Sponsored Content
Operating Systems Solaris Setting up bootblock on RAID 0 SVM Post 302445795 by hergp on Tuesday 17th of August 2010 01:29:36 AM
Old 08-17-2010
Keepcase,

in a raid 1 (no matter how many disks you have in it), every subdisk (diskslice) is identical to the others and to the raidset itself. Therefore every subdisk in a raid 1 has the full information of the filesystem built on top of the raidset. As long as you do not update the filesystem (mount it read/write), you can use a subdisk instead of the raidset without messing things up.

What happens when the system boots (from a ufs root filesystem) is this:
The OBP reads the bootblock from one of the disks (the details are configured in the OBP), then the bootblock loads a secondary bootloader called ufsboot, which loads the kernel and essential drivers. Later, when the kernel has enough information to understand mirrored disks, it switches from using the subdisk to the mirrored logical volume for the root filesystem.

When the root filesystem is scattered over more than one disk, all this is not possible (at least as long as OBP has no builtin means to understand logical volumes).

I hope, this helps to shed some light on the boot process with logical volumes.
 

9 More Discussions You Might Find Interesting

1. Solaris

How do you remove a RAID 5 under SVM?

I have this setup, i can only find docs to unmirror a raid 1 set, how do you get rid of a raid 5 set? the same way? metadetach and metaclear? d8: RAID State: Okay Interlace: 32 blocks Size: 142245693 blocks (67 GB) Original device: Size: 142247872 blocks (67 GB) ... (2 Replies)
Discussion started by: BG_JrAdmin
2 Replies

2. Solaris

RAID controller needed for SVM?

hi this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network) i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
Discussion started by: Landser
4 Replies

3. Solaris

How can i grow Raid 5 volume in SVM..?

Hello experts.. How can i grow Raid 5 volume in SVM? Thanks in advance.. (2 Replies)
Discussion started by: younus_syed
2 Replies

4. Solaris

What is mirror and sub mirror in RAID -1 SVM

Hi , I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through metainit d51 1 1 c0t0d0s2 metainit d52 1 1 c1t0d0s2 In the next step metainit d50 -m d51 d50: Mirror is setup next step is metaattach d50 d52 d50 : submirror d52 is... (7 Replies)
Discussion started by: vr_mari
7 Replies

5. Solaris

Installing Solaris 8 bootblock without Solaris Install CD

Hello everyone, Background: I'm having an issue with booting a clone of hard drive with Solaris 8 installation. For cloning process I have used g4l, running under click'n'clone option. As far as I know the actual operation ran behind g4l's interface was dd, though I do not have any information... (12 Replies)
Discussion started by: johnny994
12 Replies

6. Linux

Help Setting up Linux Raid Server

I just built a home computer with 3TB hard drives I wanted to set up in a RAID 5 and load Ubuntu server onto it. The first thing I did was set up the drives in a RAID 5 using just the motherboard chipset software to do it, so a 'hardware' RAID basically. I installed Windows first to see if... (2 Replies)
Discussion started by: lorewap3
2 Replies

7. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
saconfig(1M)															      saconfig(1M)

NAME
saconfig - Command Line Configuration Utility for the HP SmartArray RAID Controller Family SYNOPSIS
<device_file> <device_file> -N <device_file> -R <RAID_level> [-S <stripe_size>] -p <physical_drive_id> [-p <physical_drive_id> ...] [-s <physical_drive_id>] [-c <capac- ity>] <device_file> -e <low|medium|high> <device_file> -r <low|medium|high> <device_file> -P <default|shortest|longest> <device_file> -A <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s all <device_file> -D <logical_drive_num> <device_file> -D all <device_file> -C <read_caching_percentage> <device_file> -F on <device_file> -F off <device_file> -I -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -I -l <logical_drive_num> <device_file> -E <logical_drive_num> -c <capacity> <device_file> -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] <device_file> -M <logical_drive_num> -S <stripe_size> DESCRIPTION
The command is a command line configuration tool for the HP SmartArray RAID Controller Family. This command provides the ability to create a logical drive, add a spare drive to existing logical drive, display configuration, delete a logical drive, and clear configuration. This command also enables the cache when it is used to create the first logical drive on the SmartArray RAID Controller. Furthermore it allows the option of changing the percentage of total cache size used for read caching and write caching. The auto-fail missing disks at boot fea- ture can be enabled or disabled using this command. Prerequisites needs to be able to create the /tmp/saconfig.lock file when it starts executing. This prevents multiple users from running This lock file is removed when exits. Security Restrictions requires either the superuser privilege or and privileges. See privileges(5) for more information about privileged access on systems that support fine-grained privileges. Options recognizes the following options and parameters as indicated in the SYNOPSIS section above. <device_file> To specify the device file for the SmartArray RAID Controller. The device file is as displayed by the command for the appropriate SmartArray RAID Controller. With no other options, displays size and status for all physical drives and RAID level, size, and status for all logical drives. With the option saconfig displays size and status for all physical drives and RAID level, size, and status for all logical drives. But the persistent device files (see intro(7)) will be displayed as against legacy device files in the absence of this option. -R <RAID_level> To create a logical drive with the specified RAID level. The supported RAID levels are 0, 1, 1+0, 5, and ADG. The lowest logical drive number not already in use will be given to the newly created logical drive, starting from 0. To determine the hardware path and device file for the logical drive, use the command. The logical drives are dis- played in the same order as in the output. RAID 1+0 logical drive requires even number of physical drives (minimum of 2). To achieve optimal fault tolerance, it is best to specify the same number of physical drives per channel if possible when creating a RAID 1+0 logical drive. This ensures the physical drives in each mirrored pairs would be on different channels. -S <stripe_size> To specify the stripe size for the logical drive to be created. The supported stripe sizes are 8, 16, 32, 64, 128, and 256 (KB). 128 and 256 stripe sizes are not available for RAID 5 or ADG logical drive. If this option is not used to specify the stripe size, default stripe size will be used to create the logical drive. For RAID 0 and 1+0 logical drive, the default size is 128. For RAID 5 and ADG logical drive, the default size is 16. -p <physical_drive_id> To specify the SCSI physical disk. It can be represented as <channel_id>:<target_id> (e.g., 4:12). Valid channel numbers are between 1 and 4. Valid target numbers are between 0 and 15. To specify the SAS/SATA physical disk. It can be represented as either <connector>:<enclosure>:<bay> (e.g., 2I:1:10) or <wwid> (e.g., 0x500000e010f16432). -s <physical_drive_id> To specify a spare drive to be included in the logical drive configuration. Refer <physical_drive_id> to -p option. -c <capacity> To specify the size in GB of a logical drive to be created. -A <logical_drive_num> To specify which logical drive to add spare drive to. -e <low | medium | high> To change the expand priority of controller to one of Low, Medium, High. When there are no logical drives, expand priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subse- quent logical drive creation will change the expand priority value of the controller to medium. -r <low | medium | high> To change the rebuild priority of controller to one of Low, Medium, High. When there are no logical drives, rebuild priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subsequent logical drive creation will change the rebuild priority value of the controller to high. -P <default | shortest | longest> To change the path selection method by the controller firmware. If it is set to default, firmware will select the Active path on its own. If the selection method is set to shortest, firmware will select the shortest path as the Active Path. If the path selection method is longest, firmware will select the longest path as the Active Path. All multi path configurations are Active-Standby configurations. -D <logical_drive_num> -s <physical_drive_id> To delete the spare drive from the specified logical drive. -D <logical_drive_num> -s all To delete all of spare drives from the specified logical drive. -D <logical_drive_num> To delete the specified logical drive. -D all To clear configuration. -C <read_caching_percentage> To specify the percentage of total cache size to be used for read caching. The remaining percentage will be used for write caching. Valid read caching percentage numbers are 0, 25, 50, 75, and 100 (%). -F on To enable auto-fail missing disks at boot feature. -F off To disable auto-fail missing disks at boot feature. -I -p <physical_drive_id> [-p <physical_drive_id> ...] To identify SAS/SATA physical drive(s) by LED. -I -l <logical_drive_num> To identify a SAS/SATA logical drive by LED. -E <logical_drive_num> -c <capacity> To extend the capacity of the specified logical drive up to larger capacity. The capacity is in GB. -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] To expand the specified logical drive and others in an array by physical drive(s). -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] To perform RAID level [with stripe size] migration on the specified logical drive. The stripe size is in KB. -M <logical_drive_num> -S <stripe_size> To perform stripe size migration on the specified logical drive. The stripe size is in KB. Logical Drive State Definitions All physical disks in the logical drive are operational. Some possible causes: Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive have failed. One or more disks in a RAID 0 logical drive have failed. Cache data loss has occurred. Array expansion was aborted. The logical drive is temporarily disabled because another logical drive on the controller had a missing disk at power-up. Also known as "degraded" state. A physical disk in a fault tolerant logical drive has failed. For RAID 1, 1+0 or 5, data loss may result if a second disk should fail. For RAID ADG, data loss may result if two additional disks should fail. A replacement disk is present, but rebuild hasn't started yet (another logical drive may be currently rebuilding). The logical drive will also return to this state if the rebuild had been aborted due to unrecoverable read errors from another disk. One or more physical disks in this logical drive are being rebuilt. While the logical drive was in a degraded state, the system was powered off and a disk other than the failed disk was replaced. Shut off the system and replace the correct (failed) disk. While the system was off, one or more disks were removed. Note: the other logical drives are held in a temporary "failed" state when this occurs. The data in the logical drive is being reorganized because: Physical disks have been added to the array (capacity expansion). The stripe size is being changed (stripe-size migration). The RAID level is being changed (RAID-level migration). A capacity expansion operation is in progress (or is queued up) that will make room on the disks for this new logical drive. Until room has been made on the physical disks, this newly configured logical drive cannot be read or written. The logical drive is waiting to undergo data reorganization (see EXPANDING above). Possible causes for the delay are a rebuild or expansion operation may already be in progress. Physical Disk State Definitions The physical disk is configured in one or more logical drives and is operational. The physical disk is configured as a spare disk. The physical disk has not been configured in any logical drives. The configured physical disk has failed. Return Value returns the following values: Successful completion. Command line syntax error. Incompatible CISS driver API. Failure opening a file. Other error. Examples To display configuration on the SmartArray RAID Controller /dev/ciss5 - To create a RAID 1+0 logical drive to include physical drives 4:0 and 4:1 and spare drive 4:2 - -R -p -p -s To create a RAID ADG logical drive with stripe size 64 to include physical drives 1:2, 2:2, 3:2 and 4:2 - -R -S -p -p -p -p To create a RAID 5 logical drive with capacity 45 GB to include SAS physical drives 1I:1:16, 1I:1:15, and 1I:1:14 - -R -c -p -p -p To set the expand priority of logical drives on a controller to medium -e To set the rebuild priority of logical drives on a controller to high -r To add spare drive 1:0 to logical drive 1 - -A -s To delete spare drive 1:0 from logical drive 1 - -D -s To delete all spare drives from logical drive 1 - -D -s To delete logical drive 0 - -D To clear configuration - -D To change read caching percentage to 75% - -C To extend logical drive 2 upto 45 GB in capacity - -E -c To expand logical drive 0 with 2 SAS physical drives - -E -p -p To migrate logical drive 2 with stripe 32 - -M -S To migrate logical drive 2 to RAID level 5 with stripe 64 - -M -R -S AUTHOR
was developed by HP. FILES
Executable file. saconfig lock file. Device files. SEE ALSO
sautil(1M), privileges(5), intro(7). saconfig(1M)
All times are GMT -4. The time now is 02:11 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy