.d/dg_name.yymmdd_hhmmss.mpvsh before attempting a subdisk relocation. Relocation requires setting up a subdisk on the spare or free space not marked with nohotuse and using it to replace the failed subdisk. If this is successful, the vxrecover command runs in the background to recover the data in volumes that had storage on the disk. If the relocation fails, the following message is sent: Hot-relocation was not successful for subdisks on disk dm_name in volume v_name in disk group dg_name. No replacement was made and the disk is still unusable. If any volumes (RAID-5 or otherwise) become unusable due to the failure, the following message is included: The following volumes: volumename ... have data on dm_name but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. These volumes must have their data restored. If the relocation procedure was successful and recovery has begun, the following mail message is sent: Volume v_name Subdisk sd_name relocated to newsd_name, but not yet recovered. After recovery completes, a mail message is sent relaying the result of the recovery procedure. If the recovery is successful, the follow- ing message is included in the mail: Recovery complete for volume v_name in disk group dg_name. If the recovery was not successful, the following message is included in the mail: Failure recovering v_name in disk group dg_name. Disabling vxrelocd If you do not want automatic subdisk relocation, you can disable the hot-relocation feature by killing the relocation daemon, vxrelocd, and preventing it from restarting. However, do not kill the daemon while it is doing the relocation. To kill the daemon, run the command: ps -ef from the command line and find the two entries for vxrelocd. Execute the command: kill -9 PID1 PID2 (substituting PID1 and PID2 with the process IDs for the two vxrelocd processes). To prevent vxrelocd from being started again, you must comment out the line that starts up vxrelocd in the startup script /sbin/init.d/vxvm-recover. FILES
/sbin/init.d/vxvm-recover The startup file for vxrelocd. /etc/vx/saveconfig.d/dg_name.yymmdd_hhmmss.mpvsh File where vxrelocd saves a snapshot of the current configuration before performing a relocation. SEE ALSO
kill(1), mailx(1), ps(1), vxdiskadm(1M), vxedit(1M), vxintro(1M), vxnotify(1M), vxrecover(1M), vxsparecheck(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxrelocd(1M)
All times are GMT -4. The time now is 11:20 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy