Played with it for a while, installed second LDom and found that the two LDoms can see each other but none can talk to the control (primary) domain. It must have something to do with the virtual switch I guess.
Here are the interfaces:
Code:
root@krikkit ~ # ifconfig -a
lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1
inet 127.0.0.1 netmask ff000000
e1000g0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2
inet 192.168.140.210 netmask ffffff00 broadcast 192.168.140.255
ether 0:3:ba:d8:e0:94
And here are all the interfaces found by the primary domain:
Code:
root@krikit ~ # dladm show-dev
vsw0 link: up speed: 100 Mbps duplex: full
vsw1 link: up speed: 100 Mbps duplex: full
e1000g0 link: up speed: 100 Mbps duplex: full
e1000g1 link: up speed: 100 Mbps duplex: full
e1000g2 link: unknown speed: 0 Mbps duplex: half
e1000g3 link: unknown speed: 0 Mbps duplex: half
I tried to "plumb" and "up" the vsw0 device, even give it a new address but that made no difference.
What interfaces do you guys use in the control (primary) domain? The physical e1000g0 (or what's there on your systems) or some virtual ldm interfaces? How do you configure them?
I have a Netra T5220 Solaris 10 server with LDoms installed and enabled. RAID1 is enabled in the control domain with the following slices:
d50 -m d51 d52 1
d51 1 1 c1t0d0s5
d52 1 1 c1t1d0s5
d10 -m d11 d12 1
d11 1 1 c1t0d0s0
d12 1 1 c1t1d0s0
d20 -m d21 d22 1
d21 1 1 c1t0d0s1
d22 1 1... (14 Replies)
We're just about to migrate a large application from an Enterprise 6900 to a pair of T5220s utilising LDOMs. Does anyone have any experience of LDOMs on this kit and can provide any recommendations or pitfalls to avoid?
I've heard that use of LDOMs can have an impact on I/O speeds as it's all... (9 Replies)
Hi,
I develop simple animation ping script on Solaris Platform. It is like Cisco ping.
Examples and source code are below.
bash-3.00$ gokcell 152.155.180.8 30
Sending 30 Ping Packets to 152.155.180.8
!!!!!!!!!!!!!.!!!!!!!!!!!!!!!.
% 93.33 success... % 6.66 packet loss...... (1 Reply)
Hi
I am using perl to ping a list of nodes - with script below :
$p = Net::Ping->new("icmp");
if ($p->ping($host,1)){
print "$host is alive.\n";
}
else {
print "$host is unreacheable.\n";
}
$p->close();... (4 Replies)
I have a T4-1 with Solaris 11.1, LDom ver 3.0.0.1 and I'm encountering two problems with zones.
I'd greatly appreciate help on these, especially the first one.
I have created multiple guest LDoms, all Solaris 11.1, and they all work fine.
The first problem is that I can not boot any... (9 Replies)
Hi all,
New to this forum.
I have just been reading through a historical thread about some issues with IPMP.
Some tips from "Peasant" where very useful. Please see below
"Just couple of more hints regarding VM.
For VDS, use one VDS - one guest LDOM, don't put everything in primary-vds.... (9 Replies)
help with bash script!
im am working on this script to make sure my server will stay online, so i made this script..
HOSTS="192.168.138.155"
COUNT=4
pingtest(){
for myhost in "$@"
do
ping -c "$COUNT" "$myhost" &&return 1
done
return 0
}
if pingtest $HOSTS
#100% failed... (4 Replies)
If I do ldm ls l ldom1 the memory block is as follows:-
MEMORY
RA PA SIZE
0x20000000 0x20000000 64G
0x1420000000 0x1020000000 16G
0x1c20000000 0x1420000000 16G
0x2420000000 0x1820000000 16G
0x2c20000000... (1 Reply)
System: SPARC S7-2 Server; 2x8-core CPUs; 128Gb RAM; 2x600Gb HDD.
I have been experimenting on the above system, using ldmp2v to create "clones" of my physical systems as LDoms on the server when there was an unscheduled power outage. After the system came back up I had lost my LDoms, although... (7 Replies)
Discussion started by: apmcd47
7 Replies
LEARN ABOUT CENTOS
ocf_pacemaker_ping
OCF_PACEMAKER_PING(7) Pacemaker Configuration OCF_PACEMAKER_PING(7)NAME
ocf_pacemaker_ping - node connectivity
SYNOPSIS
[OCF_RESKEY_pidfile=string] [OCF_RESKEY_dampen=integer] [OCF_RESKEY_name=string] [OCF_RESKEY_multiplier=integer]
[OCF_RESKEY_host_list=string] [OCF_RESKEY_attempts=integer] [OCF_RESKEY_timeout=integer] [OCF_RESKEY_options=string]
[OCF_RESKEY_failure_score=integer] [OCF_RESKEY_debug=string] ping [start | stop | reload | monitor | meta-data | validate-all]
DESCRIPTION
Every time the monitor action is run, this resource agent records (in the CIB) the current number of ping nodes the host can connect to. It
is essentially the same as pingd except that it uses the system ping tool to obtain the results.
SUPPORTED PARAMETERS
OCF_RESKEY_pidfile = string [/ping-]
PID file
OCF_RESKEY_dampen = integer [5s]
Dampening interval
The time to wait (dampening) further changes occur
OCF_RESKEY_name = string [pingd]
Attribute name
The name of the attributes to set. This is the name to be used in the constraints.
OCF_RESKEY_multiplier = integer []
Value multiplier
The number by which to multiply the number of connected ping nodes by
OCF_RESKEY_host_list = string []
Host list
The list of ping nodes to count.
OCF_RESKEY_attempts = integer [2]
no. of ping attempts
Number of ping attempts, per host, before declaring it dead
OCF_RESKEY_timeout = integer [2]
ping timeout in seconds
How long, in seconds, to wait before declaring a ping lost
OCF_RESKEY_options = string []
Extra Options
A catch all for any other options that need to be passed to ping.
OCF_RESKEY_failure_score = integer []
failure_score
Resource is failed if the score is less than failure_score. Default never fails.
OCF_RESKEY_debug = string [false]
Verbose logging
Enables to use default attrd_updater verbose logging on every call.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 06/10/2014 OCF_PACEMAKER_PING(7)